• 제목/요약/키워드: multiple heat sources

검색결과 28건 처리시간 0.021초

다차원 스펙트럼 해석법을 이용한 PDP TV의 저소음화 (Noise Reduction of PDP TV Using Multi-dimensional Spectral Analysis Method)

  • 양인형;정재은;곽형택;오재응
    • 한국소음진동공학회논문집
    • /
    • 제21권1호
    • /
    • pp.81-88
    • /
    • 2011
  • The method is introduced for estimating the noise source contribution on the noise of PDP TV in a multiple-input system where the input sources may be coherent with each other. By the coherence function method, it is found that the biggest part of the noise source in the PDP TV noise is generated by the PCB boards which consume high power and produce high heat. This analysis is modeled as three-input/single-output system because the noise is generated by three main boards, X-board, Y-board, SMPS that are located close to each other. The coherence function method is proved to be useful tool for identifying of noise source. In this study, Transfer Path Analysis using MDSA is implemented to determine the quantitative noise contribution of each board for PDP TV with the rear case closed and with the rear case open. And the possibility of noise reduction is confirmed through the experimental method that isolates the most contributing board by adding sound-absorbing materials to it.

보일러빌딩 내부 환기현상에 관한 수치적 연구 (Numerical Study on the Ventilation Effect in the Boiler Building)

  • 김철환;유근종;최훈기
    • 한국산업보건학회지
    • /
    • 제15권3호
    • /
    • pp.239-249
    • /
    • 2005
  • Ventilation effect is analyzed for boiler building with multiple heat sources. Air flow inside the boiler building is characterized as turbulent mixed convection. Analysis methodology is set up with two different $k-{\varepsilon}$ type models (standard $k-{\varepsilon}$, RNG $k-{\varepsilon}$). Two different cases with high and low outside temperature are analyzed. In case of high outside temperature condition, mixed convection is well realized inside the boiler building. With different upper louver opening rate, air flow is also well established and proper opening rate is found to meet design limit in case of low outside temperature condition. Difference of analysis results for two different turbulence models are not significant. Therefore, analysis methodology with simple $k-{\varepsilon}$ turbulence model is found to be reliable for the boiler building ventilation analysis. However, more simplified geometrical model is desired to expand its application.

열에너지 저장 암반공동의 형상 및 레이아웃 설계 가이드라인 (Guidelines for Designing the Shape and Layout of Thermal Energy Storage (TES) Rock Caverns)

  • 박도현;박의섭
    • 터널과지하공간
    • /
    • 제25권2호
    • /
    • pp.115-124
    • /
    • 2015
  • 열에너지 저장은 고온 또는 저온의 잉여 열에너지를 저장하여 수요 발생 시 사용하기 위한 기술로서 에너지의 수요와 공급 사이의 불균형을 해소하고, 이를 통해 에너지 시스템의 효율을 향상시킬 수 있다. 특히 간헐적인 신재생에너지 자원을 열에너지 형태로 변환하거나 저장함으로써 에너지 믹스에서 신재생에너지의 비중을 제고할 수 있으며, 이를 위해서는 열에너지 저장 장치와의 조합이 반드시 필요하다. 지하 암반공동을 이용한 열에너지 저장은 높은 건설비용이 수반되어 그 활용이 제한적이지만, 대규모의 열에너지를 장기간 저장할 수 있는 가장 현실적인 방법이다. 또한 기후조건에 따라 외부로의 열손실이 영향을 받는 지상의 열저장소와는 달리, 열저장 지하 암반공동은 장기 운영 시 주변 암반의 히팅에 따른 열손실의 감소를 기대할 수 있다. 본고에서는 열저장 암반공동의 형상 및 다중배치 설계 시 고려해야 할 주요 인자들을 소개하고, 저장공간의 설계에 대한 가이드라인을 제안하였다.

온실가스 감축 및 지속가능 미래를 위한 집단에너지사업 방향 (Current and Future Trends of District Heating System for a Sustainable Future and Greenhouse Gas Reduction)

  • 정민정;박진규;안덕용;이남훈
    • 한국기후변화학회지
    • /
    • 제8권4호
    • /
    • pp.377-384
    • /
    • 2017
  • Amid growing concerns about energy security, energy prices, economic competitiveness, and climate change, district heating (DH) system has been recognized for its significant benefits and the part it can play in efficiently meeting society's growing energy demands while reducing environmental impacts. Policy makers often need to quantify the fuel and carbon dioxide ($CO_2$) emissions savings of DH system compared to conventional individual heating (IH) system in order to estimate its actual emissions reductions. The objective of this paper is to calculate energy efficiency and $CO_2$ emissions saving, and to propose the future direction for DH system in Korea. DH system achieved total system efficiencies of 67.9% compared to 54.1% for IH system in 2015. DH system reduced $CO_2$ emissions by $381,311ton-CO_2$ (4.1%) compared to IH system. The results suggest that DH system is more preferred than IH system using natural gas. In Korea, the aim is to reduce dependence on fossil fuels and to use energy more efficiently. DH system have significant potential with regard to achieving this aim, because DH system are already integrated with power generation in the electricity since combined heating and power (CHP) are used for heat supply. Although the future conditions for DH may look promising, the current DH system in Korea must be enhanced in order to handle future competition. Thus, the next DH system must be integrated with multiple renewable energy and waste heat energy sources.

Three Cases with the Multiple Occurrences of Freezing Rain in One Day in Korea (12 January 2006; 11 January 2008; and 22 February 2009)

  • Park, Chang-Kyun;Byun, Hi-Ryong
    • 대기
    • /
    • 제25권1호
    • /
    • pp.31-49
    • /
    • 2015
  • From the hourly data of 75 Korean weather stations over a 12-year period (2001~2012), this study has chosen three cases (January 12, 2006; January 11, 2008; and February 22, 2009) of multiple freezing rains and investigated the atmospheric circulations that seemed to cause the events. As a result, the receding high pressure type (2006), prevailing high pressure type (2008), and warm front type (2009) are confirmed as synoptic patterns. In all three cases, freezing rain was found in regions with a strong ascending current near the end point of a low-level jet that carried the warm humid air from low latitudes. The strong ascending current resulted from lower-level convergence and upper-level divergence. In 2006 and 2009, the melting process was confirmed. In 2008, the supercooled warm rain process (SWRP) was confirmed. In contrast to existing SWRP theory, it was found that the cool air produced at the middle atmosphere and near the earth's surface led to the formation of freezing rain. The sources of this cool air were supposed to be the evaporative latent heat and the cold advection coming from the northeast. On the other hand, a special case was detected, in which the freezing rain occurred when both the soil surface temperature and surface air temperature were above $0^{\circ}C$. The thickness distributions related to freezing rain in Korea were found to be similar to those in North America. A P-type nomogram was considered for freezing rain forecasting; however, it was not relevant enough to Korea, and few modifications were needed.

Physiochemical Characteristics of Lactobacillus acidophilus KH-l Isolated from the Feces of a Breast-Fed Infant

  • Yu, K.H.;Kang, S.N.;Park, S.Y.
    • Preventive Nutrition and Food Science
    • /
    • 제10권4호
    • /
    • pp.333-339
    • /
    • 2005
  • Three lactobacillus strains, two from infant feces, and one from cow's milk, were selected among 172 isolates, from multiple sources, for further study based on the antimicrobial activities against six strains of pathogenic bacteria and identified as Lactobacillus acidophilus. The strains revealed a wide scope of spectrum against pathogenic bacteria. Viable Lactobacillus acidophilus KH-l cell counts at pH 2.0 were slightly decreased to $1.42\times10^7$ CFU/mL from $4.18\times10^7$ CFU/mL, while remaining at $3.42\times10^7$ CFU/mL at pH 4.0 with the survival rate of $33.97\%\;and\;81.82\%$, respectively. At the concentration of $0.1\%$ oxgall, L acidophilus KH-l kept growing up to $3.12\times10^7$ CFU/mL with a mean growth rate constant (k) of 0.25, and cell number was slightly decreased to $1.21\times10^7$ CFU/mL (k=0.19) with $0.3\%$ oxgall, but remained at $7.6\times10^6$ CFU/mL (k=0.17) with $0.5\%$ oxgall. L. acidophilus KH-l had a $D_{60}$ value of 7.14, with viable cell numbers $1.4\times10^5$ CFU/mL after heat treatment at $60^{\circ}C$ for 30 minutes. Stability of L acidophilus KH-l at $-20^{\circ}C$ was significantly higher, when the strain was cultivated under the optimum growth temperature $(54.41\%\;and\;54.35\%)$ than at the temperature $(13.53\%)$.

데이터 탐색을 활용한 딥러닝 기반 제천 지역 산사태 취약성 분석 (Assessment of Landslide Susceptibility in Jecheon Using Deep Learning Based on Exploratory Data Analysis)

  • 안상아;이정현;박혁진
    • 지질공학
    • /
    • 제33권4호
    • /
    • pp.673-687
    • /
    • 2023
  • 데이터 탐색은 수집한 데이터를 다양한 각도에서 관찰 및 이해하는 과정으로 데이터 구조 및 특성 분석을 통해 데이터의 분포와 상관관계를 파악하는 과정이다. 일반적으로 산사태는 다양한 인자들에 의해 유발되고 발생 지역에 따라 유발 인자들이 미치는 영향이 상이하기 때문에 산사태 취약성 분석 이전에 데이터 탐색을 통해 유발 인자 사이의 상관관계를 파악하고 특징적인 유발 인자를 선별한다면 효과적인 분석을 수행할 수 있다. 따라서 본 연구는 데이터 탐색이 예측 모델의 성능에 미치는 결과를 확인하기 위해 두 단계에 걸친 데이터 탐색을 수행하여 인자를 선별하고, 선별된 유발 인자들 사이의 조합과 23개의 전체 유발 인자 조합을 활용하여 딥러닝 기반의 산사태 취약성 분석을 진행하였다. 데이터 탐색 과정에서는 Pearson 상관계수 heat map과 random forest의 인자 중요도 histogram을 활용하였으며, 딥러닝 기반 산사태 취약성 분석 결과의 정확도는 분석을 통해 획득한 산사태 취약 지수 값을 이용해 제작한 산사태 취약성 지도를 confusion matrix 기반의 정확도 검증 방법을 통해 분석하였다. 분석 결과, 전체 23개의 인자를 사용한 산사태 취약성 해석 결과는 55.90%의 낮은 정확도를 보였지만 한 단계의 탐색을 거쳐 선별한 13개 인자를 활용한 취약성 해석 결과는 81.25%의 분석 정확도를 보였고, 두 단계 데이터 탐색을 모두 수행하여 선별된 9개의 유발 인자를 활용한 산사태 취약성 분석 결과는 92.80%로 가장 높은 정확도를 보였다. 따라서 데이터 탐색을 통해 특징적인 유발 인자를 선별하고 분석에 활용하는 것이 산사태 취약성 분석에서 더 좋은 분석 성능을 기대할 수 있음을 확인하였다.

친환경에너지타운에서 보어홀지중열 저장(BTES) 활용 융복합 열에너지 공급 시스템 사례 연구 (International Case Studies on the Eco-friendly Energy Towns with Hybrid Thermal Energy Supply System and Borehole Thermal Energy Storage (BTES))

  • 심병완
    • 자원환경지질
    • /
    • 제51권1호
    • /
    • pp.67-76
    • /
    • 2018
  • 본 연구는 해외 친환경에너지타운에서 보어홀 지중열 저장(BTES) 기술을 활용한 융복합 열에너지 공급 시스템의 3가지 사례로서 캐나다의 ADEU(Alexandra District Energy Utility) 및 DLSC(Drake Landing Solar Community)와 덴마크의 Brædstrup Solpark를 조사하였다. 이들 지역 냉난방 시스템들은 효율과 지속가능성을 높이기 위하여 다중 에너지원을 활용하고 있다. ADEU는 리치몬드시에서 726 개의 지중열교환기로 이루어진 지열필드 및 천연 가스 백업 보일러를 이용한 대규모 지역에너지 공급을 위해 개발되었다. 그리고 캘거리시 인근 Okotoks에 위치한 DLSC는 여름철에 풍부한 태양열 에너지를 144 개의 지중열교환기를 통하여 지중에 저장하고 겨울철 난방을 위해 각 주택에 열에너지를 분배하는 계간축열 방식의 지역난방 시스템이다. Brædstrup Solpark 지역난방 시스템은 태양열, 히트 펌프, 보일러 플랜트 및 계간축열을 위한 48 개의 지중열교환기로 구성되며 다중 에너지원을 이용하여 열을 저장한다. BTES 시추공의 심도와 축열량은 지하수 유동과 지반의 열물성에 따라 영향을 많이 받는다. 이러한 시스템들은 경쟁력 있는 에너지 가격으로 장기적인 에너지를 공급함으로서 신뢰성과 경제성을 평가 받았다. 그리고 ADEU와 Brædstrup Solpark는 서비스 영역 확장을 위한 장기 에너지 공급 계획을 기반으로 확장이 진행중이다. 본 조사를 통하여 이러한 시스템들은 사회 경제적인 이익 뿐만아니라 환경적인 관점이 설계에 반영되어 있는 것을 알 수 있었다. 국내에서도 이러한 프로젝트를 실시하기 위해서는 지방 정부 또는 관련 기관의 에너지 정책 지원 뿐만아니라, 관리 기관 설치를 통한 장기적인 협력이 필요하다.