• Title/Summary/Keyword: multistory buildings

Search Result 55, Processing Time 0.024 seconds

Drift Control for Multistory Moment Frames under Lateral Loading

  • Grigorian, Carl E.;Grigorian, Mark
    • International Journal of High-Rise Buildings
    • /
    • v.2 no.4
    • /
    • pp.355-365
    • /
    • 2013
  • The paper reports results of recent studies on the effects of column support conditions on the lateral displacements of moment frames at incipient collapse. The article presents a number of exercises in the plastic theory of structures that lead to useful design formulae. It has been shown that Drift Shifting (DS) is caused due to differences in the stiffnesses of adjoining columns, and that changes in drift ratios are more pronounced at first level column joints in both fixed as well as pinned base frames. In well proportioned moment frames, DS in the upper levels could be minimized, even reduced to zero. It has been demonstrated that DS can be eliminated in properly designed fixed and grade beam supported (GBS) moment frames. Several examples, including symbolic P-delta effects, have been provided to demonstrate the validity and the applications of the proposed ideas to the design and drift control of moment frames. The proposed methodology is exact within the bounds of the theoretical assumptions and is well suited for preliminary design and teaching purposes.

Study Improvement of the Evacuation Performance in a Double-Skin Structure (이중외피 구조 건축물의 피난성능 개선에 관한 연구)

  • Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.98-107
    • /
    • 2017
  • This study examined an effective way of measuring the evacuation performance in buildings, which are applied to a double skin facade through an evaluation of the escape safety. Buildings with a double skin facade appeared to have a faster combustion expansion speed for the upper floor if a fire occurs. Moreover, a double skin facade is more difficult to escape safely than a general building construction because of the limited design standards. Accordingly, this study suggested virtual modeling including single emergency stairs and alarm systems considering the risk in each structure of buildings. These results showed that box-type double skin, corridor access type, shaft-box type, and multistory facade systems showed a 26.4%, 29.1%, 23.4%, and 26.3% increase in evacuation performance, respectively, as well as securing the safety of occupants.

Behavior and Failure Mode of Steel Coupling Beams Joint with FBP (FBP가 설치된 철골 커플링보 접합부의 거동 및 파괴모드)

  • Song Han-Beom;Yi Waon-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.6 s.90
    • /
    • pp.1001-1009
    • /
    • 2005
  • The usefulness of walls in the structural planning of multistory buildings has long been recognized. When walls are situated in advantageous positions in a buildings, they can be very efficient in resisting lateral load. Specially coupled shear wall system is the primary lateral load resisting system of buildings. It is customary to refer to such walls as being 'coupled' by coupling beams. The coupling beams must exhibit excellent strength, stiffness ductility and energy dissipation capacity. To achieve these demands for steel coupling beam, steel coupling beam with Face Bearing Plate(FBP) embedded in the reinforced concrete walls is proposed. A comprehensive experimental test involving 2 steel coupling beam with and without FBP has been performed. Through experimental study, the evaluation of the advantage of that was establish and proposed the failure mode.

The Steel Coupling Beam-Wall Connections Strength

  • Park, Wan-Shin;Yun, Hyun-Do
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.135-145
    • /
    • 2006
  • In high multistory reinforced concrete buildings, coupled shear walls can provide an efficient structural system to resist horizontal force due to wind and seismic effects. Coupled shear walls are usually built over the whole height of the building and re laid out either as a series of walls coupled by beams and/or slabs or a central core structure with openings to accommodate doors, elevators walls, windows and corridors. A number of recent studies have focused on examining the seismic response of concrete, steel, and composite coupling beams. However, since no specific equations are available for computing the bearing strength of steel coupling beam-wall connections, it is necessary to develop such strength equations. There were carried out analytical and experimental studies to develop the strength equations of steel coupling beam-connections. Experiments were conducted to determine the factors influencing the bearing strength of the steel coupling beam-wall connection. The results of the proposed equations were in good agreement with both test results and other test data from the literature. Finally, this paper provides background for design guidelines that include a design model to calculate the bearing strength of steel coupling beam-wall connections.

Seismic behavior of steel frames with lightweight-low strength industrialized infill walls

  • Zahrai, Seyed Mehdi;Khalili, Behnam Gholipour;Mousavi, Seyed Amin
    • Earthquakes and Structures
    • /
    • v.9 no.6
    • /
    • pp.1273-1290
    • /
    • 2015
  • JK wall is a shear wall made of lightweight EPS mortar and reinforced with a 3-D galvanized steel mesh, called JK panel, and truss-like stiffeners, called JK stiffeners. Earlier studies have shown that low strength lightweight concrete has the potential to be used in structural elements. In this study, seismic contribution of the JK infill walls surrounded by steel frames is numerically investigated. Adopting a hybrid numerical model, behavior envelop of the wall is derived from the general purpose finite element software, Abaqus. Obtained backbone would be implemented in the professional analytical software, SAP2000, in which through calibrated hysteretic parameters, cyclic behavior of the JK infill can be simulated. Through comparison with earlier experimental results, it turned out that the proposed hybrid modeling can simulate monotonic and cyclic behavior of JK walls with good accuracy. JK infills have a panel-type configuration which their dominant failure mode would be ductile in flexure. Finally technical and economical advantages of the proposed JK infills are assessed for two representative multistory buildings. It is revealed that JK infills can reduce maximum inter-story drifts as well as residual drifts at the expense of minor increase in the developed base shear.

Kiln for Production of Light Weight Aggregate from Coal Fly Ash (Coal Fly Ash로부터 경량 골재 생산을 위한 소성장치)

  • Choi, Young-Yoon;Nam, Chul-Woo;Kim, Byoung-Gyu;Kim, Byoung-Gon
    • Resources Recycling
    • /
    • v.16 no.4
    • /
    • pp.61-67
    • /
    • 2007
  • In viewpoints of environmental and resource conservation, it is desirable to utilize fly ash generated from domestic coal power stations as light constructive material. Furthermore, the demand of light constructive materials has been increased as many building tend to become highly multistory buildings. In demonstration of converting fly ash to light constructive materials, the Dwight-Lloyd kiln of which the operation is relatively easy and the reliability very high has been informed to be only commercialized plant over the world. In this review, Dwight-Lloyd kiln plant operated at Oomura coal power station in Japan is explained. Circular grate kiln, Shaft kiln, Rotary kiln plants that are under developed is also introduced.

Application of numerical simulation for the analysis and interpretation of pile-anchor system failure

  • Saleem, Masood
    • Geomechanics and Engineering
    • /
    • v.9 no.6
    • /
    • pp.689-707
    • /
    • 2015
  • Progressive increase in population causing land scarcity, which is forcing construction industry to build multistory buildings having underground basements. Normally, basements are constructed for parking facility. This research work evaluates important factors which have caused the collapse of pile-anchor system at under construction five star hotel. 21 m deep excavation is carried out, to have five basements, after installation of 600 mm diameter cast in-situ contiguous concrete piles at plot periphery. To retain piles and backfill, soil anchors are installed as pit excavation is proceeded. Before collapse, anchors are designed by federal highway administration procedure and four anchor rows are installed with three strands per anchor in first row and four in remaining. However, after collapse, system is modeled and analyzed in plaxis using mohr-coulomb method. It is investigated that in-appropriate evaluation of soil properties, additional surcharge loads, lesser number of strands per anchor, shorter grouted body length and shorter pile embedment depth caused large deformations to occur which governed the collapse of east side pile wall. To resume work, old anchors are assumed to be standing at one factor of safety and then system is analyzed using finite element approach. Finally, it is concluded to use four strands per anchor in first new row and five strands in remaining three with increase in grouted and un-grouted body lengths.

Evaluation on the Deformation Capacity of RC Frame Structure with Strong Column-Weak Beam (강한 기둥-약한 보로 설계된 철근 콘크리트 골조구조의 변형성능 평가에 관한 연구)

  • Seo, Soo-Yeon;Lee, Li-Hyung;Chin, Se-Ok;Choi, Yun-Chul
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.4
    • /
    • pp.225-233
    • /
    • 2003
  • Recently, the concern for displacement-based design has been increased as a performance based design method in which the deformation capacity of structure becomes so important. In this paper, a process is presented to accurately evaluate the deformation capacity of multistory RC frame structure. In the calculation of drift of frame, the deformation of beam and column as well as the deformation of anchorage and joint are considered. From the comparison between previous test and calculation results, the usefulness of the process is verified. The proposed process is also applied to the multiple story RC frame buildings(5, 10, 15 stories) designed to have strong column-weak beam. The results showed that the deformation capacity of the buildings could be not properly evaluated when deformations of anchorage and joint were ignored.

New optimum distribution of lateral strength of shear-type buildings for uniform damage

  • Donaire-Avila, Jesus;Lucchini, Andrea;Benavent-Climent, Amadeo;Mollaioli, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • v.76 no.3
    • /
    • pp.279-291
    • /
    • 2020
  • The seismic design of conventional frame structures is meant to enhance plastic deformations at beam ends and prevent yielding in columns. To this end, columns are made stronger than beams. Yet yielding in columns cannot be avoided with the column-to-beam strength ratios (about 1.3) prescribed by seismic codes. Preventing plastic deformations in columns calls for ratios close to 4, which is not feasible for economic reasons. Furthermore, material properties and the rearrangement of geometric shapes inevitably make the distribution of damage among stories uneven. Damage in the i-th story can be characterized as the accumulated plastic strain energy (Wpi) normalized by the product of the story shear force (Qyi) and drift (δyi) at yielding. Past studies showed that the distribution of the plastic strain energy dissipation demand, Wpi/ΣWpj, can be evaluated from the deviation of Qyi with respect to an "optimum value" that would make the ratio Wpi/(Qyiδyi) -i.e. the damage- equal in all stories. This paper investigates how the soil type and ductility demand affect the optimum lateral strength distribution. New optimum lateral strength distributions are put forth and compared with others proposed in the literature.

A Study on the Energy Load of the Curtain Wall Buildings according to the Application of the Double-skin Facade System (커튼월 건축물의 이중외피 시스템 적용에 따른 에너지 부하량 검토)

  • Li, Bai-Hong;Lee, Jun-Gi;Kim, Sung-Hoon;Lee, Gab-Taek;Kim, Dong-Wan;Lee, Kyung-Hee
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.99-104
    • /
    • 2016
  • In this study, we researched the energy load according to the change of the inner window area ratio, the distance of the air gap and the azimuth of the curtain wall building, which installed the multistory double-skin facade(DSF). and we compared the results with the no double-skin facade situation as follows. With the DSF, it is better than other case, when the window area ratio is 40% and the air gap is 1.2m on the west, south-45-west, south-45-east and east. And it's best when the window area ratio is 40% and the air gap is 0.4m on the south. And on the east or south-45-east, the window area ratio is 40% and the air gap is 1.2m is better than other case with the DSF. On south, it is best when the window area ratio is 100% without DSF. On the south-45-west or west, it is best when the window area ratio is 40% without the DSF.