• Title/Summary/Keyword: multi-discharge

Search Result 360, Processing Time 0.089 seconds

Low-Pressure Mercury-Free Fluorescent Lamp for General Lighting

  • Jinno, Masafumi;Lee, Jong-Chan;Motomural, Hideki;Aono, Masaharu;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper we report on development of our original mercury-less fluorescent lamps for general lighting. These new-type lamps have multi-pairs of electrodes to maintain multi-discharge paths and to keep positive column diffused state. The omission characteristics oft the lamps were investigated. These discharge lamps were operated by pulsed discharge. By using multi-pairs of electrodes for xenon pulsed discharge fluorescent lamps, higher intensity of luminance was obtained than the conventional type of lamps using single pair of electrodes. Recently this type of lamp achieved over $9000\;cd/m^2$ and 50 lm/W.

  • PDF

Discharge and Ozone Characteristics of Multi Discharge Type Ozonizer (다중방전형 오존발생기의 방전 및 오존생성특성)

  • Chun, Byung-Joon;Mun, Kyung-Su;Song, Hyun-Gik;Kim, Keum-Yeung;Lee, Kwang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1090-1092
    • /
    • 1999
  • In this paper, multi discharge type ozonizer has been designed and manufactured. The of ozonizer is equipped with three electrodes(central electrode of screw shape, internal electrode and external electrode). This paper describes the following two characteristics: (1) The characteristics of discharge with variation of output voltage of AC H.V source, flow rate of oxygen supplied gas and discharge voltage. (2) The characteristics of ozone generation by varying flow rate and discharge power.

  • PDF

The Characteristics of High Ozone Concentration.Yield Multi-discharge Type Ozonizer for Water Environment Improvement (수질환경개선용 고농도·고수율 다중방전형 오존발생기의 특성)

  • ;宋炫直
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.2
    • /
    • pp.203-203
    • /
    • 1999
  • In this paper, high concentration·yield multi-discharge type ozonizer( MDO ) of new discharge type using superposed silent discharge was designed and manufactured. MDO can be consisted with 3 kind of superposed silent discharge type ozonizer( SDO ) in accordance with power supply method that supplying power, which has 180[°] phase difference, to 3 electrodes and double gap. At the moment discharge characteristics and ozone generation characteristics of each SDO were investigated in accordance with quantify of supplied gas, the number of SDO, and the shapes of each SDO. In result ozone generation characteristics of 17185[ppm] and 783[g/kWh] were obtained, and whorl ozone of 17185[ppm] was in contact with dyeing water waste decolonization characteristics was excellent, so it confirmed that MDO could be used as water environment improvement facility.

Analysis of multi-layered Surface with Glow Discharge-Mass Spectrometry (글로우방전 질량분석법을 이용한 다층박막의 표면 분석)

  • Pak, Yong-Nam;Lee, Gae-Ho;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.10 no.5
    • /
    • pp.357-361
    • /
    • 1997
  • A Griemm type Glow Discharge cell is attached to a commercial quadrapole based ICP-MS and used for the analysis of surface analysis. By employing 2.0mm diameter, mode and proper experimental conditions, several layers of few ${\mu}m$ thickness are analysed within 30 minutes. Multi-layers of Cu-Ni, Fe-Ni are analyzed with the resolution of 10nm by GDMS. Proper experimental conditions make a flat bottom crater shape and good resolution for multi-layer depth profile study.

  • PDF

Self-Discharge Effects on Multi-Lamps Backlight Driven by a High Speed Switching Inverter

  • Kwon, Nam-O;Kim, Young-M;Kim, Sung-J;Cho, Tae-Sung;Cho, Guang-Sup;Kim, Bong-Soo;Kang, June-G
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.539-540
    • /
    • 2002
  • A self-discharge in multi-EEFLs and CCFLs has been found to provide a high luminance and efficiency. With a fast rising and falling times of $2{mu}s$, and the peak voltage over 1.6KV, the self-discharge occurs in EEFLs and CCFLs driven by a full bridge switching inverter. Particularly in CCFLs connected with a typical value of ballast capacitance, a self-discharge follows by the main discharge when the voltage falls to the ground.

  • PDF

Discrimination of Multi-PD sources using wavelet 2D compression for T-F distribution of PD pulse waveform (부분방전 펄스파형의 시간-주파수분포의 웨이블렛 2D 압축기술을 이용한 복합부분방전원의 식별)

  • Lee, K.W.;Kim, M.Y.;Baik, K.S.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1784-1786
    • /
    • 2004
  • PD(Partial Discharge) signal emitted from PD sources has their intrinsic features in the region of time and frequency. STFT(Short Time Fourier Transform) shows time-frequency distribution at the same time. 2-Dimensional matrices(33${\times}$77) from STFT for PD pulse signals are a good feature vectors and can be decreased in dimension by wavelet 2D data compression technique. Decreased feature vectors(13${\times}$24) were used as inputs of Back-propagation ANN(Artificial Neural Network) for discrimination of Multi-PD sources(air discharge sources(3), surface discharge(1)). They are a good feature vectors for discriminating Multi-PD sources.

  • PDF

HID Ballast using Soft Switching Multi Level Inverter (Soft Switching Multi Level Inverter를 이용한 HID용 Ballast)

  • Lee Jang-Sun;Kim Yoon-Ho;Kim Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.628-634
    • /
    • 2004
  • The soft switching is applied to the multi-level inverter to enhance the characteristics of HID(High Intensity Discharge) Ballast in headlight of vehicle. The electrical properties are investigated. The available modeling of the ballast in steady-state is calculated using mathematical method and the result is used in analyzing the power characteristics and design of the system. Finally the designed system md modeling is confirmed by the experiment.

AC PDP(Plasma Display Panel)의 방전 특성 해석

  • 황기웅;정희섭;서정현
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1997.07a
    • /
    • pp.173-176
    • /
    • 1997
  • A numerical analysis of the micro-discharge in an AC pplasma dispplay cell has been made using time-deppendent, 2-dimensional multi-fluid equations to understand the discharge pphysics of He-Xe discharge. The time deppendent distribution of the electron tempperature, densities of electrons, various ions and excited sppecies, and the effects fo the wall charge accumulated on the dielectric surface are obtained and comppared with the results of direct observation of time deppendent behavior of VUV and visible sppectra from single discharge cell observed using a gated, image intensified CCD to elucidate the discharge physics.

  • PDF

Inactivation of Sewage Microorganisms using Multi-Plasma Process (멀티 플라즈마 공정을 이용한 하수 미생물의 불활성화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.23 no.5
    • /
    • pp.985-993
    • /
    • 2014
  • For the field application of dielectric barrier discharge plasma reactor, a multi-plasma reactor was investigated for the inactivation of microorganisms in sewage. We also considered the possibility of degradation of non-biodegradable matter ($UV_{254}$) and total organic carbon (TOC) in sewage. The multi-plasma reactor in this study was divided into high voltage neon transformers, gas supply unit and three plasma modules (consist of discharge, ground electrode and quartz dielectric tube). The experimental results showed that the inactivation of microorganisms with treated water type ranked in the following order: distilled water > synthetic sewage effluent >> real sewage effluent. The dissolved various components in the real sewage effluent highly influenced the performance of the inactivation of microorganisms. After continuous plasma treatment for 10 min at 180 V, residual microorganisms appeared below 2 log and $UV_{254}$ absorbance (showing a non-biodegradable substance in water) and TOC removal rate were 27.5% and 8.5%, respectively. Therefore, when the sewage effluent is treated with plasma, it can be expected the inactivation of microorganisms and additional improvement of water quality. It was observed that the $NH_4{^+}$-N and $PO{_4}^{3-}$-P concentrations of sewage was kept at the constant plasma discharging for 30 min. On the other hand, $NO_3{^-}$-N concentration was increased with proceeding of the plasma discharge.

Synthesis and Characterization of TiO2, Cu2O and Al2O3 Aerosol Nanoparticles Produced by the Multi-Spark Discharge Generator

  • Efimov, Alexey;Lizunova, Anna;Sukharev, Valentin;Ivanov, Victor
    • Korean Journal of Materials Research
    • /
    • v.26 no.3
    • /
    • pp.123-129
    • /
    • 2016
  • The morphology, crystal structure and size of aerosol nanoparticles generated by erosion of electrodes made of different materials (titanium, copper and aluminum) in a multi-spark discharge generator were investigated. The aerosol nanoparticle synthesis was carried out in air atmosphere at a capacitor stored energy of 6 J, a repetition rate of discharge of 0.5 Hz and a gas flow velocity of 5.4 m/s. The aerosol nanoparticles were generated in the form of oxides and had various morphologies: agglomerates of primary particles of $TiO_2$ and $Al_2O_3$ or aggregates of primary particles of $Cu_2O$. The average size of the primary nanoparticles ranged between 6.3 and 7.4 nm for the three substances studied. The average size of the agglomerates and aggregates varied in a wide interval from 24.6 nm for $Cu_2O$ to 46.1 nm for $Al_2O_3$.