• 제목/요약/키워드: multiple parallel operation

검색결과 88건 처리시간 0.022초

정지형 UPS의 병렬운전 제어 (The Parallel Operation Control of Static UPSs)

  • 민병권;원충윤
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권7호
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

UPS시스템의 병렬운전 제어기법 (The Parallel Operation Control Technique of UPS System)

  • 이상훈;이우철;김경환;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.158-162
    • /
    • 2002
  • The parallel operation system of multiple UPS(Uninterruptible Power Supply) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load sharing control to maintain the current balance between them is a matter of consequence. In this paper, a highly precise load sharing controller is proposed and implemented for the parallel operation system of two UPSs. After that, a good performance of the proposed method is verified by simulation in the parallel operation system with two UPSs.

  • PDF

LonWorks 시스템을 이용한 소형빙축열 에어컨의 병렬 제어 (Parallel Control of Mini Ice Storage Air Conditioner Using LonWorks System)

  • 김홍열;조성규;정남종;김대원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 D
    • /
    • pp.2358-2361
    • /
    • 2003
  • In this paper, parallel control method that enables coordinating operations of multiple mini ice storage air conditioner is proposed based on LonWorks system. The proposed parallel control method is a kind of master/slave control method based on LonTalk network communication. In the control method, master controller leading whole system operations is determined by date to avoid the disproportion of outdoor unit operations. In addition to the above, duty shift control method is proposed to avoid redundant operations of outdoor units and to equalize the operation frequencies of them. Through some simulation tests, the proposed parallel control method and the duty shift control method are evaluated and the efficiencies of them are validated by comparing with existing methods.

  • PDF

다수의 CCFL 구동과 휘도 향상에 관한 연구 (A Study on the Multiple CCFL Operation and Brightness Improvement)

  • 박정오;김철진;박현철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.126-128
    • /
    • 2008
  • This paper presents an architecture for driving multiple paralleled cold cathode fluorescent lamps (CCFLs) for back lighting applications. Multi CCFL operation and increase of brightness, the key to the architecture is a proposed capacitive coupling approach for lamp ignition. This system is consist of a flyback converter, a single inverter to drive multiple lamps and conductive floating reflector. The topology is capable of driving a number of parallel lamps with independent accurate lamp, The capacitive coupling the leakage inductance and stray capacitance creation which it used, current regulation and improving cost effectiveness with significant reduction in size and weight, compared to typical high frequency ac ballast. Experimental demonstration results for ten of parallel CCFLs with simultaneous ignition.

  • PDF

그래프이론에 의한 데이터베이스 세그먼트 분산 알고리즘 (Database Segment Distributing Algorithm using Graph Theory)

  • 김중수
    • 한국멀티미디어학회논문지
    • /
    • 제22권2호
    • /
    • pp.225-230
    • /
    • 2019
  • There are several methods which efficiencies of database are uprise. One of the well-known methods is that segments of database satisfying a query was rapidly accessed and processed. So if it is possible to search completely parallel multiple database segment types which satisfy a query, the response time of the query will be reduced. The matter of obtaining CPS(Completely Parallel Searchable) distribution without redundancy can be viewed as graph theoretic problem, and the operation of ring sum on the graph is used for CPS. In this paper, the parallel algorithm is proposed.

독립제어구조를 갖는 N+1 모듈형 UPS 시스템의 병렬운전 (Wireless Parallel Operation Control of N+1 Redundant UPS System)

  • 조준석;한재원;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 전력전자학술대회 논문집
    • /
    • pp.734-738
    • /
    • 2002
  • In this paper, a novel wireless parallel operation algorithm of N+1 redundant UPS system with no control interconnections is presented. The load sharing of multiple UPS modules are controlled by Q-V droop and $P-\delta$ droop algorithm. This algorithm compensates for inverter parameter variation and line impedance imbalances with wireless auto-tuning method. And to increase the reliability of transient characteristic under parallel operation, a virtual injected Impedance is proposed to decrease a circulation current between inverter modules. Simulation results are provided to prove the novel wireless algorithm.

  • PDF

A Parallel Collaborative Sphere Decoder for a MIMO Communication System

  • Koo, Jihun;Kim, Soo-Yong;Kim, Jaeseok
    • Journal of Communications and Networks
    • /
    • 제16권6호
    • /
    • pp.620-626
    • /
    • 2014
  • In this paper, we propose a parallel collaborative sphere decoder with a scalable architecture promising quasi-maximum likelyhood performance with a relatively small amount of computational resources. This design offers a hardware-friendly algorithm using a modified node operation through fixing the variable complexity of the critical path caused by the sequential nature of the conventional sphere decoder (SD). It also reduces the computational complexity compared to the fixed-complexity sphere decoder (FSD) algorithm by tree pruning using collaboratively operated node operators. A Monte Carlo simulation shows that our proposed design can be implemented using only half the parallel operators compared to the approach using an ideal fully parallel scheme such as FSD, with only about a 7% increase of the normalized decoding time for MIMO dimensions of $16{\times}16$ with 16-QAM modulation.

Variation-tolerant Non-volatile Ternary Content Addressable Memory with Magnetic Tunnel Junction

  • Cho, Dooho;Kim, Kyungmin;Yoo, Changsik
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제17권3호
    • /
    • pp.458-464
    • /
    • 2017
  • A magnetic tunnel junction (MTJ) based ternary content addressable memory (TCAM) is proposed which provides non-volatility. A unit cell of the TCAM has two MTJ's and 4.875 transistors, which allows the realization of TCAM in a small area. The equivalent resistance of parallel connected multiple unit cells is compared with the equivalent resistance of parallel connected multiple reference resistance, which provides the averaging effect of the variations of device characteristics. This averaging effect renders the proposed TCAM to be variation-tolerant. Using 65-nm CMOS model parameters, the operation of the proposed TCAM has been evaluated including the Monte-Carlo simulated variations of the device characteristics, the supply voltage variation, and the temperature variation. With the tunneling magnetoresistance ratio (TMR) of 1.5 and all the variations being included, the error probability of the search operation is found to be smaller than 0.033-%.

GPU를 사용한 효율적인 공간 데이터 처리 (An Efficient Technique for Processing of Spatial Data Using GPU)

  • 이재일;오병우
    • Spatial Information Research
    • /
    • 제17권3호
    • /
    • pp.371-379
    • /
    • 2009
  • 최근 그래픽 프로세서(GPU)의 발전에 따라 대량의 프로세서를 탑재한 고성능 그래픽 카드가 개인 컴퓨터에서 널리 사용되고 있다. GPU를 사용하여 CPU의 부하를 줄이면서도 성능을 향상시킬 수 있어서 복잡한 연산을 처리해야 하는 다양한 응용 프로그램에 적용하는 연구가 활발히 진행되고 있다. 본 논문에서는 복잡한 연산이 필요한 공간 데이터 처리의 성능을 향상시키기 위하여 GPU의 병렬 처리 기술을 활용하는 방법을 제안하였다. 원본 공간 데이터를 화면에 출력하기 위해서는 그래픽 처리 연산이 필요하며 같은 종류의 연산을 모든 데이터에 적용해야 하므로 GPU의 SIMD 병렬 처리를 사용하여 성능을 향상시킬 수 있다.

  • PDF