• Title/Summary/Keyword: multi-electrode

Search Result 413, Processing Time 0.029 seconds

Probing of Steel Bar Location inside Concrete using Multi-electrode Array (다전극 배열을 이용한 콘크리트 매립 철근의 위치탐사)

  • 이형우;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.663-666
    • /
    • 2003
  • Using numerical analysis modeling of Multi-electrode Array that could be applied to the corrosion state measurement of a reinforcing steel bar in concrete, the steel bar location inside concrete can be probed by the investigation of the change of the measured impedance from concrete surface determined by the electrical impedance of interface between the steel bar and concrete, the electrical resistivity of concrete, the array of electrodes and the relative location and diameter of the steel bar.

  • PDF

A Study on the Characteristics of Circular Piezoelectric Transformner which has Multi-layered Crescent-Shaped Input Electrode (적층형 Crescent-Shaped Input Type 원형 압전변압기의 특성)

  • Jeong, Seong-Su;Park, Tae-Gone
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.223-224
    • /
    • 2006
  • This paper present a new disk-type piezoelectric transformer. The input side of the transformer has a crescent-shaped electrode and the output side has a focused poling direction. This transformer has multi-layered structure. The piezoelectric transformers operated m each transformer's resonance vibration mode. The electrodes and poling directions on commercialy available piezoelectric ceramic disks were designed so that the planar or shear mode coupling factor ($k_p,\;k_{15}$) becomes effective rather than the transverse mode coupling factor ($k_{31}$). The Resonance frequency is 65.22[kHz] and maximum voltage step-up ratio is 149. Multi-layered transformer has better efficiency and step-up ratio than the single-layered transformer.

  • PDF

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

Computation of the Critical Lengths of the Vertical Grounding Electrode in Multi-Layered Soil Structures (다층 대지구조에서 수직 접지전극의 임계길이 산정)

  • Kim, Ki-Bok;Joe, Jeong-Hyeon;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The grounding impedance is not lowered by expanding the dimension of the grounding electrode, and the length of grounding electrode which shows the minimum value of the grounding impedance for each condition of frequency and soil characteristics is existent, and it is defined as Critical Length. In this paper, a new distributed parameter circuit model considering the condition of the multi-layered soil structures was proposed, and the grounding impedance and critical length of the vertical grounding electrode were analyzed by using the newly proposed simulation model and the MATLAB program. As a consequence, it was found that the effect of the soil structure on the frequency-dependent grounding impedance and critical length of the vertical grounding electrode is significant. It is desirable to consider the soil structure in optimal design of the grounding system.

Development of Multi-rod Type Ag-AgCl Electrodes for an Underwater Electric Field Sensor (수중 전기장 센서용 다중 막대형 은-염화은 전극 개발)

  • Lee, Sangkyu;Yang, Chang-Seob;Chung, Hyun-Ju
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.45-50
    • /
    • 2022
  • Multi-rod type Ag-AgCl electrodes have been developed for use in underwater electric field sensors. The developed cylindrical electrode had a diameter of 50 mm and a height of 130 mm. The electrode had five Ag-AgCl rods with a diameter of 2 mm and a height of 80 mm to enlarge the reaction surface area. Each Ag-AgCl rod was fabricated under the same conditions as the usual anodizing method in an electrolyte. The two developed electrodes were placed in the center of a 500-mm long, 400-mm wide, and 300-mm high acrylic tank filled with artificial seawater, at an interval of 100 mm, to evaluate their characteristics as uniaxial underwater electric field sensors. The underwater external electric field was generated using titanium plate electrodes installed at both ends of the tank. The noise level at 1 Hz of the developed electrode was approximately 3.7 nV/√Hz. The reception of the underwater electric field signal using the developed electrode was linear, within an error of approximately 0.6 %, in the range of 1-10000 ㎶/m at 1 Hz. In addition, its frequency response was flat within an error of 1.1 % in the range of 1-1000 Hz at 10000 ㎶/m.

Development of Multi-Array Electrode and Programmable Multi-channel Electrical Stimulator for Firing Trigger Point of Myofascial Pain Syndrome (근막통증증후군의 통증유발점 치료를 위한 멀티어레이 전극과 프로그램 가능한 다채널 전기자극기 개발)

  • Kim, SooHong;Kim, SooSung;Jeon, GyeRok
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.221-227
    • /
    • 2015
  • In this study, Multi-Array Electrodes (MAE) and Programmable Multi-channel Electrical Stimulator (PMES) were implemented for firing Trigger Points (TPs) of the patient with Myofascial Pain Syndrome (MPS). MAE has 25 Ag/AgCl electrodes arranged in the form of array ($5{\times}5$) fabricated with flexible pad, which are applicable to be easy-attached to curved specific region of the human body. PMES consisted of 25 channels. Each channel was to generate various electric stimulus patterns (ESPs) by changing the mono-phasic or bi-phasic of ESP, On/Off duration of ESP, the interval between ESP, and amplitude of ESP. PMES hardware was composed of Host PC, Stimulation Pattern Editing Program (SPEP), and Multi-channel Electrical Stimulator (MES). Experiments were performed using MAE and PMES as the following. First experiment was performed to evaluate the function for each channel of Sub- Micro Controller Unit (SMCU) in MES. Second experiment was conducted on whether ESP applied from each channel of SMCU in PMES was focused to the electrode set to the ground, after applying ESP being output from each channel of SMCU in PMES to MAE.

Electrode Shape Optimization of Piezo Sensors Using Genetic Algorithm (유전 알고리듬을 이용한 압전센서의 전극형상 최적화)

  • Lee Ki-Moon;Park Hyun-Chul;Park Chul-Hue
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.6 s.249
    • /
    • pp.698-704
    • /
    • 2006
  • This paper presents an electrode shape design method for the multi-mode sensors that could deteict the selected structural multiple modes. The structure used for this study is an isotropic cantilever beam type with a PVDF (polyvinylidene fluoride) which is bonded onto the structure as a sensor. The shape optimization problem is solved by using Genetic Algorithm (GA) with an appropriate objective function. The performance of analytical optimal shape sensor is compared with that of experimental work. The results show that the, obtained electrode shape sensors have good performance to detect the multiple vibration modes simultaneously.

The Characteristics of Multi Gap Type Ozonizer (다중 간극형 오존발생장치의 특성)

  • 김금영;문경수;전병준;박용권;김상구;김영훈;김영길;이광식
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.145-148
    • /
    • 1999
  • In this paper, multi gap type ozonizer(MGO) has been designed and manufactured. The ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode) of cylinder shape. This paper describes the following two characteristics: $\circled1$ The characteristics of discharge with variation of output voltage of AC H.V source, flux of oxygen supplied gas and discharge voltage. $\circled2$ The characteristics of ozone generation by varying flux and discharge power.

  • PDF

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF