• 제목/요약/키워드: multi-loop pickup coil.

검색결과 6건 처리시간 0.021초

Parallel-loop 검출코일을 가지는 단일층 YBCO dc-SQUID 자력계의 제작 및 특성 연구 (Fabrications and measurements of single layer YBCO dc-SQUID magnetometers designed with parallel-loop pickup coil)

  • 유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • 제5권1호
    • /
    • pp.45-49
    • /
    • 2003
  • We have designed and fabricated the single-layer high $T_{c}$ SQUID magnetometer consisting of a directly coupled grain boundary junction SQUID with an inductance of 100 pH and 16 nested parallel pickup coils with the outermost dimension of 8.8 mm ${\times}$ 8.8 mm. The magnetometer was formed from a YBCO thin film deposited on an STO(100) bicrystal substrate with a misorientation angle of $30^{\circ}$. The SQUID magnetometer was further improved by optimizing the multi-loop pickup coil design for use in unshielded environments. Typical characteristics of the dc SQUID magnetometer had a modulation voltage of 40 $\mu\textrm{V}$ and a white noise of $30fT/Hz^{1}$2/. The SQUID magnetometer exhibited a 1/f noise level at 10 Hz reduced by a factor of about 3 compared with that of the conventional solid type pickup coil magnetometers and a very stable flux locked loop operation in magnetically disturbed environments.s.

  • PDF

저잡음 심자도측정시스템 개발을 위한 고온초전도 SQUID 센서의 제작 (Fabrication of HTS SQUID Sensors for the Application to a High S/N Ratio Magnetocardiograph System)

  • 김인선;유권규;박용기
    • Progress in Superconductivity
    • /
    • 제6권1호
    • /
    • pp.19-23
    • /
    • 2004
  • YBCO do superconducting quantum interference device (SQUID) magnetometers based on bicrystal Josephson junctions on 10 mm ${\times}$ 10 mm $SrTiO_3$ substrates have been fabricated. The pickup coil of the device was designed to have 16 parallel loops with 50-fm-wide lines. We could obtain optimised direct coupled YBCO SQUID magnetometer design with field sensitivity $B_{N}$ $\Phi$/ of $4.5 nT/\Phi_{0}$ and magnetic field noise $B_{N}$ of about $22 fT/Hz^{1}$2/ with an I/f corner frequency of 2 Hz measured inside a magnetically shielded room. Preliminary results of magnetocardiograph measurement using the HTS SQUID magnetometers show signal to noise ratio of about 110, which is comparable to the quality of a commercial MCG system based on Nb-SQUIDs.

  • PDF

사파이어 기판을 사용한 병렬 검출코일 구조의 계단형 모서리 접합 SQUID 자력계 (YBCO step-edge junction dc SQUID magnetometers with multi-loop pickup coil fabricated on sapphire substrates)

  • 황태종;김인선;김동호;박용기
    • Progress in Superconductivity
    • /
    • 제5권2호
    • /
    • pp.94-97
    • /
    • 2004
  • Step-edge Josephson junctions (SEJ) have been fabricated on sapphire substrates with in situ deposited films of CeO$_2$ buffer layer and YBa$_2$Cu$_3$O$_{7}$ films on the low angle steps. Direct coupled SQUID magnetometers with the SEJ were formed on 1 cm X 1 cm R-plane sapphire substrates. Typical 5-${\mu}{\textrm}{m}$-wide Josephson junctions have R$_{N}$ of 3 Ω and I$_{c}$ of 50 $mutextrm{A}$ at 77 K. The direct coupled SQUID magnetometers were designed to have pickup coils of 50-${\mu}{\textrm}{m}$-wide 16 parallel loops on the 1 cm X 1 cm substrates with outer dimension of 8.8 mm X 8.8 mm. The SEJ SQUID magnetometers exhibit relatively low 1/f noise even with dc bias control, and could be stably controlled by flux-locked loops in the magnetically disturbed environment. Field noise of the do SQUID was measured to be 200∼300 fT/Hz$^{1}$2/in the white noise region and about 2 pT/Hz$^{1}$2/ at 1 Hz when measured with dc bias method.hod.d.

  • PDF