• 제목/요약/키워드: multiple parallel operation

검색결과 88건 처리시간 0.03초

용량성 결합을 고려한 CCFL 병렬 구동 (Parallel Operation of CCFLs Considering on Capacitive Coupling)

  • 박정오;김철진;박현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1007-1009
    • /
    • 2008
  • This paper presents an architecture for driving multiple paralleled cold cathode fluorescent lamps (CCFLs) for back lighting applications. The key to the architecture is a proposed capacitive coupling approach for lamp ignition. This system is consist of a flyback converter, a single inverter to drive multiple lamps and conductive floating reflector. The topology is capable of driving a number of parallel lamps with independent accurate lamp, current regulation and improving cost effectiveness with significant reduction in size and weight, compared to typical high frequency ac ballast. Experimental demonstration results for ten of parallel CCFLs with simultaneous ignition. This like the EEFL it will be able to use the CCFL is the thing. Also, it investigates the effect where the leakage current goes mad to the Lamp.

  • PDF

단위역률 정류기의 병렬운전 (Parallel operation of rectifier with unit-power factor)

  • 이성희;김태원;박재욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.1212-1213
    • /
    • 2011
  • PWM(pulse width modulation) rectifier has unit power factor and low harmonic distortion with high power conversion efficiency in entire loading range. These merits of PWM rectifier help the spread of DC distribution system. In addition, if multiple PWM rectifiers can be operated in parallel connection, maintenance process can be simple and reliability of power source can be advanced because of the hot swapping is available. The other way, the load unbalance among rectifiers can force a converter to stop by over current. The surge current by closed circuit composition between rectifiers can force switching devices damage. In this paper, some problems that can occur in case of parallel operation of PWM rectifiers and problem eliminating methods are considered.

  • PDF

사병렬 초전도코일의 전류분류 측정을 위한 Rogowski 코일의 제작 및 특성 실험 (Design and test results of a Rogowski coil for measurement of current distribution characteristics in 4-parallel superconducting coils)

  • 조대호;양성은;김민재;안민철;박동근;배덕권;석복렬;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제9권3호
    • /
    • pp.37-40
    • /
    • 2007
  • Large critical current is one of the prerequisites for the design of superconducting electrical equipments with large power capacity. To enlarge the critical current. multiple parallel connection is inevitable. In multiple parallel superconducting coils. the difference in normal resistance of each shunt leads to unequal current distribution. which may yield burnout. Therefore. uniform current distribution is required for a stable operation of multiple parallel superconducting coils. In this paper, Rogowski coils were fabricated to measure each shunt current of a 4-parallel superconducting coil. Four Rogowski coils were installed at the copper bars, which are used as current leads in superconducting coils. As a result, linearity of the Rogowski coils was ascertained and coefficients of each coil, the ratio of voltage and current, were derived. The coefficients were compared with theoretically calculated values. Based on the coefficients, each shunt current was calculated in a 4-parallel superconducting coil, where uniform current. distribution was confirmed. This paper verified the feasibility of the fabricated Rogowski coils as well as operational stability of the 4-parallel superconducting coil in 77K.

Parallel Control of Shunt Active Power Filters in Capacity Proportion Frequency Allocation Mode

  • Zhang, Shuquan;Dai, Ke;Xie, Bin;Kang, Yong
    • Journal of Power Electronics
    • /
    • 제10권4호
    • /
    • pp.419-427
    • /
    • 2010
  • A parallel control strategy in capacity proportion frequency allocation mode for shunt active power filters (APFs) is proposed to overcome some of the difficulties in high power applications. To improve the compensation accuracy and overall system stability, an improved selective harmonic current control based on multiple synchronous rotating reference coordinates is presented in a single APF unit, which approximately implements zero steady-state error compensation. The combined decoupling strategy is proposed and theoretically analyzed to simplify selective harmonic current control. Improved selective harmonic current control forms the basis for multi-APF parallel operation. Therefore, a parallel control strategy is proposed to realize a proper optimization so that the APFs with a larger capacity compensate more harmonic current and the ones with a smaller capacity compensate less harmonic current, which is very practical for accurate harmonic current compensation and stable grid operation in high power applications. This is verified by experimental results. The total harmonic distortion (THD) is reduced from 29% to 2.7% for a typical uncontrolled rectifier load with a resistor and an inductor in a laboratory platform.

SDR 시스템에서 GPU를 사용한 Lattice Reduction-aided 검출기 구현 (Implementation of Lattice Reduction-aided Detector using GPU on SDR System)

  • 김태현;이현석;최승원
    • 디지털산업정보학회논문지
    • /
    • 제7권3호
    • /
    • pp.55-61
    • /
    • 2011
  • This paper presents an implementation of Lattice Reduction (LR)-aided detector for Multiple-Input Multiple-Output (MIMO) system using Graphics Processing Unit (GPU). GPU is a parallel processor which has a number of Arithmetic Logic Units (ALUs), thus, it can minimize the operation time of LR algorithm through the parallelization using multiple threads in the GPU. Through the implemented LR-aided detector, we verify that the LR-aided detector operates a lot faster than Maximum Likelihood (ML) detector. The implemented LR-aided detector has been applied to WiMAX system to show the feasibility of its real-time processing. In addition, we demonstrate that the processing time can be reduced at the cost of 3dB SNR loss by limiting the repeating loop in Lenstra-Lenstra-Lovasz (LLL) algorithm which is frequently used in LR-aided detector.

Static UPS 병렬운전 제어 (The Control of Parallel Operation for Static UPSs)

  • 김동욱;김연풍;신현주;백병산;류승표;민병권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2048-2050
    • /
    • 1998
  • An uninterruptible power supply(UPS) with parallel operation is used to increase the power capacity of the system or to secure higher reliability at critical loads. In the parallel operating system composed of the multiple UPSs, load-sharing, i.e. current balance control between them is key technique. Because of its low impedance and quick response characteristics, inverter output current changes very rapidly and thereby easily researches an overload condition. The difference between total load current divided by number of operating inverters and its own current is detected as unbalanced current. Then frequency and voltage are controlled to minimize the active component and the reactive component. A good performance of the proposed load-sharing technique is verified by experiments in the parallel operating system with two 40kVA UPSs.

  • PDF

병렬운전하는 계통연계형 태양광 발전용 인버터의 단독운전 검출 성능 분석 (Performance Analysis of Anti-islanding Function for Grid-connected PV Inverter Systems under Parallel Connections)

  • 정영석;유병규;강기환
    • 한국태양에너지학회 논문집
    • /
    • 제33권5호
    • /
    • pp.34-40
    • /
    • 2013
  • Islanding phenomenon of photovoltaic system is undesirable because it leads to a safety hazard to utility service personnel and may cause damage to power generation and power supply facilities as a result of unsynchronized re-closure. Anti-islanding protection is an important technical requirement for grid-connected PV system. Until now, various anti-islanding methods for detecting and preventing islanding of photovoltaic and other distributed generations have been proposed. Most of them are focusing on the anti-islanding performance of single PV system according to the related international and domestic standard test procedures. There are few studies on the islanding phenomenon for multiple photovoltaic operation in parallel. This paper presents performance analysis of anti-islanding function for grid-connected PV inverter systems when several PV inverters are connected in parallel.

다중 GPU기반 홀로그램 생성을 위한 병렬처리 성능 최적화 기법 (An Optimization Method for Hologram Generation on Multiple GPU-based Parallel Processing)

  • 국중진
    • 스마트미디어저널
    • /
    • 제8권2호
    • /
    • pp.9-15
    • /
    • 2019
  • 홀로그램의 생성을 위한 연산은 포인트 클라우드의 규모에 따라 연산량이 기하급수적으로 증가하기 때문에 최근에는 다중의 GPU를 기반으로 CUDA 또는 OpenCL 라이브러리를 활용한 병렬처리가 이루어지고 있다. GPU기반의 병렬처리를 위한 CUDA 커널은 GPU의 코어 개수와 메모리 크기를 고려하여 쓰레드(thread), 블록(block), 그리드(grid)를 구성해야 하며, 다중 GPU 환경인 경우 GPU의 개수에 따른 그리드, 블록, 또는 쓰레드 단위의 분산처리가 필요하다. 본 논문에서는 CGH 생성에 대한 성능평가를 위해 포인트 클라우드의 포인트 개수를 10~1,000,000개 범위에서 점진적으로 증가시키면서 CPU, 단일 GPU, 다중 GPU 환경에서 연산 속도를 비교해 보았으며, 다중 GPU 환경에서 CGH(Computer Generated Hologram) 생성 연산을 가속화하기 위한 CUDA 기반의 병렬처리 과정에서 요구되는 메모리 구조 설계와 연산 방법을 제안한다.

A Novel Reconfigurable Processor Using Dynamically Partitioned SIMD for Multimedia Applications

  • Lyuh, Chun-Gi;Suk, Jung-Hee;Chun, Ik-Jae;Roh, Tae-Moon
    • ETRI Journal
    • /
    • 제31권6호
    • /
    • pp.709-716
    • /
    • 2009
  • In this paper, we propose a novel reconfigurable processor using dynamically partitioned single-instruction multiple-data (DP-SIMD) which is able to process multimedia data. The SIMD processor and parallel SIMD (P-SIMD) processor, which is composed of a number of SIMD processors, are usually used these days. But these processors are inefficient because all processing units (PUs) should process the same operations all the time. Moreover, the PUs can process different operations only when every SIMD group operation is predefined. We propose a processor control method which can partition parallel processors into multiple SIMD-based processors dynamically to enhance efficiency. For performance evaluation of the proposed method, we carried out the inverse transform, inverse quantization, and motion compensation operations of H.264 using processors based on SIMD, P-SIMD, and DP-SIMD. Experimental results show that the DP-SIMD control method is more efficient than SIMD and P-SIMD control methods by about 15% and 14%, respectively.

An Excessive Current Subtraction Technique to Improve Dynamic Range for Touch Screen Panel Applications

  • Heo, Sanghyun;Ma, Hyunggun;Bien, Franklin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제16권3호
    • /
    • pp.375-379
    • /
    • 2016
  • A current subtraction technique with parallel operation system is proposed to remove excessive current in touch screen application. The proposed current subtraction remove the current which go into the input node of charge amplifier. The value of subtraction current is same with current when touch screen is not touched. As a result, charge amplifier output is only proportional to variation of mutual capacitor, which make dynamic rage is increased. Also, Transmitter (Tx) driving signal and subtraction driving signal are out of phase each other. Thus, noise generated in Tx is cancelled. The proposed IC is implemented in a mixed-mode 0.18-um CMOS process. Overall system is designed for touch screen panel (TSP) with 16 driving lines and 8 sensing lines. 5-V supply voltages are used in the proposed circuits. For multiple Tx driving signal, Walsh codes are used and signal frequency is 300 khz. By using proposed technique, dynamic rage is improved 36 dB.