• Title/Summary/Keyword: multi-simultaneous analysis

Search Result 140, Processing Time 0.025 seconds

Slope Stability Analysis Considering Multi Failure Mode (다중파괴모드를 고려한 사면안정해석)

  • Kim, Hyun-Ki;Kim, Soo-Sam
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.1
    • /
    • pp.24-30
    • /
    • 2011
  • Conventional slope stability analysis is focused on calculating minimum factor of safety or maximum probability of failure. To minimize inherent uncertainty of soil properties and analytical model and to reflect various analytical models and its failure shape in slope stability analysis, slope stability analysis method considering simultaneous failure probability for multi failure mode was proposed. Linear programming recently introduced in system reliability analysis was used for calculation of simultaneous failure probability. System reliability analysis for various analytical models could be executed by this method. For application analysis for embankment, the results of this method shows that system stability of embankment calculate quantitatively.

골프장 농약 검사를 위한 다성분동시시험방법 확립에 관한 연구

  • 이민효;노회정;박종겸;윤정기;김찬섭
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.81-85
    • /
    • 2002
  • The possibility of simultaneous analysis of 24 pesticides out of 30 residual pesticides which are subjected to test in the golf courses was examined. The utility of the simultaneous analysis of multi-residue pesticides was evaluated by recovery test through a standard addition method of pesticides in water, soil, and lawn grass. The experimental results of the recovery rates for individual pesticides are as follows : The number of pesticide of which average recovery was over 70% regardless of medium was 16 pesticides. These pesticides were composed of 8 organophosphorus pesticides(Chlorpyrifos, Chlorpyrifos-methyl, Diazinon, EPN, Fenitrothion, Phenthoate, Phosalone, and Toclofos-methyl). 4 organochlorinated pesticides(Daconil, Captan, Endosulfan, and Tetradifon), 2 pyrethroid pesticides(Fepropathrin, Lambda-cyhalothrin) and 2 other pesticides(Bromopropylate, Pendimethalin). On the other hand, in case of Dicofol, average recovery by medium was over 70% for water and lawn grass but was only 53.3% for soil. Therefore, the simultaneous analytical method applied in this experiment is not appropriate for analysis of Dicofol in soil. Furthermore, among 7 pesticides, 2 pesticides(Amitraz and Pyraclofos) showed that theirs average recovery rates deviated from criteria(70~130%) at almost all media, while 5 pesticides(Bensulide, Deltamethrin, Iprodione, Phosphamidon and Tralomethlin) were not detected from all media by selected GC detector(NPD or ECD).

  • PDF

Optimum Design of a Simple Slope considering Multi Failure Mode (다중 파괴모드를 고려한 단순 사면의 최적 설계)

  • Kim, Hyun-Ki;Shin, Min-Ho;Choi, Chan-Yong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.73-80
    • /
    • 2010
  • Conventional slope stability analysis is focused on calculating minimum factor of safety or maximum probability of failure. To minimize inherent uncertainty of soil properties and analytical model and to reflect various analytical models and its failure shape in slope stability analysis, slope stability analysis method considering simultaneous failure probability for multi failure mode was proposed. Linear programming recently introduced in system reliability analysis was used for calculation of simultaneous failure probability. System reliability analysis for various analytical models could be executed by this method. Optimum design to determine angle of a simple slope is executed for multi failure mode using linear programming. Because of complex consideration for various failure shapes and modes, it is possible to secure advanced safety by using simultaneous failure probability.

Simultaneous Multi-Channel Sensor System for Gas Flow Measurementtion Measurement

  • Kim, Young-Han;Joung, Ok-Jin
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.95.3-95
    • /
    • 2002
  • A multi-channel electrostatic probe is utilized to determine gas flow rate in a cylindrical container. A numerical analysis is conducted to compare experimental measurement with the computed gas velocity in radial and axial directions.

  • PDF

A Quantitative Decision-making Analysis Using Fuzzy Theory in Nuclear Power Plants

  • Moosung Jae;Moon, Joo-Hyun
    • International Journal of Reliability and Applications
    • /
    • v.2 no.2
    • /
    • pp.137-146
    • /
    • 2001
  • In general, analysis of the decision problems in nuclear system management involves a simultaneous consideration of various criteria and decision alternatives. Sometimes, it is a complex, unstructured, ill-defined process incorporating the multi-criteria and the data of impreciseness. To cope with this analysis, a fuzzy hierarchical analysis methodology is proposed and demonstrated with a simple example.

  • PDF

Multi-Phase Optimization of Quill Type Machine Structures(1) (Static Compliance Analysis & Multi-Objective Function Optimization) (퀼형 공작기계구조물의 다단계 최적화(1) (정강성 해석 및 다목적함수 최적화))

  • Lee, Yeong-U;Seong, Hwal-Gyeong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.11
    • /
    • pp.155-160
    • /
    • 2001
  • To achieve high precision cutting as well as production capability in the machine tool, it is needed to develop excellent rigidity statically, dynamically and thermally as well. In order to predict the qualitative behavior of a machine tool, simultaneous analysis of mechanics and heat transfer is required. Generally, machine tool designers have solved designing problems based on partial estimation of the specified rigidity. This study clears the inter-relationship between therm, and propose multi-phase optimization of machine tool structure using a genetic algorithm. The multi-phase solution method is consists of a series of mechanical design problem. At this first phase of static design problem, multi-objective optimization for the purpose of minimization of the total weight and static compliance minimization is solved using the Pareto Genetic Algorithm.

  • PDF

Reliability Analysis in Designing of Reinforced Soil Structures using Uni-Modal Bounds (단일모드 구간해법을 이용한 보강토옹벽 설계의 신뢰성해석)

  • Kim, Hyun-Ki;Lee, Sung-Hyouk;Choi, Chan-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.9 no.4
    • /
    • pp.17-25
    • /
    • 2010
  • Evaluation of stability in traditional designing of reinforced soil structures is executed by examination of internal and external stability. Analysis of internal stability is for pull-out and ductile strength. Analysis of external stability is for settlement, overturning and sliding. To minimize inherent uncertainties of soil properties and analytical model, reliability analysis was developed recently. In this study, reliability analysis method considering simultaneous failure probability for various failure mode of internal and external stability is proposed. By applying uni-modal bounds, Stability of system reliability of reinforced soil structures is evaluated by integrating multi failure mode for various analytical model. Because of complex consideration for various failure shapes and modes, it is possible to secure advanced safety by using simultaneous failure probability. And evaluation of reinforced soil structure is executed by representative index, simultaneous failure probability, than previous method.

  • PDF

Simultaneous observations of the H2O and SiO masers toward the late-type stars using KVN

  • Yun, Youngjoo;Cho, Se-Hyung;Kim, Jaeheon;Choi, Yoon Kyung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.59.2-59.2
    • /
    • 2015
  • We present the results of simultaneous observations of the H2O and SiO masers emitted from the circumstellar envelopes of the late-type stars. These observations have been carried out at the K and Q bands using KVN since 2014 August and were scheduled to test the feasibility of multi-frequency phase referencing analysis on the maser lines. In order to increase the accuracy of group delay solution in the fringe search on the continuum source, the IF channels were randomly distributed within the available bandwidth of 500 MHz in each band. The positions of all maser spots are relatively described with respect to the position of the reference continuum source through the source frequency phase referencing technique, and this provides the astrometric position accuracy. Therefore, the relative locations of the H2O maser spots with respect to the SiO maser spots are determined from our observations, and the capability of the simultaneous multi-band observation of KVN is proved to be powerful to study the maser pumping mechanism around the late-type stars.

  • PDF

Analytical Quality by Design Methodology Approach for Simultaneous Quantitation of Paeoniflorin and Decursin in Herbal Medicine by RP-HPLC Analysis

  • Kim, Min Kyoung;Park, Geonha;Hong, Seon-Pyo;Jang, Young Pyo
    • Natural Product Sciences
    • /
    • v.27 no.4
    • /
    • pp.264-273
    • /
    • 2021
  • Simultaneous quantification of multiple marker compounds in herbal medicine by high performance liquid chromatography (HPLC) analysis is still a challenge due to the complexity in various parameters to be considered and co-existing multi-components. As a case study, a reliable HPLC method for simultaneous quantification of paeoniflorin from Paeoniae Radix and decursin from Angelicae Gigantis Radix in various commercial herbal medicine was developed based on analytical quality by design (AQbD) strategy. As a first step, risk assessment was performed to select the critical method parameters (CMPs) which were decided as organic mobile phase ratio and column oven temperature. In order to evaluate the effect of the CMPs on critical method attributes (CMAs) of peak resolution and tailing, central composite design (CCD) was employed. The final chromatographic conditions were optimized as follows: column- C18, 4.6 × 250 mm, 5 ㎛ particle size; mobile phase- A: acetonitrile, B: 0.1% acetic acid water; detection wavelength- 235 nm for paeoniflorin, 325 nm for decursin; column oven temperature- 25℃; flow rate- 1.0 mL/min; gradient mobile phase system as Time (min) : % A, 0:14, 25:14, 30:50, 60:50, 61:100, 65:100, 66:14, 75:14. The method was successfully validated according to the International Conference on Harmonization (ICH) guidelines and piloted for ten commercial herbal medicines.