• Title/Summary/Keyword: mutual impedance

Search Result 96, Processing Time 0.026 seconds

Evaluation of Measurement Accuracy of Ground Impedances in Counterpoise according to Location of Auxiliary Electrodes (보조전극의 위치에 따른 매설지선의 접지임피던스 측정정확도의 평가)

  • Lee, Bok-Hee;Choi, Young-Chul;Choi, Jong-Hyuk;Kim, Dong-Kyu;Lee, Gyu-Sun;Yang, Soon-Man;Kim, Tae-Gi
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.352-355
    • /
    • 2009
  • The ground resistance has been used as a method of estimating the capability of counterpoise. When transient currents blow through a ground electrode, it is reasonable to evaluate the performance of ground electrode system as a ground impedance instead of ground resistance. However, the measurement method of ground impedance for counterpoise is not clearly presented. This paper describes the measurement method of ground impedance considering the earth mutual resistances and AC mutual coupling. When we measure the ground impedance, the error due to earth mutual resistances depends on the distance between the auxiliary electrodes and the electrode under test. The measurement accuracy of high frequency ground impedance is mainly influenced by the location of the current electrode and the potential electrode.

  • PDF

Calculation of Radiation Impedance for Piston Sources on a Spherical Baffle (구형 배플상의 피스톤 음원에 대한 방사임피던스 계산)

  • 박순종;김무준;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.1
    • /
    • pp.54-60
    • /
    • 2003
  • The characteristics of radiation impedance for piston source on a spherical baffle are analyzed by algorithms which consists of Finite Element Method (FEM) and Hybrid type Infinite Element Method (HIEM). The results of self-radiation impedance for radiation angle and mutual radiation impedance between piston sources coincided with other reports on the spherical rigid baffle. For the spherical non-rigid baffles, the variations of self-radiation impedance and mutual-radiation impedance are identified. Therefore, these results can be applied to design and radiation characteristics analysis of acoustic transducers.

Online Parameter Estimation for Wireless Power Transfer Systems Using the Tangent of the Reflected Impedance Angle

  • Li, Shufan;Liao, Chenglin;Wang, Lifang
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.300-308
    • /
    • 2018
  • An online estimation method for wireless power transfer (WPT) systems is presented without using any measurement of the secondary side or the load. This parameter estimation method can be applied with a controlling strategy that removes both the receiving terminal controller and the wireless communication. This improves the reliability of the system while reducing its costs and size. In a wireless power transfer system with an LCCL impedance matching circuit under a rectifier load, the actual load value, voltage/current and mutual inductance can be reflected through reflected impedance measuring at the primary side. The proposed method can calculate the phase angle tangent value of the secondary loop circuit impedance via the reflected impedance, which is unrelated to the mutual inductance. Then the load value can be determined based on the relationships between the load value and the secondary loop impedance. After that, the mutual inductance and transfer efficiency can be computed. According to the primary side voltage and current, the load voltage and current can also be detected in real-time. Experiments have verified that high estimation accuracy can be achieved with the proposed method. A single-controller based on the proposed parameter estimation method is established to achieve constant current control over a WPT system.

A Study on Electrified Railway Traction System Impedance Calculation (전철선로 임피던스계산에 관한 연구)

  • Lee, Chon-Bae;Kim, Wang-Gon;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1407-1412
    • /
    • 2004
  • Impedance calculations of electric railway traction systems is essential to define characteristics and to design it. The self impedance is defined voltage drop rate per unit length, the mutual impedance is represented as a voltage induced to transmission line from transmission line. The self and the mutual impedance are influenced by ground return currents. The earth is considered as a semi-infinitely extended non-ideal conductor. The current of transmission line produces earth current induced magnetically and it flow through a path having minimum impedance. Carson proposed the impedance calculation formula using wave equations and magnetic field equations. Though the formula have an improper equation, that is still used as a standard impedance calculation method. This paper introduced an impedance calculation method that the complex depth of earth return method assumes that the current in conductor returns through an imagined earth depth path located directly under original conductor at a depth of. In this paper, we showed that this proposed method has a closed form and is easier than Carson's.

  • PDF

A Study of Radiation Current on Linear Antennas According to Mutual Impedance (상호Impedance에 의한 선형안테나상의 전류분포에 관하여)

  • 황인종
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.4 no.4
    • /
    • pp.22-27
    • /
    • 1967
  • The general mutual impedance expression for two staggered parallel, centerfed, linear antennas of unequal length and confirmed that the general expression being applied to a special case, reduced to the equation presented by other. Furthermore, calculation is done for a special cast, and it is confirmed that the general mutual impedance expression is applicable to the calculation of radiative curreut distribution on antenna system given above.

  • PDF

A New Distance Relaying Algorithm Immune to Mutual Coupling Effect and Reactance Effect for 765kV Untransposed Parallel Transmission Lines (상호결합효과와 리액턴스효과를 제거한 765kV 비연가 송전선로 보호용 거리계전 알고리즘)

  • Ahn Yong-Jin;Kang Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.1
    • /
    • pp.25-30
    • /
    • 2005
  • An accurate digital distance relaying algorithm which is immune to mutual coupling effect and reactance effect of the fault resistance and the load current for the line faults in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-ground fault and phase-to-phase short fault use a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

Effects of Ac Mutual Coupling According to Location of Auxiliary Electrodes In Measuring the Ground Impedance of Vertically or Horizontally Buried Ground Electrode (수직 또는 수평으로 매설된 접지전극의 접지임피던스 측정시 보조전극 위치에 따른 전자유도의 영향)

  • Choi, Young-Chul;Choi, Jong-Hyuk;Lee, Bok-Hee;Jeon, Duk-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.8
    • /
    • pp.86-92
    • /
    • 2009
  • In order to minimize ac mutual coupling, the auxiliary electrode are located at a right angle in measuring ground impedance. In case that the measurement space is limited, the alternative method is employed. At that time, it is necessary to investigate the measurement errors due to ac mutual coupling and earth mutual resistance in measuring the ground impedances. 'This paper presents the measurement accuracy according to the location of the current and potential auxiliary electrodes in measuring ground impedance of vertically or horizontally buried ground electrode. The measurement errors due to ac mutual coupling were evaluated Consequently, the effect of ac mutual coupling on the measurement accuracy for horizontally buried ground electrode is greater than that for vertically buried ground electrode. Measurement errors due to ac mutual coupling is the largest when the current and potential auxiliary electrodes are located in parallel. The 61.8[%] rule is inappropriate in measuring ground measurement. Theoretically, in case that the angle between the current and potential auxiliary electrodes is 90$[^{\circ}]$, there is no ac mutual coupling. If it is not possible to route the current and potential auxiliary electrodes at a right angle with limitation of measurement space, the location of these electrodes with an obtuse angle is preferred to that with an acute angle in reducing the measurement errors due to ac mutual coupling.

Calculation of Self-radiation Impedance for a Rectangular Transducer (장방형 트랜스듀서의 자기방사 임피던스 계산)

  • 이기욱;김무준;하강열;김천덕
    • The Journal of the Acoustical Society of Korea
    • /
    • v.19 no.7
    • /
    • pp.85-89
    • /
    • 2000
  • In this paper, by extending the previously developed self- and mutual-radiation impedance calculation method for a regular-square vibrating surface by using numerical series, we proposed a method to obtain the self-radiation impedance of a rectangular transducer with an arbitrary integer ratio of the length to width. The proposed method exhibits high accuracy and a short computation time. After investigating the accuracy and computation time as the number of elements changes, we have calculated the self-radiation impedance of several rectangular transducers, and compared the results with those in the literature.

  • PDF

A Study on Adaptive Distance Protection of Double-circuit Line with Mutual Impedance and Fault Resistance (2회선 송전선로에서 상호임피던스와 고장저항을 고려한 거리계전기의 동작 특성 연구)

  • Lee, Won-Seok;Jung, Chang-Ho;Lee, Jun-Kyong;Kim, Jin-O
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.317-319
    • /
    • 2003
  • This paper describes an adaptive distance relay for double-circuit line protection with mutual impedance and fault resistance. Double-circuit lines have two operating condition; both lines of a double-circuit line are in operation and one line is switched-off and both ends of the line are grounded. For optimal distance protection, the trip region is calculated, which have respect to mutual impedance and fault resistance.

  • PDF

A Distance Relaying Algorithms Immune to Reactance Effect for Double-Circuit Transmission Line Systems (리액턴스 효과를 최소한 병행 2회선 송전선로 보호 거리계전 알고리즘)

  • 안용진;강상희;이승재
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.1
    • /
    • pp.38-44
    • /
    • 2001
  • For double-circuit transmission line systems, an accurate digital distance relaying algorithm immune to the reactance effect is proposed. The apparent impedance calculated by the distance relay is influenced by the combined reactance effect of the fault resistance and the load current as well as the mutual coupling effect caused by the zero-sequence current of the adjacent parallel circuit. To compensate the magnitude and phase of the estimated impedance, this algorithm uses phase angle difference between the zero(positive) sequence of the both side of the system seperated by the fault point. The impedance measuring algorithm presented used a current distribution factor to compensate mutual coupling effect instead of the collected zero-sequence current of the adjacent parallel circuit.

  • PDF