• 제목/요약/키워드: multistory building

검색결과 64건 처리시간 0.025초

Damage detection of multistory shear buildings using partial modal data

  • Shah, Ankur;Vesmawala, Gaurang;Meruane, V.
    • Earthquakes and Structures
    • /
    • 제23권1호
    • /
    • pp.1-11
    • /
    • 2022
  • This study implements a hybrid Genetic Algorithm to detect, locate, and quantify structural damage for multistory shear buildings using partial modal data. Measuring modal responses at multiple locations on a structure is both challenging and expensive in practice. The proposed method's objective function is based on the building's dynamic properties and can also be employed with partial modal information. This method includes initial residuals between the numerical and experimental model and a damage penalization term to avoid false damages. To test the proposed method, a numerical example of a ten-story shear building with noisy and partial modal information was explored. The obtained results were in agreement with the previously published research. The proposed method's performance was also verified using experimental modal data of an 8-DOF spring-mass system and a five-story shear building. The predicted results for numerical and experimental examples indicated that the proposed method is reliable in identifying the damage for multistory shear buildings.

Damage detection of mono-coupled multistory buildings: Numerical and experimental investigations

  • Xu, Y.L.;Zhu, Hongping;Chen, J.
    • Structural Engineering and Mechanics
    • /
    • 제18권6호
    • /
    • pp.709-729
    • /
    • 2004
  • This paper presents numerical and experimental investigations on damage detection of mono-coupled multistory buildings using natural frequency as only diagnostic parameter. Frequency equation of a mono-coupled multistory building is first derived using the transfer matrix method. Closed-form sensitivity equation is established to relate the relative change in the stiffness of each story to the relative changes in the natural frequencies of the building. Damage detection is then performed using the sensitivity equation with its special features and minimizing the norm of an objective function with an inequality constraint. Numerical and experimental investigations are finally conducted on a mono-coupled 3-story building model as an application of the proposed algorithm, in which the influence of modeling error on the degree of accuracy of damage detection is discussed. A mono-coupled 10-story building is further used to examine the capability of the proposed algorithm against measurement noise and incomplete measured natural frequencies. The results obtained demonstrate that changes in story stiffness can be satisfactorily detected, located, and quantified if all sensitive natural frequencies to damaged stories are available. The proposed damage detection algorithm is not sensitive to measurement noise and modeling error.

유럽 집합주택의 입면 디자인 요소에 관한 연구 - 1980년대 이후 사례를 중심으로 - (A Study on the Elevation and Facade Design Factors of European Multistory-Housing)

  • 김준래;전남일
    • 한국주거학회논문집
    • /
    • 제21권5호
    • /
    • pp.23-33
    • /
    • 2010
  • In the late twentieth century, the multistory housing has become the most preferred housing type. Moreover, in multistory housing design, not only interior design but also exterior design, uniqueness and characteristic have been added as significant factors in design to break simplicity and uniformity. The purpose of this study is to understand the tendency of the elevation design in Europe and to suggest the idea for elevation design for domestic. Also, each elements of elevation were analyzed through classification and schematization which categorized by its own characteristic. Design elements can be classified into three categories. They are corresponding with inner spaces, emphasizing visual expression of exterior material and texture, and presenting aesthetic factors of building shape. Those are named as the Spatial Externalization, the Visual Expression, and the Expression of Building Shape. In this frame nineteen elevations of sixteen different cases were analysed. As a result of case studies, it is clear that elevation designs were not standardized and each cases has its own characteristics. Also it showed how the each design elements can be coordinated as a total design and how they expressed identities of each housing. This study could contribute to motivate diversifying the design of multistory housing.

Experimental investigation on in-plane seismic behavior of multistory opening masonry walls with two different failure modes

  • Xin, Ren;Bi, Dengshan;Huang, Wei
    • Structural Engineering and Mechanics
    • /
    • 제84권4호
    • /
    • pp.479-488
    • /
    • 2022
  • Aiming to examine different failure patterns in multistory URM walls, two 1/3 scaled three-story and three-bay URM models were designed for the quasi-static loading tests to contrastively investigate the failure processes and characteristics of the multistory URM walls. Two different failure responses were observed with special attention paid to the behavior of spandrel-failure mode. By evaluating the seismic performance and deformation behavior of two test walls, it is demonstrated that spandrels, that haven't been properly designed in some codes, are of great significance in the failure of entire URM walls. Additionally, compared with pier-failure mode, spandrel-failure for multistory URM building is more reasonable and advisable as its effectively participation in energy dissipation and its efficiently improvement on seismic capacity and deformation in the overall structure. Furthermore, the experimental results are beneficial to improve seismic design and optimize reinforcement method of URM buildings.

SEISMIC RESPONSE OF MULTISTORY BUILDING STRUCTURES WITH FLEXIBLE FLOOR DIAPHRNGMS

  • Lee, Dong-Guen;Moon, Sung-Kwon
    • 전산구조공학
    • /
    • 제2권1호
    • /
    • pp.47-53
    • /
    • 1989
  • An efficient model for three-dimensional analysis of multistory structures with flexible floor diaphrgms is proposed in this paper. Three-dimensional analysis of a building structure using a finite element model requires tedious input data preparation, longer computation time, and larger computer memory. The model proposed in this study is developed by assembling a series of two-dimensional resisting systems and is considered to overcome the shortcomings of a three-dimensional finite element model without deteriorating the accuracy of analysis results. Static and dynamic analysis results obtained using the proposed model are in excellent agreement with those obtained using three-dimensional finite element models in terms of displacement, periods, and mode shapes. Effects of floor diaphragm flexibility on seismic response of multistory building structures are investigated.

  • PDF

고층건물의 내진설계에 미치는 중력하중의 영향 (Implications of the effects of gravity load for earthquake resistant design of multistory building structurtes)

  • 이동근;이석용
    • 전산구조공학
    • /
    • 제6권3호
    • /
    • pp.67-80
    • /
    • 1993
  • 본 연구에서는 지진에 대한 고층건물의 응답특성, 그리고 지진응답에 미치는 중력하중의 영향과 중력하중의 영향이 내진설계에 미치는 중요성을 산정하였다. 이를 위해서 예제 구조물에 대한 정적해석 및 지진하중에 대한 동적해석을 하였다. 지진에 대한 고층건물의 지진응답 특성을 파악하기 위하여 비탄성 변형의 건물 높이에 따른 분포를 알아보았다. 지진이 발생하면 휨모멘트 요구도가 건물의 상부층보다 하부층에서 상대적으로 더 많이 증가해서 설계모멘트와의 차이가 건물의 하부층으로 갈수록 더 커진다. 그 결과 현재 쓰이는 내진설계방법에 따라 설계된 예제 건물들은 지진에 대하여 비탄성 응답이 건물의 각 층마다 서로 다르게 발생하는데 주로 건물의 하부층에서 큰 비탄성 응답이 발생한다. 또한 설계시에 고려된 중력하중 때문에 구조적 손상이 건물의 꼭대기 층에서 아래로 갈수록 크게 증가한다. 구조물의 지진응답에 관하여 중력하중은 보의 항복시간을 앞당기며, 보의 양단의 소성힌지에 각기 다른 비탄성 거동을 유발시킨다. 그러나 중력하중에 의한 초기 휨모멘트의 영향은 보가 비탄성 거동을 계속함에 따라 재분배되어 보의 양단에서 그 영향이 감소되며 비탄성 변형이 계속되면 크게 감소한다. 중력하중에 의한 초기 휨모멘트의 영향이 감소는 고층건물의 내진설계에 있어서 중력하중의 영향이 주는 의미는 기둥과 보의 휨강도를 결정할 때 현재의 방법보다 중력하중의 영향을 줄이고 지진하중의 영향을 증가시켜야 한다는 것이다.

  • PDF

전단벽식 고층건물의 내진해석에 관한 연구 (A Study on the Improved Seismic Analysis of Multistory Shear Wall Buildings)

  • 이준교;이근홍;이수곤
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1993년도 가을 학술발표회 논문집
    • /
    • pp.267-272
    • /
    • 1993
  • Currently about 60 contries in the world require earthquake resistant structural design in case of multistory building constructions. In these cases the equivalent lateral force procedure is commonly adopted because of its simplicity and convenience. This procedure, however, is developed based mainly on the first vibration mode response of building structure. The dynamic analysis of tall building shows that the effect of higher modes of vibration on the response of the building can not be neglected. In this paper, the effect of higher modes of vibration on seismic response is evaluated through modal analysis of tall building structures. On the basis of evaluation results, an improved procedure is to be proposed for the extended application of the equivalent lateral force procedure.

  • PDF

고층건물의 효율적인 구조해석 (An Efficient Structural Analysis of Multistory Buildings)

  • 김경호;이동근
    • 대한토목학회논문집
    • /
    • 제7권2호
    • /
    • pp.141-153
    • /
    • 1987
  • 고층 건물의 정확한 거동을 구하기 위한 구조 해석은 컴퓨터 적용의 중요한 분야로 취급되어 왔다. 본 논문에서는 건축구조물에 대한 3차원적인 해석방법을 연구하였다. 이 해석 방법은 건물을 각각의 독립된 프레임의 조합체로 보고 해석하므로 매우 효율적이며, 건물의 3차원적인 거동에 관한 고려는 건물이나 하중이 대칭이 아닐 때는 특히 중요하다. 그리고 matrix condensation 기법을 이용함으로써 컴퓨터의 용량과 해석 시간이 상당히 절약되므로 매우 경제적이다. 본 논문의 건물 구조해석 컴퓨터 프로그램 PFS의 정확성과 효율성을 증명하기 위해 여러가지 예제들에 대해서 SAPIV 에 의한 해석 결과와 비교하였다. 그러므로, 본 논문에서 제안한 해석방법은 고층 건물의 구조 설계에서 매우 효율적이라 할 수 있다.

  • PDF

건축구조물의 시스템 연성요구도 평가를 위한 대표응답의 활용 (Responses of Equivalent SDOF System for System Ductility Demands Evaluation of Multistory Building Structures)

  • 최원호;이동근
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.446-453
    • /
    • 2001
  • System-level ductility is an essential parameter for seismic performance evaluation of multistory building structures. The ductility demands for single degree of freedom structures or individual structural members can be determined easily. However, there is no clearly established method to determine the ductility demands for structural systems. The system ductility demands are estimated in this study by the equivalent SDOF system methods and proposed method which used the representative responses obtained from the MDOF systems directly. And seismic performance of building structures is evaluated by the modified Capacity Spectrum Method using the representative responses, and the result was compared with those of the inelastic time history analysis.

  • PDF

Study on the Performance of Wireless Local Area Network in a Multistory Environment with 8-PSK TCM

  • Suwattana, Danai;Santiyanon, Jakkapol;Laopetcharat, Thawan;Charoenwattanaporn, Monton;Goenchanart, Ut;Malisuwan, Settapong
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.549-551
    • /
    • 2002
  • A Wireless Local Area Network (WLAN) is a flexible data communication system implemented as an extension to, or as an alternative for, a wired LAN with in a building or campus. However, communications in an indoor environment present problems not encountered in outdoor wireless communication systems. Since cellular type systems are interference limited, the indoor environment is more hostile than the outdoor environment due to the lower propagation constant. In this paper, the equation for the signal to interference ratio in a multistory building will be derived. Knowing the S/I ratio, the floor frequency reuse can be determined. Finally, the simulation in this research is designed to study the performance (BER) of WLAN system in the multistory environment by applying the 8-PSK Trellis Coded modulation technique. The procedure allows a quick evaluation of BER in Wireless LAN system due to the co-channel interference.

  • PDF