• 제목/요약/키워드: multistatic data

검색결과 6건 처리시간 0.019초

표적탐지성능을 이용한 다중상태 소나의 효과도 분석 (The Effectiveness Analysis of Multistatic Sonar Network Via Detection Peformance)

  • 장재훈;구본화;홍우영;김인익;고한석
    • 한국군사과학기술학회지
    • /
    • 제9권1호
    • /
    • pp.24-32
    • /
    • 2006
  • This paper is to analyze the effectiveness of multistatic sonar network based on detection performance. The multistatic sonar network is a distributed detection system that places a source and multi-receivers apart. So it needs a detection technique that relates to decision rule and optimization of sonar system to improve the detection performance. For this we propose a data fusion procedure using Bayesian decision and optimal sensor arrangement by optimizing a bistatic sonar. Also, to analyze the detection performance effectively, we propose the environmental model that simulates a propagation loss and target strength suitable for multistatic sonar networks in real surroundings. The effectiveness analysis on the multistatic sonar network confirms itself as a promising tool for effective allocation of detection resources in multistatic sonar system.

능동 소나 위치 추정 성능 비교 및 최적 수신망 배치 (Comparison of Active Sonar Target Positioning Performance and Optimal Sensor Arrangement)

  • 박치현;홍우영;고한석;김인익
    • 한국음향학회지
    • /
    • 제22권3호
    • /
    • pp.224-232
    • /
    • 2003
  • 본 논문에서는 능동 소나의 구성 방법 및 관측 오차에 따른 위치 추정 성능에 대해서 다룬다. 능동 소나는 구성 방법에 따라서 크게 단상태 (Monostatic) 소나, 양상태 (Bistatic) 소나, 다중상태 (Multistatic) 소나로 분류될 수 있으며, 각각의 오차에 대한 특성이 서로 다르다 각 수신기가 거리 정보와 방위 정보를 얻을 수 있다는 가정하에 단상태, 양상태 소나와 다중상태 소나의 위치 추정 성능에 대해 비교해 보고 기존의 정보 융합 방법인 최소 자승법 (LS: Least square)에 가중치를 주는 가중치 최소 지승법 (WLS: Weighted least square)을 제안하였다. 또한, 제안된 방법을 이용하여 수신기의 수, 송수신기간 거리와 위치 추정 성능과의 연관성에 대하여 알아보고 효과적인 다중상태 소나 배치에 대한 연구를 수행하였다. 모의 실험결과 다중상태 소나의 위치 추정 제곱근 오차평균이 단상태 소나에 비해 약 35.98%, 양상태 소나에 비해 약 37.45% 우수한 것을 볼 수 있었으며 WLS가 LS에 비해 평균 7.4% 우수한 성능을 나타내었고 각 센서에 입력되는 정보의 분산 차가 클수록 성능 향상율이 증가하는 경향을 보였다.

FM 방송 기반 멀티스태틱 PCL 시스템 원형 배열 안테나 보정을 위한 Array Manifold 측정 및 검증 (Array Manifold Measurement and Verification for UCA Calibration in Multistatic PCL System based on FM Broadcasting)

  • 박준식;심홍석;안준일;송규하
    • 한국군사과학기술학회지
    • /
    • 제24권2호
    • /
    • pp.165-174
    • /
    • 2021
  • This study describes a method of measurement and verification of array manifold of uniform circular array antenna applicable to multistatic Passive Coherent Location(PCL) system using FM broadcasting. In an environment of outdoor test where FM broadcast signals are scattered, array manifold measurement methods using network analyzer and multi-channel digital receiver are introduced. Also, the descriptions and solutions for the test limits of each measurement method and the considerations affecting the measurement accuracy are presented. In addition, to verify the validity of the measured array manifold, the gain and phase difference were compared with the array manifold data obtained by EM simulation, and the effectiveness and accuracy of the measured array manifolds were compared and analyzed by estimating the direction of arrival of the FM broadcast signal received from the multistatic PCL system.

Time-reversal microwave focusing using multistatic data

  • Won-Young Song;Soon-Ik Jeon;Seong-Ho Son;Kwang-Jae Lee
    • ETRI Journal
    • /
    • 제46권2호
    • /
    • pp.333-346
    • /
    • 2024
  • Various techniques for noninvasively focus microwave energy on lesions have been proposed for thermotherapy. To focus the microwave energy on the lesion, a focusing parameter, which is referred to as the magnitude and phase of microwaves radiated from an external array antenna, is very important. Although the finite-difference time-domain (FDTD)-based time-reversal (TR) focusing algorithm is widely used, it has a long processing time if the focusing target position changes or if optimization is needed. We propose a technique to obtain multistatic data (MSD) based on Green's function and use it to derive the focusing parameters. Computer simulations were used to evaluate the electric fields inside the object using the FDTD method and Green's function as well as to compare the focusing parameters using FDTD- and MSD-based TR focusing algorithms. Regardless of the use of Green's function, the processing time of MSD-based TR focusing algorithms reduces to approximately 1/2 or 1/590 compared with the FDTD-based algorithm. In addition, we optimize the focusing parameters to eliminate hotspots, which are unnecessary focusing positions, by adding phase-reversed electric fields and confirm hotspot suppression through simulations.

Multistatic Field또는 3차원 공용보상체를 사용한 유방의 방사선 조사법의 평가 (Improved Breast Irradiation Techniques Using Multistatic Fields or Three Dimensional Universal Compensators)

  • 한영이;조재호;박희철;추성실;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.24-33
    • /
    • 2002
  • 목적 : 유방보존 수술 후 행하는 방사선치료인 2문 대칭조사(two tangential field technique)시 나타나는 선량분포의 불균일성을 효과적으로 개선하기 위하여, multistatic fields의 사용법과 공용보상체 사용법을 제시하고 평가하였다. 대상 및 방법 : 1) Multistatic field 방법 3차원의 치료계획용 software (RTP)를 이용하여, wedge를 사용한 2문 대칭 조사의 최적의 치료계획을 시행한 후 beam's eye view상에서 과조사가 일어나는 부분을 가리워 주도록 blocked field를 설계하고, 그 beam에 대칭되는 beam을 만들었다. 기존의 2개의 tangential field와 추가된 field의 weighting을 최적의 선량분포를 갖도록 조절하였다. 2) 공용보상체 사용법 : 1999와 2000년에 본원에서 whole-breast radiotherapy를 받은 환자 20명의 유방의 크기를 측정하고 평균하여 표준 유방 모델을 만들었다. 이 모델에 대하여 공용보상체를 설계하고, 설계된 공용보상체의 geometry를 RTP에 입력한 후 환자의 치료 계획을 수행하였다. 2문 대칭조사 치료 계획과, multistatic fields의 경우 그리고 공용 보상체를 사용한 경우의 치료계획에서의 불균일도(DII : 처방선량의 $95-105\%$를 벗어나는 PTV의 부피의 백분율), 최대선량 값$(D_{max})$ 그리고 등가선량 곡선을 각각 비교하였다. 결과 : Multistatic field 방법은 DII의 평균값을 $14.6\%$ (p value<0.000) 낮추고 $D_{max}$$4.7\%$ (p value<0.000) 낮춤으로써, 전통적인 2문 대칭 조사법보다 우수한 방법으로 확인되었다. 반면에 공용보상체의 사용은 평균 DII를 $3.7\%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.

탄성파 피에조콘 관입 시험을 통한 국내 퇴적 지반의 전단파 속도 결정 (Determination of shear wave velocity profiles in soil deposit from seismic piezo-cone penetration test)

  • 선창국;정경자;정종홍;김홍종;조성민
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2005년도 제7회 특별심포지움 논문집
    • /
    • pp.125-153
    • /
    • 2005
  • 탄성파 피에조콘 관입 시험(SCPTU)은 동적 물성을 포함한 지반의 공학적 특성 평가에 가장 유용 한 조사 기법 중의 하나이다. 본 연구에서는 국내 지반에 대한 실질적 활용 연구로서 국내 대표적 퇴적지층 발달 지역인 부산과 인천을 대상으로 각각 두 부지와 네 부지에서 SCPTU를 수행하였다. 현장에서 SCPTU로부터 획득한 파형 신호에 대해 교차법을 이용한 신호 판독을 실시하여 깊이별 전단파의 초기 도달 시점 및 그에 따른 깊이별 도달 시차를 결정하였다. 이를 토대로 Snell의 법칙에 근간한 굴절 전파경로법을 이용하여 전단파 속도(VS) 주상도를 도출하였으며, 대체로 깊이별 VS 분포는 콘 선단 저항력(qt) 분포 경향과 유사하게 나타났다. 인천 지역에서는 병행된 일반적인 다운홀 탄성파 시험에 비해 SCPTU를 보다 깊은 심도까지 효율적으로 수행할 수 있었다. 이와 더불어, 일반적인 CPTU 자료의 지진공학적 활용을 목적으로 SCPTU로부터 측정된 결과를 토대로 VS와 콘 관입 특성값의 상관관계를 분석 도출하였다. 다중 회귀 분석을 수행하여 전단파 속도와 콘 관입 특성값 중 네가지의 독립변수인 콘 관입 저항력(qt), 주면 마찰력(fs), 유효상재응력($\sigma$'v0), 간극수압계수(Bq) 간의 상호 관련성을 정량적으로 평가하였으며, 특히 흙 분류 지수인 Ic 값에 의하여 객관적으로 구분된 사질토 및 점토와 전체 토사에 대한 변수별 경험적 상관식을 제안하였다. SCPTU의 다운홀 탄성파 시험과 일반적인 CPTU의 대상 변형률 수준이 다름에도 불구하고 본 연구에서 도출 제안된 VS와 CPTU 특성값의 상관관계는 국내 퇴적 지반에 대한 VS의 예측에 매우 유용하였으며, 기존 해외 연구의 상관관계에 비해서도 높은 상관성을 보였다.> (p value<0.000) 낮춤으로써, 전통적인 2문 대칭 조사법보다 우수한 방법으로 확인되었다. 반면에 공용보상체의 사용은 평균 DII를 $3.7\%$ 낮추지만(p value=0.260) 평균 $D_{max}$는 거의동일 하여($0.3\%$ 감소, p value=0.867), 전통적인 방법보다 우수성이 크게는 없는 것으로 평가되었다. 그러나 환자의 체곡선이 보상체와 잘 일치하는 경우에는 DII가 $18\%$까지 감소하였다. 결론 : Multistatic field 방법은 모든 환자에 대하여 선량분포의 균일성을 전반적으로 향상시키는 효과적인 방법으로 평가되는 반면 공용보상체의 사용은 보상체의 크기가 환자의 체 윤곽과 잘 일치하는 경우만 효과적으로, 적용의 범위에는 한계가 있는 방법으로 평가되었다.비교하여 계통에 따르는 차이가 있음을 알 수 있었다. 그러므로 가임기 여성의 방사선 진단 및 치료시 Rugh의 10일 법칙을 적용하여 착상전기 방사선 조사로 인한 부작용들을 적극적으로 예방하는 것이 매우 중요하다고 생각한다.equirements of the prematured infants during the early weeks of life. 모든 치근단 수준에서 비표준화 medium 크기 master cone 사용군이 ISO 표준화 규격의 master cone 사용군에 비해 유의하게 높은 gutta-percha 면적비를 나타내었다 (p < 0.01). 비표준화 medium크기 master cone 사용군에서는 표준화 규격의 master cone 사용군에 비해 유의하게 적은 수의 accessory cone이 사용되었다 (p < 0.01). 대학생간에는 유의한 차이(p<0.05)가 인정되었

  • PDF