• 제목/요약/키워드: multi-loop PID controller

검색결과 18건 처리시간 0.026초

가동원전에서 공정모델링을 통한 PID 튜닝 시뮬레이션 방법 (A Simulation Method of PID Tuning with Process Modeling in Operating Nuclear Power Plants)

  • 민문기;정창규;이광현;이재기;김희제
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.290-294
    • /
    • 2014
  • PID(Proportional, Integral, Derivative) controller is the most popular process controllers in nuclear power plants. The optimized parameter setting of the process controller contributes to the stable operation and the efficiency of the operating nuclear power plants. PID parameter setting is tuned when new process control systems are installed or current process control systems are changed. When the nuclear plant is shut down, a lot of PID tuning methods such as the Trial and Error method, Ultimate Oscillation method operation, Ziegler-Nichols method, frequency method are used to tune the PID values. But inadequate PID parameter setting can be the cause of the unstable process of the operating nuclear power plant. Therefore the results of PID parameter setting should be simulated, optimized and finally verified. This paper introduces the simulation method of PID tuning to optimize the PID parameter setting and confirms them of the actual PID controller in the operating nuclear power plants. The simulation method provides the accurate process modeling and optimized PID parameter setting of the multi-loop control process in particular.

폐로식별기법에 의한 TRMS 모델링 (Modeling for Twin Rotor System Using CLID)

  • 이정경;권오규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.644-646
    • /
    • 2004
  • The closed loop identification(CLID) is a very useful method for on-line applications since it can identify the plant in the closed-loop system composed of the plant and the controller. There are some literatures on CLID, but they and mainly focused on SISO(Single-Input/Single-Output) problem. In this paper, a CLID method is proposed for MIMO(Multi-Input/Multi-Output) systems. The CLID method is applied to a MIMO benchmark plant, TRMS(Twin-Rotor MIMO System). To illustrate the performance of the closed-loop system identification., unit step responses in the TRMS are represented and compared with the open-loop identification via some simulation.

  • PDF

신경망 튜우닝에 의한 유량계통 동력 제어용 다변수 2-자유도 PID의 제어기 설계 (Design of Multivariable 2-DOF PID for Electrical Power of Flow System by Neural Network Tuning Method)

  • 김동화
    • 조명전기설비학회논문지
    • /
    • 제12권1호
    • /
    • pp.78-84
    • /
    • 1998
  • 발전소나 화학플랜트의 급수 및 순환수 계통은 물론 건물의 공조설비 유체계통, 정수 또는 폐수설비에서의 원수유량 및 약품 주입제어 등과 같은 유체계통은 대부분 밸브와 동력 펌프를 이용해 유량 제어를 한다. 따라서 이들 유체계통의 제어방법 및 정밀도에 따라 그 시스템의 성능 및 에너지 절약에 많은 영향을 미치게 된다. 지금까지 이들 계통은 주로 PI제어기를 이용하였으나 이 제어 방법으로는 루프간의 간섭현상으로 정밀하게 유량부하를 제어 할수 없는 문제점이 있다. 본 논문에서는 유체계통 동력부하 설비를 다변수로 구성하여 2-자유 PID제어를 적용하고 신경망을 이용해 튜우닝함으로서 효과적으로 정밀하게 제어 할수 있는 방법을 제시하고 시뮬레이션을 통해 그 방법의 우수성을 입증하였다. 시뮬레이션 결과 설정치를 잘 추종하고 외란에 대해서는 강인성을 갖는 것으로 나타났다.

  • PDF

PID Controller Tuning using Co-Efficient Diagram method for Indirect Vector Controlled Drive

  • Durgasukumar, G.;Rama Subba Redddy, T.;Pakkiraiah, B.
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권5호
    • /
    • pp.1821-1834
    • /
    • 2017
  • Medium voltage control applications due to obtain better output voltage and reduced electro-magnetic interference multi level inverter is used. In closed loop control with inverter, the PI controller does not operate satisfactorily when the operating point changes. This paper presents the performance of Co-Efficient diagram PI controller based indirect vector controlled induction motor drive fed from three-level inverter under different operating conditions (dynamic and steady state). The proposed Co-Efficient diagram PI controller based three level inverter significantly reduces the torque ripple compared to that of conventional PI controller. The performance of the indirect vector controlled induction motor drive has been simulated at different operating conditions. For three-level inverter control, a simplified space vector modulation technique is implemented, which reduces the coordinate transformations complications in the algorithms. The performance parameters, torque ripple contents and THD of induction motor drive with three-level inverter is compared under different operating conditions using CDM-PI and conventional PI controllers.

The position servo-loop in the robot control system must be processed every sampling period by real-time

  • Ha, Young-Youl;Lee, In-Ho;Kim, Min-Soo;Kim, Jae-Hoon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.121.1-121
    • /
    • 2002
  • Calculation unit and peripheral units that are used to make the position controller are embedded to one chip FPGA. $\textbullet$ Feed-forward PID controller and interpolator in the calculation unit mitigate frequent context switching. $\textbullet$ The peripheral units reduce the size of the joints position control board. $\textbullet$ Because the calculation unit is designed with pipeline structure, it has the advantages to apply to the multi joints.

  • PDF

이족보행로봇(IWR-III)의 통합 저어 환경 구축 (Implementation of Integrated Control Environment for Biped Robot(IWR-III))

  • 노경곤;서영섭;김진걸
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 G
    • /
    • pp.3089-3091
    • /
    • 1999
  • To control IWR-III Biped Waking Robot, those complex modules are necessary that concurrent control multi-axes servo motors, PID & Feedforward gain tuning, initial value calibration, display current status of system, user interface for emergency safety and three-dimensional rendering graphic visualization. It is developed for various-type gait $data^{[1]}$ and for control modes (i.e open/closed loop and pulse/velocity/torque control) that Integrated Control Enviroment with GUI( Graphic User Interface) consist of time-buffered control part using MMC (Multi-Motion Controller) and 3D simulation part using DirectX graphic library.

  • PDF

Identification and Multivariable Iterative Learning Control of an RTP Process for Maximum Uniformity of Wafer Temperature

  • Cho, Moon-Ki;Lee, Yong-Hee;Joo, Sang-Rae;Lee, Kwang-S.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2606-2611
    • /
    • 2003
  • Comprehensive study on the control system design for a RTP process has been conducted. The purpose of the control system is to maintain maximum temperature uniformity across the silicon wafer achieving precise tracking for various reference trajectories. The study has been carried out in two stages: thermal balance modeling on the basis of a semi-empirical radiation model, and optimal iterative learning controller design on the basis of a linear state space model. First, we found through steady state radiation modeling that the fourth power of wafer temperatures, lamp powers, and the fourth power of chamber wall temperature are related by an emissivity-independent linear equation. Next, for control of the MIMO system, a state space modeland LQG-based two-stage batch control technique was derived and employed to reduce the heavy computational demand in the original two-stage batch control technique. By accommodating the first result, a linear state space model for the controller design was identified between the lamp powers and the fourth power of wafer temperatures as inputs and outputs, respectively. The control system was applied to an experimental RTP equipment. As a consequence, great uniformity improvement could be attained over the entire time horizon compared to the original multi-loop PID control. In addition, controller implementation was standardized and facilitated by completely eliminating the tedious and lengthy control tuning trial.

  • PDF

Modelling a Stand-Alone Inverter and Comparing the Power Quality of the National Grid with Off-Grid System

  • Algaddafi, Ali;Brown, Neil;Rupert, Gammon;Al-Shahrani, Jubran
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권1호
    • /
    • pp.35-42
    • /
    • 2016
  • Developments in power electronics have enabled the widespread application of Pulse Width Modulation (PWM) inverters, notably for connecting renewable systems to the grid. This study demonstrates that a high-quality power can be achieved using a stand-alone inverter, whereby the comparison between the power quality of the stand-alone inverter with battery storage (off-grid) and the power quality of the utility network is presented. Multi-loop control techniques for a single phase stand-alone inverter are used. A capacitor current control is used to give active damping and enhance the transient and steady state inverter performance. A capacitor current control is cheaper than the inductor current control, where a small current sensing resistor is used. The output voltage control is used to improve the system performance and also control the output voltage. The inner control loop uses a proportional gain current controller and the outer loop is implemented using internal model control proportional-integral-derivative to ensure stability. The optimal controls are achieved by using the Sisotool tool in MATLAB/Simulink. The outcome of the control scheme of the numerical model of the stand-alone inverter has a smooth and good dynamic performance, but also a strong robustness to load variations. The numerical model of the stand-alone inverter and its power quality are presented, and the power quality is shown to meet the IEEE 519-2014. Furthermore, the power quality of the off-grid system is measured experimentally and compared with the grid power, showing power quality of off-grid system to be better than that of the utility network.