• Title/Summary/Keyword: multilevel analysis

Search Result 331, Processing Time 0.024 seconds

Multilevel Analysis of Factors Related to Cost and Length of Stay in Acute Myocardial Infarction Patients with Coronary Stenting: Based on Korean National Health Insurance Service's Customized Database in 2010 and 2015 (관상동맥 스텐트를 삽입한 급성 심근경색 환자의 진료비 및 재원일수 관련 요인에 대한 다수준분석: 2010년과 2015년 국민건강보험공단 맞춤형 데이터베이스 자료를 바탕으로)

  • Choi, Boyoung;Lee, Hae-Jong
    • Health Policy and Management
    • /
    • v.30 no.3
    • /
    • pp.418-429
    • /
    • 2020
  • Background: This study aims to analyze the cost and the length of stay (LOS) of acute myocardial infarction (AMI) patients with coronary artery stenting according to the characteristics of individuals and institutions. Methods: The data was collected from Korean National Health Insurance Service's customized database in 2010 and 2015. Chi-square test, t-test, analysis of variance, and multilevel analysis were performed. Results: The intraclass correlation coefficients for cost were 7.02% in 2010, 5.61% in 2015 and for LOS were 3.17%, 1.40%, respectively. The average costs were 9,067,000 won in 2010 and 9,889,000 won in 2015 (p<0.0001). However, the cost in 2015 was lower than the cost applying increased fee. The costs increased in aged 50-59 years, 60-69 years, and aged ≥70 years versus in aged under 49 years. The cost was higher in Charlson comorbidity index (CCI) 3 to 4 and ≥5 than in CCI 0. The costs were lower in male, medical aid recipients, metropolises, and local hospitals in other regions in 2010. LOS decreased from 8.1 days in 2010 to 7.4 days in 2015. It decreased in male, high income group, and the group of admission via emergency room. However, it increased in higher ages and medical aid recipients, and it also increased when CCI rose. The Internal Herfindahl Index was related to LOS in 2010. Conclusion: The variation of hospital level was small compared to the patient level. Therefore, it is important to implement applicable policies at the patient level in order to reduce cost and LOS of AMI patients.

The Output Characteristics Analysis by Cut-off Frequency Set-up of the LCR Filter on NPC Multi-Level Inverter with Trap-Filter (트랩필터를 갖는 NPC멀티레벨 인버터의 LCR필터 차단주파수 설정에 따른 출력특성 분석)

  • Kim, Soo-Hong;Kim, Yoon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.5
    • /
    • pp.892-897
    • /
    • 2007
  • This paper presents the output filter design and the output characteristic analysis by cut-off frequency set up of the LCR filter on NPC multi-level inverter with trap-filter. The single-phase NPC three-level inverter operates at low switching frequency. The proposed LC trap filter is comprised of a conventional LCR output filter, by using LC trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also. low damping resistor is increased the output filter system. The multilevel inverter system used NPC type inverter in proper system for high power application and controller is used DSP(TMS320C31). The effectiveness of proposed system confirmed the validity through SPICE simulation and experimental results.

Regional Factors on the Self-rated Health of Wage Workers

  • Kwon, Minjung;Choi, Eunsuk
    • Research in Community and Public Health Nursing
    • /
    • v.29 no.1
    • /
    • pp.21-32
    • /
    • 2018
  • Purpose: This study attempted to identify regional disparities of self-rated health among Korean wage workers and to investigate the influencing factors on them. Methods: The study subjects were 25,069 workers in 16 regions who were extracted from the 2014 Korean Working Condition Survey (KWCS). A multilevel analysis was conducted by building hierarchical data at individual and regional level. Results: In this study, 'financial autonomy rate' and 'current smoking rate' were identified as regional factors influencing the workers' self-rated health. When the socio-demographic and occupational factors of the workers were controlled, 'current smoking rate', a health policy factor, explained the regional disparity of workers' health status. Conclusion: We found that the health status of workers can be affected by the health behavior level of the whole population in their residential area. In order to improve the health status of working population and to alleviate their regional health inequalities, it is necessary to strengthen macro and structural level interventions.

Face seqmentation using automatic searching algorithm of thresholding value and statistical projection analysis (자동 임계점 탐색 알고리즘과 통계적 투영 분석을 이용한 얼굴 분할)

  • 김장원;이흥복;김창석
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.8
    • /
    • pp.1874-1884
    • /
    • 1996
  • In this paper, we proposed automatic searching algorithm of thresholding value using multilevel thresholding for face segmentation from input bust image effectively. The proposed algorithm extracted the thresholding value of brightness that is formed background region, face region and hair region without illumination, background and face size from input image. The statistical projection analysis project the brightness of multilevel thresholding image into horizontal and vertical direction and decide the thresholding value of face. And the algorithm extracted elliptical type block of face from input image in order to reduce the back ground region and hair region efficiently. The proposed algorithm can reduce searching area of feature extraction and processing time for face recognication.

  • PDF

Analysis of Line and Circular Contact Elastohydrodynamic Lubrication with Multigrid Multilevel Method (다중 격자 다중 차원법을 이용한 선접촉 또는 점접촉 탄성 유체 윤활 해석)

  • 장시열
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.323-330
    • /
    • 1999
  • The conventional analysis for the numerical computation of fluid film thickness with elastic deformation of contact region. is performed by Newton-Rephson method for its 18st convergence characteristics. However, both high load and relatively low sliding velocity frequently make it impossible for Newton-Rahpson method to get both converged and stable solutions. In particular, this method cannot provide converged Solution under the condition of high load above 1.0 GPa which frequently occurs in line contact of EHL problem. Multigird multi-level method for the solver of non-linear partial differential equation including solid deformation is preferred to Newton-Rshpson method for better convergence and stability and is applied to line contact EHL behavior in this study.

  • PDF

A Study on Filter Efficiency Analysis and Harmonic Reduction of Single Phase NPC Multi-Level Inverter with LC-Trap Filter (LC트랩필터를 갖는 단상 NPC 멀티레벨 인버터의 출력 고조파 저감 및 필터 효율 분석에 관한 연구)

  • Kim Soo-Hong;Seo Kang-Moon;Kim Yoon-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.8
    • /
    • pp.430-435
    • /
    • 2006
  • This paper presents a method about the efficiency analysis and the harmonic reduction of single phase NPC multi-level inverter with LC-trap filter and LCR output filter. The proposed LC-trap filter is comprised of a conventional LC output filter, by using LC-trap filter the need for high damping resistor and low LC cut-off frequency is eliminated. Also, low damping resistor is increased the efficiency of the output filter. Experimental verification of the proposed circuit is provided with single phase NPC multilevel inverter system and DSP controller.

Power Loss and Junction Temperature Analysis in the Modular Multilevel Converters for HVDC Transmission Systems

  • Wang, Haitian;Tang, Guangfu;He, Zhiyuan;Cao, Junzheng
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.685-694
    • /
    • 2015
  • The power loss of the controllable switches in modular multilevel converter (MMC) HVDC transmission systems is an important factor, which can determine the design of the operating junction temperatures. Due to the dc current component, the approximate calculation tool provided by the manufacturer of the switches cannot be used for the losses of the switches in the MMC. Based on the enabled probabilities of each SM in an arm, the current analytical models of the switches can be determined. The average and RMS currents can be obtained from the corresponding current analytical model. Then, the conduction losses can be calculated, and the switching losses of the switches can be estimated according to the upper limit of the switching frequency. Finally, the thermal resistance model of the switches can be utilized, and the junction temperatures can be estimated. A comparison between the calculation and PSCAD simulation results shows that the proposed method is effective for estimating the junction temperatures of the switches in the MMC.

Circulating Current Harmonics Suppression for Modular Multilevel Converters Based on Repetitive Control

  • Li, Binbin;Xu, Dandan;Xu, Dianguo
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1100-1108
    • /
    • 2014
  • Modular multilevel converters (MMCs) have emerged as the most promising topology for high and medium voltage applications for the coming years. However, one particular negative characteristic of MMCs is the existence of circulating current, which contains a dc component and a series of low-frequency even-order ac harmonics. If not suppressed, these ac harmonics will distort the arm currents, increase the power loses, and cause higher current stresses on the semiconductor devices. Repetitive control (RC) is well known due to its distinctive capabilities in tracking periodic signals and eliminating periodic errors. In this paper, a novel circulating current control scheme base on RC is proposed to effectively track the dc component and to restrain the low-frequency ac harmonics. The integrating function is inherently embedded in the RC controller. Therefore, the proposed circulating current control only parallels the RC controller with a proportional controller. Thus, conflicts between the RC controller and the traditional proportional integral (PI) controller can be avoided. The design methodologies of the RC controller and a stability analysis are also introduced. The validity of the proposed circulating current control approach has been verified by simulation and experimental results based on a three-phase MMC downscaled prototype.

11-kV Series-Connected H-Bridge Multilevel Converter for Direct Grid Connection of Renewable Energy Systems

  • Islam, Md. Rabiul;Guo, Youguang;Zhu, Jian Guo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.2
    • /
    • pp.70-78
    • /
    • 2012
  • Due to the variable nature of renewable energy resources and power demand by consumers, it is difficult to operate a power system installed with only one type of renewable energy resource. Grid-based renewable generation may be the only solution to overcome this problem. The conventional approach based on a low-voltage converter with power frequency transformer is commonly employed for grid connection of offshore renewable energy systems. Because of the heavy weight and large size of the transformer, the system can be expensive and complex in terms of installation and maintenance. In this paper, an 11-kV series connected H-bridge (SCHB) multilevel voltage source converter (VSC) is proposed to achieve a compact and light direct grid connection of renewable energy systems. This paper presents the design, simulation and analysis of a five level (5L)-SCHB and an eleven level (11L)-SCHB VSC for 11-kV grid-based renewable energy systems. The performance, cost, modulation scheme and harmonic spectra of the converter are analyzed.

Line Current Characteristics of Multilevel H-Bridge Inverters: Part I - Connection of Input Transformer and Phase Shift Characteristics (다단 H-브릿지 인버터의 입력전류특성 (I) - 입력단 변압기 결선과 위상이동특성)

  • Jeong, Seung-Gi
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.13 no.3
    • /
    • pp.229-236
    • /
    • 2008
  • Recently, multilevel H-bridge inverters have become popular in medium to high power ac drive applications. One of significant advantages of them is low harmonic contents in their input line currents thanks to the transformer with multiple phase-shifted secondary windings. This paper attempts to provide basic guidelines for the design of the phase shifting transformer windings and theoretical analysis of input line current harmonics of H-bridge inverters. The part I provides the derivation of basic relationships between input and output current of the transformer and the relationship between the phase shifting characteristics and design aspects of the transformer.