• 제목/요약/키워드: multi-generator

검색결과 413건 처리시간 0.029초

발전기 보호용 다기능 IED 시제품 H/W 구현에 관한 연구 (A Study on Implementation of Multi-Function Prototype IED H/W for Generator Protection)

  • 김윤상;안태풍;박철원
    • 조명전기설비학회논문지
    • /
    • 제27권12호
    • /
    • pp.74-80
    • /
    • 2013
  • Generator faults does not happen more often than the transmission and substation facility faults. However, impacts on the power system by generator faults are very large. In order to minimize the impact of generator faults, generator protection and control system with high reliability is required. Most of the generator relay in generator protection and control system of large power plant of Korea is operated by imports from abroad. Accordingly, in order to accumulate source technology and increase the import substitution effect, localization of multi-function generator protection IED is being developed. This paper deals with the implementation of a multi-function prototype IED H/W, which can be command and data exchange through communication for measuring, monitoring, protection and control. And the IED specification, various relay elements, measurement elements, communication functions, module function, and test system for the prototype IED H/W are described.

증기발생기 수위제어를 위한 다중 안정화 제어기 설계 (Reliable stabilizing multi-controller for steam generator level control)

  • 권현진;박상현;이상정;함창식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.1229-1232
    • /
    • 1996
  • This paper proposes the passive redundancy algorithm of multi-controller structure applicable to the steam generator level control system in the low power operating range. In the passive redundancy scheme of multi-controller structure, two suitable controllers exist if the plant is strongly stabilizable. One of the two controllers can be selected arbitrarily only if it is stable. In particular, this paper shows that the passive redundancy scheme can be efficiently used with PID and GPC control algorithms through simulation studies on the control of the steam generator.

  • PDF

퍼지다목적함수를 이용한 발전기보수유지계획의 수립 (The Generator Maintenance Scheduling using Fuzzy Multi-criteria)

  • 최재석;도대호;이태인
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1995년도 추계학술대회 학술발표 논문집
    • /
    • pp.131-138
    • /
    • 1995
  • A new technique using integer programming based on fuzzy multi-criteria function is proposed for generator maintenance scheduling. Minimization maintenance delay cost and maximization reserve power are considered for fuzzy multi-criteria function. To obtain an optimal solution for generator maintenance scheduling under fuzzy environment, fuzzy multi-criteria integer programming is used. In the maintenance scheduling, a characteristic feature of the presented approach is that the crisp constraints with uncertainty can be taken into account by using fuzzy set theory and so more flexible solution can be obtained. The effectiveness of the proposed approach is demonstrated by the simulation results.

  • PDF

Nonlinear Excitation Control Design of Generator Based on Multi-objective Feedback

  • Chen, Dengyi;Li, Xiaocong;Liu, Song
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권6호
    • /
    • pp.2187-2195
    • /
    • 2018
  • In order to realize the multi-objective control of single-input multi-output nonlinear differential algebraic system (NDAS) and to improve the dynamic characteristics and static accuracy, a design method of nonlinear control with multi-objective feedback (NCMOF) is proposed, the principium of this method to arrange system poles, as well as its nature to coordinate dynamic characteristics and static accuracy of the system are analyzed in detail. Through NCMOF design method, the multi-objective control of the system is transformed into linear space, and then it is effectively controlled under the nonlinear feedback control law, the problem to balance all control objectives caused by less input and more output of the system thus is solved. Applying NCMOF design method to generator excitation system, the nonlinear excitation control law with terminal voltage, active power and rotor speed as objective outputs is designed. Simulation results show that NCMOF can not only improve the dynamic characteristics of generator, but also damp the mechanical oscillation of a generator in transient process. Moreover, NCMOF can control the terminal voltage of the generator to the setting value with no static error under typical disturbances.

다중 엔트로피를 기반으로 하는 새로운 결정 트리 생성기 MEC (MEC; A new decision tree generator based on multi-base entropy)

  • 전병환;김재희
    • 한국통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.423-431
    • /
    • 1997
  • A new decision tree generator MEC is proposed in this paper, which uses the difference of multi-base entropy as a consistent criterion for discretization and selection of attributes. To evaluate the performance of the proposed generator, it is compared to other generators which use criteria based on entropy and adopt different discretization styles. As an experimental result, it is shown that the proposed generator produces the most efficient classifiers, which have the least number of leaves at the same error rate, regardless of whether attribute values constituting the training set are discrete or continuous.

  • PDF

Comparison between Two 450 mm Multi-Electrode Models

  • 박기정;이윤성;유대호;이진원;장홍영
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.490-490
    • /
    • 2013
  • In semiconductor industry, it is expected that plasma process which use 450 mm source will be used at next generation. However, main obstacle of the large area plasma source is plasma uniformity from it. When electrode is enlarged, field difference between center area and side area reduces the plasma uniformity [1-3]. Therefore we investigate multi-electrode which diminish this field difference.We designed two multi-electrode models. One has two segments and the other has five segments. Each multi-electrode model is connected with two power generator and two matchers. One generator and one matcher is connected with center electrode part. The other one generator and the other one matcher is connected with side electrode part. The ion density is measured at 29 points by using floating harmonic method [4-6]. After measuring the data of each multi-electrode model, we discuss the difference of profile between two models' data.

  • PDF

Flexible Maintenance Scheduling of Generation System by Multi-Probabilistic Reliability Criterion in Korea Power System

  • Park, Jeong-Je;Choi, Jae-Seok;Baek, Ung-Ki;Cha, Jun-Min;Lee, Kwang-Y.
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.8-15
    • /
    • 2010
  • A new technique using a search method which is based on fuzzy multi-criteria function is proposed for GMS(generator maintenance scheduling) in order to consider multi-objective function. Not only minimization of probabilistic production cost but also maximization of system reliability level are considered for fuzzy multi-criteria function. To obtain an optimal solution for generator maintenance scheduling under fuzzy environment, fuzzy multi-criteria relaxation method(fuzzy search method) is used. The practicality and effectiveness of the proposed approach are demonstrated by simulation studies for a real size power system model in Korea in 2010.

태양전지 최대전력 발생을 위한 다 평면 반사경 태양추적시스템 개발 (Development of Multi-flat Reflector Sun Tracking System for Sun Photocell Maximum Power Generation)

  • 이광신;이현석;유석주;박왈서
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.67-72
    • /
    • 2011
  • Recently, photovoltaic generator system is widely extended by energy policy of the government. Add to this, for high efficiency of power generation per natural light unit area is needed to sun tracking system. And it is needed to condensed light generator for reducer of equipment expense. As method of solving this problem, this paper is developed multi-flat reflector sun tracking system for sun photocell maximum power generation. The system is consisted of multi-flat reflector and two axes machinery and sun location perceiver and AVR controller. GaAs 3J cell generated 6.75 times power more than silicon cell by times condensing light system. As a result, condensing light system of multi-flat reflector generated maximum power and showed reducing costs to photovoltaic generator.

Design of a Fully Reconfigurable Multi-Constellation and Multi-Frequency GNSS Signal Generator

  • ByungHyun Choi;Young-Jin Song;Subin Lee;Jong-Hoon Won
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제12권3호
    • /
    • pp.295-306
    • /
    • 2023
  • This paper presents a multi-frequency and multi-constellation Global Navigation Satellite System (GNSS) signal generator that simulates intermediate frequency level digital signal samples for testing GNSS receivers. GNSS signal generators are ideally suited for testing the performance of GNSS receivers and algorithms under development in the laboratory for specific user locations and environments. The proposed GNSS signal generator features a fully-reconfigurable structure with the ability to adjust signal parameters, which is beneficial to generate desired signal characteristics for multiple scenarios including multi-constellation and frequencies. Successful signal acquisition, tracking, and navigation are demonstrated on a verified Software Defined Radio (SDR) in this study. This work has implications for future studies and advances the research and development of new GNSS signals.