• Title/Summary/Keyword: multiple reaction monitoring

Search Result 119, Processing Time 0.031 seconds

Rapid Quantitative Analysis of Vancomycin in Human Plasma and Urine Using LC-MS/MS (LC - MS/MS를 이용한 혈장과 뇨중에서 Vancomycin의 빠른정량분석)

  • Kim, Hohyun;Roh, Hyeongjin;Han, Sang-Beom
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.410-416
    • /
    • 2002
  • In this study, a new quantitative analytical method has been developed for the rapid determination of vancomycin in human plasma and urine using liquid chromatography/tandem mass spectrometry (LC - MS/MS). Chromatography was carried out on a $C_{18}$ XTerra MS column ($2.1{\times}30mm$) with a particle size of $3.5{\mu}m$. The mobile phase was 0.25% formic acid in 10% acetonitrile and the flow rate was $250{\mu}L/min$. Vancomycin and caffeine (internal standard) were detected by MS/MS using multiple reaction monitoring (MRM). Vancomycin gives a predominant doubly protonated precursor molecule ($[M+2H]^{2+}$) at m/z 725.0 and a corresponding product ion of m/z 100.0. Detection of vancomycin was good, accurate and precise, with a limit of detection of 1 nM in plasma. The calibration curves for vancomycin in human plasma was linear in a concentration range of $0.01{\mu}M$ - $100{\mu}M$ for plasma. This method has been successfully applied to determine the concentration of vancomycin in human plasma and urine from pharmacokinetic study and relative studies.

Simultaneous analysis of glucocorticoids in bovine muscle and liver by LC-MS/MS (LC-MS/MS를 이용한 소의 근육과 간 중에 잔류하는 glucocorticoids 동시 분석)

  • Shin, Sang-Eun;Cho, Hyun-Woo;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.23 no.4
    • /
    • pp.405-413
    • /
    • 2010
  • A new method for the simultaneous determination of six glucocorticoids (betamethasone, dexamethasone, prednisone, prednisolone, methylprednisolone, and flumethasone) in meats (bovine muscle, bovine liver) were established. Samples were effectively extracted using C18 cartridge with ethylacetate. Chromatographic separation was achieved using C18 column and negative electrospray ionization mass spectrometry was performed in the Multiple Reaction Monitoring mode for the effective quantitation and qualification of glucocorticoids. Acetonitrile and water (0.1% formic acid) were used as mobile phase and additive for effective electrospray ionization, and gave good chromatographic separation and mass spectrometric sensitivity. The limit of detection (LODs) and the limit of quantitation (LOQs) in spiked blank samples depending on types of matrix and pharmaceuticals were ranged from 0.2 to $1.0\;{\mu}g$/kg and 0.8 to $3.4\;{\mu}g$/kg, respectively. And the recoveries were between 89.5 to 119.6%. The established method showed good recoveries, accuracies, precisions and fast sample preparation and it will be applied to assay of glucocorticoids residues in meat.

Quantitative Analysis of Lysophosphatidic Acid in Human Plasma by Tandem Mass Spectrometry

  • Kim, Ho-Hyun;Yoon, Hye-Ran;Pyo, Dong-Jin
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.8
    • /
    • pp.1139-1143
    • /
    • 2002
  • Analysis of lysophosphatidic acids (LPAs) is of clinical importance as they can serve a potential marker for ovarian and other gynecological cancers and obesity. It is critically important to develop a highly sensitive and specific method for the early detection of gynecological cancers to improve the overall outcome of this disease. We have established a novel quantification method of LPAs in human plasma by negative ionization tandem mass spectrometry (MS-MS) using multiple reaction monitoring (MRM) mode without the conventional TLC step. Protein-bound lipids, LPAs in plasma were extracted with methanol : chloroform (2:1) containing LPA C14:0 as an internal standard under acidic condition. Following back extraction with chloroform and water, the centrifuged lower phase was evaporated and reconstituted in methanol. The reconstituted solution was directly injected into electrospray source of MS/MS. For MRM mode, Q1 ions selected were m/z 409, 433, 435, 437 and 457 which corresponds to molecular mass [M-H]- of C16:0, C18:2, C18:1, C18:0 and C20:4 LPA, respectively. Q2 ions selected for MRM were m/z 79, phosphoryl product. Using MS/MS with MRM mode, all the species of LPAs were completely separated from plasma matrix without severe interferences. This method allowed simultaneous detection and quantification of different species of LPAs in a plasma over a linear dynamic range of 0.01-25 ㎛olL-1 . The detection limit of the method was 0.3 pmol/mL, with a correlation coefficient of 0.9983 in most LPAs analyzed. When applied to the plasmas of normal and gynecological cancer patients, this new method differentiated two different groups by way of total LPA level.

A Simple and Efficient Method to Determine Montelukast in Rat Plasma Using Liquid-Liquid Extraction and Tandem Mass Spectrometry

  • Kim, Dong Yoon;Lee, Hyo Chun;Jang, Yong Jin;Kim, Jin Hee;Lee, Ha Ryeong;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.71-76
    • /
    • 2020
  • While montelukast (ML), a cysteinyl-leukotriene type 1 receptor (CysLT1) antagonist is widely used to treat symptoms of rhinitis or asthma, its formulations are mainly limited to solid preparation due to its instability. Recently, there have been attempts to develop various ML dosage forms, and this situation increases the demand of sensitive and creditable methods to determine ML in various samples such as plasma. Thus, here, a simple and efficient method to determine ML in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was presented. The mixture of DCM:EtOAc (25:75, v/v), the optimized extract solvent for LLE was found to be effective to extract ML without hydrophilic salts and proteins from the sample with limited volume. Also, the use of zafirlukast, instead of expensive ML-d6, as the internal standard makes the present method economical. The developed method was successfully validated in terms of selectivity, matrix effects (-14.8--6.9%), linearity (r230.998 within 0.5-500 ng/mL), sensitivity (the limit of detection and the lower limit of quantitation, ≤0.5 ng/mL), accuracy (88.4-100.6%), precision (3.0-13.3%), and recovery (80.8-86.3%) by following the FDA guidelines. Finally, the applicability of the validated method to pharmacokinetics (PK) studies was confirmed by the successful determination of PK parameters through it following oral administration of Singulair® granule in rats. Therefore, the present method can contribute to the development of new ML formulations through its performance to determine ML in rat plasma efficiently and sensitively.

Development of Analytic Methods for Veterinary Drug Residue in Animal Products by Liquid Chromatography-Mass Spectrometry (축산물 중 잔류 성장보조제 분석을 위한 액체크로마토그라피-질량분석법 개발 및 적용)

  • Lee, Soo Hyun
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.2
    • /
    • pp.107-116
    • /
    • 2021
  • In this study, an analytical method was developed for estradiol-17��, testosterone, and progesterone, which are growth promoters as veterinary drug residues in animal food. The analytes were separated using liquid chromatography, and was injected into a mass spectrometer through the electrospray ionization(ESI) process and detected in multiple reaction monitoring(MRM) mode. As the method was validated by CODEX CAC/GL 71-2009 guideline, it met the acceptable. The analysis of beef, pork, and chicken distributed in Korea was conducted with an established method to confirm the applicability of the actual sample. It was confirmed that the developed method can be quickly and reliably in the analysis for the growth promoters identified in domestic distributed livestock products. Through subsequent research, a highly utilized analysis method will be completed if the number of growth promoters is expanded based on the method and the simultaneous analytical method is established by including all of it.

A Sensitive, Efficient, and Cost-Effective Method to Determine Rotigotine in Rat Plasma Using Liquid-Liquid Extraction (LLE) and LC-MRM

  • Kim, Ji Seong;Jang, Yong Jin;Kim, Jin Hee;Kim, Jin Hwan;Seo, Jae Hee;Park, Il-Ho;Kang, Myung Joo;Choi, Yong Seok
    • Mass Spectrometry Letters
    • /
    • v.13 no.4
    • /
    • pp.146-151
    • /
    • 2022
  • Rotigotine (RTG) is a non-ergot dopamine agonist used to manage the early stage of Parkinson's disease (PD) as transdermal patch. However, the poor medication compliance of PD patients and skin issues related with repeated applications of RTG patches lead to the search for alternative formulations and it also requires appropriate analytical methods for their in vivo evaluation. Thus, here, a sensitive, efficient, and cost-effective method to determine RTG in rat plasma using liquid-liquid extraction (LLE) and multiple reaction monitoring was developed. The use of 20 µL of rat plasma for sample treatment, 8-OH-DPAT as the internal standard, and methyl tert-butyl ether as the LLE solvent in the present method gives it advantages over previous methods for the analysis of RTG in biological samples. The good analytical performance of the developed method was confirmed in specificity, linearity (the coefficient of determination ≥0.999 within 0.1-100 ng/mL), sensitivity (the lower limit of quantitation at 0.1 ng/mL), accuracy (81.00-115.05%), precision (≤10.75%), and recovery (81.00-104.48%) by following the FDA guidelines. Finally, the applicability test of the validated method to the in vivo evaluation of a RTG formulation showed that the present method is the only method which can be accurately applied to that longer than 24 hours, critical for the development of formulations with reduced dosing frequencies. Therefore, the present method could contribute to the development of new RTG formulations helpful to people suffering from PD.

Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration (성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립)

  • Jeong, Sujin;Baeck, Seungkyung;Park, Sunhye;Son, Kkonnip;Park, Yonghoon;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Determination of more than 500 Pesticide Residues in Hen Eggs by Liquid Chromatography-Tandem Mass Spectrometry (LC-MS/MS) and Gas Chromatography-Tandem Mass Spectrometry (GC/MS/MS)

  • Golge, Ozgur;Liman, Turan;Kabak, Bulent
    • Food Science of Animal Resources
    • /
    • v.41 no.5
    • /
    • pp.816-825
    • /
    • 2021
  • This study aims to validate a fast method of simultaneous analysis of 365 LCamenable and 142 GC-amenable pesticides in hen eggs by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and gas chromatography-tandem mass spectrometry (GC-MS/MS), respectively, operating in multiple reaction monitoring (MRM) acquisition modes. The sample preparation was based on quick, easy, cheap, effective, rugged, and safe (QuEChERS) extraction. Key method performance parameters investigated were specificity, linearity, limit of quantification (LOQ), accuracy, precision and measurement uncertainty. The method was validated at two spiking levels (10 and 50 ㎍/kg), and good recoveries (70%-120%) and relative standard deviations (RSDs) (≤20) were achieved for 92.9% of LC-amenable and 86.6% of GC-amenable pesticide residues. The LOQs were ≤10 ㎍/kg for 94.2% of LC-amenable and 92.3% of GC-amenable pesticides. The validated method was further applied to 100 egg samples from caged hens, and none of the pesticides was quantified.

Review of Analytical and Assessment Techniques of Terminal Electron Accepting Processes (TEAPs) for Site Characterization and Natural Attenuation in Contaminated Subsurface Environments (오염 지중환경 특성화와 자연저감평가를 위한 말단전자수용과정(TEAPs) 분석 및 평가기술 소개)

  • Song, Yun Sun;Kim, Han-Suk;Kwon, Man Jae
    • Journal of Soil and Groundwater Environment
    • /
    • v.25 no.2_spc
    • /
    • pp.1-15
    • /
    • 2020
  • Monitoring and assessing terminal electron accepting processes (TEAPs) are one of the most important steps to remediate contaminated sites via various in-situ techniques. TEAPs are a part of the microbial respiration reactions. Microorganisms gain energy from these reactions and reduces pollutants. Monitoring TEAPs enables us to predict degradability of contaminants and degradation rates. In many countries, TEAPs have been used for characterization of field sites and management of groundwater wells. For instance, US Environmental Protection Agency (EPA) provided strategies for groundwater quality and well management by applying TEAPs monitoring. Denmark has also constructed TEAPs map of local unit area to develop effective groundwater managing system, particularly to predict and assess nitrogen contamination. In case of Korea, although detailed soil survey and groundwater contamination assessment have been employed, site investigation guidelines using TEAPs have not been established yet. To better define TEAPs in subsurface environments, multiple indicators including ion concentrations, isotope compositions and contaminant degradation byproducts must be assessed. Furthermore, dissolved hydrogen concentrations are regarded as significant evidence of TEAPs occurring in subsurface environment. This review study introduces optimal sampling techniques of groundwater and dissolved hydrogen, and further discuss how to assess TEAPs in contaminated subsurface environments according to several contamination scenarios.

Dynamic MRM Measurements of Multi-Biomarker Proteins by Triple-Quadrupole Mass Spectrometry with Nanoflow HPLC-Microfluidics Chip

  • Ji, Eun-Sun;Cheon, Mi-Hee;Lee, Ju-Yeon;Yoo, Jong-Shin;Jung, Hyun-Jin;Kim, Jin-Young
    • Mass Spectrometry Letters
    • /
    • v.1 no.1
    • /
    • pp.21-24
    • /
    • 2010
  • The development of clinical biomarkers involves discovery, verification, and validation. Recently, multiple reaction monitoring (MRM) coupled with stable isotope dilution mass spectrometry (IDMS) has shown considerable promise for the direct quantification of proteins in clinical samples. In particular, multiple biomarkers have been tracked in a single experiment using MRM-based MS approaches combined with liquid chromatography. We report here a highly reproducible, quantitative, and dynamic MRM system for validating multi-biomarker proteins using Nanoflow HPLC-Microfluidics Chip/Triple-Quadrupole MS. In this system, transitions were acquired only during the retention window of each eluting peptide. Transitions with the highest MRM-MS intensities for the five target peptides from colon cancer biomarker candidates were automatically selected using Optimizer software. Relative to the corresponding non-dynamic system, the dynamic MRM provided significantly improved coefficients of variation in experiments with large numbers of transitions. Linear responses were obtained with concentrations ranging from fmol to pmol for five target peptides.