• Title/Summary/Keyword: multiple parallel operation

Search Result 88, Processing Time 0.024 seconds

Adaptive Resource Allocation for MC-CDMA and OFDMA in Reconfigurable Radio Systems

  • Choi, Yonghoon
    • ETRI Journal
    • /
    • v.36 no.6
    • /
    • pp.953-959
    • /
    • 2014
  • This paper studies the uplink resource allocation for multiple radio access (MRA) in reconfigurable radio systems, where multiple-input and multiple-output (MIMO) multicarrier-code division multiple access (MC-CDMA) and MIMO orthogonal frequency-division multiple access (OFDMA) networks coexist. By assuming multi-radio user equipment with network-guided operation, the optimal resource allocation for MRA is analyzed as a cross-layer optimization framework with and without fairness consideration to maximize the uplink sum-rate capacity. Numerical results reveal that parallel MRA, which uses MC-CDMA and OFDMA networks concurrently, outperforms the performance of each MC-CDMA and OFDMA network by exploiting the multiuser selection diversity.

Investigation of I-V characteristics and heat generation of multiply connected HTS conductors in parallel

  • Park, H.C.;Kim, S.;Cho, J.;Sohn, M.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.14 no.2
    • /
    • pp.20-23
    • /
    • 2012
  • With continuous development of the 2nd generation HTS conductor, the critical current of the conductor is also increasing. However, many applications require more than 2 conductors in parallel to transport large current. Applications such as HTS power cables and some HTS current leads usually need much larger transport current than that provided by a single conductor and they require more than several tens of HTS conductors. In the case of parallel connection of multiple HTS conductors, the current distribution depends on the contact resistance of each conductor at the terminals for DC operation. The non-uniform distribution of the terminal resistances results in a non-uniform distribution of the current. The resultant current non-uniformity affects on the measurement of the I-V curve and the thermal performance of the multiple conductors. This paper describes the I-V curves obtained from multiply connected HTS conductors with different terminal contact resistances to investigate the relationship between the distorted I-V curve and heat generation.

New Mathematical Model and Parallel Hybrid Genetic Algorithm for the Optimal Assignment of Strike packages to Targets (공격편대군-표적 최적 할당을 위한 수리모형 및 병렬 하이브리드 유전자 알고리즘)

  • Kim, Heungseob;Cho, Yongnam
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.566-578
    • /
    • 2017
  • For optimizing the operation plan when strike packages attack multiple targets, this article suggests a new mathematical model and a parallel hybrid genetic algorithm (PHGA) as a solution methodology. In the model, a package can assault multiple targets on a sortie and permitted the use of mixed munitions for a target. Furthermore, because the survival probability of a package depends on a flight route, it is formulated as a mixed integer programming which is synthesized the models for vehicle routing and weapon-target assignment. The hybrid strategy of the solution method (PHGA) is also implemented by the separation of functions of a GA and an exact solution method using ILOG CPLEX. The GA searches the flight routes of packages, and CPLEX assigns the munitions of a package to the targets on its way. The parallelism enhances the likelihood seeking the optimal solution via the collaboration among the HGAs.

Parallel Algorithm of Improved FunkSVD Based on Spark

  • Yue, Xiaochen;Liu, Qicheng
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.15 no.5
    • /
    • pp.1649-1665
    • /
    • 2021
  • In view of the low accuracy of the traditional FunkSVD algorithm, and in order to improve the computational efficiency of the algorithm, this paper proposes a parallel algorithm of improved FunkSVD based on Spark (SP-FD). Using RMSProp algorithm to improve the traditional FunkSVD algorithm. The improved FunkSVD algorithm can not only solve the problem of decreased accuracy caused by iterative oscillations but also alleviate the impact of data sparseness on the accuracy of the algorithm, thereby achieving the effect of improving the accuracy of the algorithm. And using the Spark big data computing framework to realize the parallelization of the improved algorithm, to use RDD for iterative calculation, and to store calculation data in the iterative process in distributed memory to speed up the iteration. The Cartesian product operation in the improved FunkSVD algorithm is divided into blocks to realize parallel calculation, thereby improving the calculation speed of the algorithm. Experiments on three standard data sets in terms of accuracy, execution time, and speedup show that the SP-FD algorithm not only improves the recommendation accuracy, shortens the calculation interval compared to the traditional FunkSVD and several other algorithms but also shows good parallel performance in a cluster environment with multiple nodes. The analysis of experimental results shows that the SP-FD algorithm improves the accuracy and parallel computing capability of the algorithm, which is better than the traditional FunkSVD algorithm.

Implementation of MPI-based WiMAX Base Station for SDR System (SDR 시스템을 위한 MPI 기반 WiMAX 기지국의 구현)

  • Ahn, Chi Young;Kim, Hyo Han;Choi, Seung Won
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.4
    • /
    • pp.59-67
    • /
    • 2013
  • Compared to the conventional Hardware-oriented base stations, Software Defined Radio (SDR)-based base station provides various advantages especially in flexibility and expandability. It enables the multimode capability required in 4th-generation (4G) environment which aims at a convergence network of various kinds of communication standards. However, since a single base station processes all data required in various multiple waveforms, the SDR base station faces a problem of data processing speed. In this paper, we propose a new concept of SDR base station system which adopts a parallel processing technology of clustering environment. We implemented a WiMAX system with SDR concept which adopts the Message Passing Interface (MPI) technology which enables the speed-up operations. In order to maximize the efficiency of parallel processing in signal processing, we analyze how the algorithm at each of modules is related to data to be processed. Through the implemented system, we show a drastic improvement in operation time due to parallel processing using the proposed MPI technology. In addition, we demonstrate a feasibility of SDR system for 4G or even beyond-4G as well.

A Study on N-Channel Data Correlators for Multirate in IMT-2000 (IMT-2000에서 Multirate를 위한 N-채널 데이터 상관기에 관한 연구)

  • 김종엽;이선근;김환용
    • Proceedings of the IEEK Conference
    • /
    • 2000.06a
    • /
    • pp.49-52
    • /
    • 2000
  • The Multi-Code CDMA systems that are proposed as an effective transmission methodology in the IMT-2000 systems allow higher rate services under the IS-95 CDMA infrastructure. The Multi-Code CDMA systems convert the higher rate data into the lower rate by serial to parallel operation and spread the converted data streams by the multiple walsh codes, and its mobile receiver needs multiple walsh generators and data correlators to demodulate simultaneously multiple walsh code channels. Therefore, the number of data correlators is increased as the number of traffic channels increases. In this paper, we proposed the new structure of the data correlators using walsh overlay coding, the shared accumulator, and FWHT(Fast Walsh Hadamard Transform) algorithm for reducing the bottle-neck effect resulting the increase of the number of data correlators.

  • PDF

Development of Battery Management System using Multiple Microcontroller (다중 마이크로콘트롤러를 사용한 배터리 관리 시스템의 개발)

  • Choi, Jeong-Won;Jang, WoonGeun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.6
    • /
    • pp.329-335
    • /
    • 2018
  • In an electric vehicle and Energy Storage System(ESS), a large number of batteries are connected in series or parallel to obtain high voltage and current. The battery management system(BMS) is needed because battery has a characteristic that explode in overcharging and overcurrent situations due to the nature of the battery material and the battery life is dramatically reduced when the battery is overdischarged below the specified voltage. In this paper, we proposed a system that can manage a large amount of batteries through the communication of master-slave type with multiple microcontroller. We confirmed the stable operation of the proposed system through the balancing-charging and storage mode experiments.

Stability Enhancement of a Hybrid Micro-grid System in Grid Fault Condition

  • Ambia, Mir Nahidul;Al-Durra, Ahmed;Caruana, Cedric;Muyeen, S.M.
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.2
    • /
    • pp.225-231
    • /
    • 2013
  • Low voltage ride through capability augmentation of a hybrid micro-grid system is presented in this paper which reflects enhanced reliability in the system. The control scheme involves parallel connected multiple ac-dc bidirectional converters. When the micro-grid system is subjected to a severe voltage dip by any transient fault single power converter may not be able to provide necessary reactive power to overcome the severe voltage dip. This paper discusses the control strategy of additional power converter connected in parallel with main converter to support extra reactive power to withstand the severe voltage dip. During transient fault, when the terminal voltage crosses 90% of its pre-fault value, additional converter comes into operation. With the help of additional power converter, the micro-grid system withstands the severe voltage fulfilling the grid code requirements. This multiple converter scheme provides the micro-grid system the capability of low voltage ride through which makes the system more reliable and stable.

Z-score Based Abnormal Detection for Stable Operation of the Series/Parallel-cell Configured Battery Pack (직병렬조합 배터리팩의 안전운용을 위한 Z-score 기반 이상 동작 검출 방법)

  • Kang, Deokhun;Lee, Pyeong-Yeon;Kim, Deokhan;Kim, Seung-Keun;Kim, Jonghoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.390-396
    • /
    • 2021
  • Lithium-ion batteries have been designed and used as battery packs with series and parallel combinations that are suitable for use. However, due to its internal electrochemical properties, producing the battery's condition at the same value is impossible for individual cells. In addition, the management of characteristic deviations between individual cells is essential for the safe and efficient use of batteries as aging progresses with the use of batteries. In this work, we propose a method to manage deviation properties and detect abnormal behavior in the configuration of a combined battery pack of these multiple battery cells. The proposed method can separate and detect probabilistic low-frequency information according to statistical information based on Z-score. The verification of the proposed algorithm was validated using experimental results from 10S3P battery packs, and the implemented algorithm based on Z-score was validated as a way to effectively manage multiple individual cell information.

A Study on the Four AC/DC Converter Parallel Operation for a Traction Drive (견인용 AC/DC 컨버터 4병렬 운전에 관한 연구)

  • Ryoo, Hong-Je;Woo, Myung-Ho;Kim, Jong-Soo;Kim, Won-Ho;Rim, Geun-Hie
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2671-2673
    • /
    • 1999
  • Front end AC to DC converters of the boost type are used in traction applications for generating the DC link for the inverters. A GTO based converter is usually switched with a switching frequency of 300 to 500Hz, resulting in low frequency harmonic problems. In order to avoid this, multiple converters with phase shifted carrier signals are used to suppress the low frequency harmonics. A detailed study of an AC to DC converter, parallel operated with reduced sensor and improved power-factor in light load conditions is presented in this paper.

  • PDF