• 제목/요약/키워드: multifrequency

검색결과 46건 처리시간 0.016초

Comparison of Infiltration Induced in Veins of Rabbit's Ear and Human's Forearm by Using Bioelectrical Impedance: Pilot Study

  • Kim, Jae-Hyung;Hwang, Young-Jun;Kim, Gun-Ho;Shin, Beum-Joo;Kim, Yong-Jin;Lee, Eun-Joo;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.306-313
    • /
    • 2017
  • An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a rabbit's ear, impedance parameters showed significant difference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit's ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltrated intravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein of a human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_c$ graph, the positions in infiltration induced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human's forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infiltration early in a noninvasive and quantitative manners.

Body Composition Variations in the Paretic and Nonparetic Regions of Patients with Strokes Caused by Cerebral Hemorrhage or Cerebral Infarction

  • Yoo, Chan-Uk;Kim, Jae-Hyung;Kim, Gun-Ho;Hwang, Young-Jun;Jeon, Gye-Rok;Baik, Seong-Wan
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.314-323
    • /
    • 2017
  • Indicators to quantitatively evaluate the body function may help to optimize the effectiveness of rehabilitation therapy for stroke patients. In this study, we analyzed the body composition in the paretic and nonparetic regions of stroke patients with hemiplegia caused by cerebral hemorrhage (7 cases) and cerebral infarction (13 cases) using multifrequency bioelectrical impedance. Specifically, we considered fat mass (FM), fat-free mass (FFM), FFMI index (FFMI), FM/FFM relation, body cell mass (BCM), basal metabolic rate (BMR), and BMR/FFM relation to evaluate the bodily function in the paretic and nonparetic regions. These values showed considerable differences according to grades determined by the stroke causes and the paralysis status. In the paretic regions, the FFM, FFMI, BCM, and BMR were low and the FM was high. In contrast, the nonparetic regions showed a high FFM and low FM. Furthermore, the paretic and nonparetic regions of all patients suitably fit a linear relation (slope: 22.17 kcal/day/kg) between BMR and FFM. Therefore, bio-electrical impedance measurements can be very useful to quantitatively assess paretic and nonparetic regions in hemiplegic stroke patients.

A Study on Obesity-promoting Factors for the Elementary School Chirdren

  • Cheong, Min-Shon;Kim, Ok-Hyun;Cha, Ki-Chul;Kim, Jung-Hee
    • 대한지역사회영양학회지
    • /
    • 제2권5호
    • /
    • pp.680-686
    • /
    • 1997
  • The purpose of this study is to examine the relationships among body composition, dietary intake, exercise, and life style in children(M=80, f=102) of the 5th and 6th grades of elementary school. Anthropometry and multifrequency bioelectrical impedance analysis were conducted to estimate body composition. Dietary intake, exercise, and life style were determined by using questionnaires. When obesity was classified greater than 120% of the ideal body weight, the prevalence rates of obesity were 31.2% for boy and 20.6% for girl. There were significant differences in body composition between nonobese(NO) and obese(OB) groups. Mean fat mass(FM) and lean body mass(LBM) were 8.6kg and 27.7kg for NO group and 16.7kg and 32.3kg for OB group, respectively. Also a significant difference was found in hydration rate(TBW/body weight)between groups( <0.01). No significant difference was found I total calorie intake and nutrient intakes between groups. No difference was found in the frequency and duration of outdoor exercise and indoor activities. Mean sleeping hours was 8-9hours for 62% of nonobese children and for 59% of obese children. However, calorie intake per body weight was significantly lower inobese children than in nonobese. The present study showed that significant differences existed in their body size and composition between NO and OB groups , while no differences existed in daily calorie intake, excercise , and life style. This may indicate that important obesity-promoting factors of early onset obesity may rely on other factors such as hereditary or environmental factors besides factors considered. Further studies are required to understand obesity-promoting factors in children. (Korean J Community Nutrition 2(5) : 680∼686, 1997)

  • PDF

바이오센서를 위한 PC 기반의 휴대용 고속 임피던스 분석기 개발 (Development of PC-based and portable high speed impedance analyzer for biosensor)

  • 김기련;김광년;허승덕;이승훈;최병철;김철한;전계록;정동근
    • 센서학회지
    • /
    • 제14권1호
    • /
    • pp.33-41
    • /
    • 2005
  • For more convenient electrode-electrolyte interface impedance analysis in biosensor, a stand-alone impedance measurement system is required. In our study, we developed a PC-based portable system to analyze impedance of the electrochemical cell using microprocessor. The devised system consists of signal generator, programmable amplifiers, A/D converter, low pass filter, potentiostat, I/V converter, microprocessor, and PC interface. As a microprocessor, PIC16F877 which has the processing speed of 5 MIPS was used. For data acquisition, the sampling rate at 40 k samples/sec, resolution of 12 bit is used. RS-232 with 115.2 kbps speed is used for the PC communication. The square wave was used as stimuli signal for impedance analysis and voltage-controlled current measurement method of three-electrode-method were adopted. Acquired voltage and current data are calculated to multifrequency impedance signal after Fourier transform. To evaluate the implemented system, we set up the dummy cell as equivalent circuit of which was composed of resistor, parallel circuit of capacitor and resistor connected in parallel and measured the impedance of the dummy cell; the result showed that there exist accuracy within 5 % errors and reproduction within 1 % errors compared to output of Hioki LCR tester and HP impedance analyzer as a standard product. These results imply that it is possible to analyze electrode-electrolyte interface impedance quantitatively in biosensor and to implement the more portable high speed impedance analysis system compared to existing systems.

Interferometric Monitoring of Gamma-Ray Bright AGNs: 4C +28.07 and Its Synchrotron Self-Absorption Spectrum

  • Myoung-Seok Nam;Sang-Sung Lee;Whee Yeon Cheong
    • 천문학회지
    • /
    • 제56권2호
    • /
    • pp.231-252
    • /
    • 2023
  • We present the analysis results of the simultaneous multifrequency observations of the blazar 4C +28.07. The observations were conducted by the Interferometric Monitoring of Gamma-ray Bright Active Galactic Nuclei (iMOGABA) program, which is a key science program of the Korean Very Long Baseline Interferometry (VLBI) Network (KVN). Observations of the iMOGABA program for 4C +28.07 were conducted from 16 January 2013 (MJD 56308) to 13 March 2020 (MJD 58921). We also used γ-ray data from the Fermi Large Array Telescope (Fermi-LAT) Light Curve Repository, covering the energy range from 100 MeV to 100 GeV. We divided the iMOGABA data and the Fermi-LAT data into five periods from 0 to 4, according to the prosody of the 22 GHz data and the presence or absence of the data. In order to investigate the characteristics of each period, the light curves were plotted and compared. However, a peak that formed a hill was observed earlier than the period of a strong γ-ray flare at 43-86 GHz in period 3 (MJD 57400-58100). Therefore, we assumed that the minimum total CLEANed flux density for each frequency was quiescent flux (Sq) in which the core of 4C +28.07 emitted the minimum, with the variable flux (Svar) obtained by subtracting Sq from the values of the total CLEANed flux density. We then compared the variability of the spectral indices (α) between adjacent frequencies through a spectral analysis. Most notably, α22-43 showed optically thick spectra in the absence of a strong γ-ray flare, and when the flare appeared, α22-43 became optically thinner. In order to find out the characteristics of the magnetic field in the variable region, the magnetic field strength in the synchrotron self-absorption (BSSA) and the equipartition magnetic field strength (Beq) were obtained. We found that BSSA is largely consistent with Beq within the uncertainty, implying that the SSA region in the source is not significantly deviated from the equipartition condition in the γ-ray quiescent periods.

L, C, X-밴드 다편파 레이더 산란계를 이용한 논 벼 생육인자 추정 (Estimation of Paddy Rice Growth Parameters Using L, C, X-bands Polarimetric Scatterometer)

  • 김이현;홍석영;이훈열
    • 대한원격탐사학회지
    • /
    • 제25권1호
    • /
    • pp.31-44
    • /
    • 2009
  • 본 연구에서는 다편파 산란계 시스템을 이용하여 얻어진 후방산란계수의 연중 변화를 편파와 입사각에 따라 알아보고 벼 생육인자와의 관계를 통하여 생육인자를 추정하고자 하였다. 2007년도 국립농업과학원 시험포장에 다편파산란계 시스템(L, C, X-band 안테나, 네트워크분석기, RF cable, 입사각 $20^{\circ}{\sim}60^{\circ}$)을 제작 구축하고 벼 이앙기에서 수확기까지 산란특성을 주기적으로 관측하였으며 레이더 방정식을 이용하여 후방산란계수를 계산하여 자료 분석에 사용하였다. 모든 안테나 밴드에서 벼 생육초기(5월말$\sim$6월초)에는 VV-편파가 HH-, HV-편파보다 후방산란계수가 높게 나타났다. C-band의 경우 모든 입사각에서 벼가 자라면서 HH-편파 후방산란계수가 증가하다가 출수기(8월중순경)에 가장 높았고 그 이후 감소하는 경향이었다. X-band는 모든 편파의 후방산란계수가 벼 유수형성기(7월말경)까지 증가하다가 그 후 감소하였으며 등숙기인 9월 중순 이후 다시 증가하는 dual-peak 현상을 보였는데, 특히 VV-편파의 경우 9월 초순부터 후방산란계수 종가가 다른 편파에 비해 크게 나타났다. 파장별 밴드, 편파, 입사각도별 후방산란계수와 작물 생육과의 관계를 분석한 결과 L-band는 바이오매스와의 상관이 높게 나타났고 C-band에서는 엽면적지수와 초장과의 상관이 높게 나타났으며 X-band는 이삭 건물중과 상관이 높게 나타났다 후방산란계수를 이용하여 생육을 추정할 수 있는 회귀식을 작성하고 실측값과의 비교를 통하여 작물 생육 추정을 위한 최적 조건을 구명하였다.