• Title/Summary/Keyword: multi-cable

Search Result 281, Processing Time 0.026 seconds

Static behaviour of lying multi-stud connectors in cable-pylon anchorage zone

  • Lin, Zhaofei;Liu, Yuqing;He, Jun
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1369-1389
    • /
    • 2015
  • In order to investigate the behaviour of lying multi-stud connectors in cable-pylon anchorage zone, twenty-four push-out tests are carried out with different stud numbers and diameters. The effect of concrete block width and tensile force on shear strength is investigated using the developed and verified finite element model. The results show that the shear strength of the lying multi-stud connectors is reduced in comparison with the lying single-stud connector. The reduction increases with the increasing of the number of studs in the vertical direction. The influence of the stud number on the strength reduction of the lying multi-stud connectors is decreased under combined shear and tension loads compared with under pure shear. Yet, due to multi-stud effect, they still can't be ignored. The concrete block width has a non-negligible effect on the shear strength of the lying multi-stud connectors and therefore should be chosen properly when designing push-out specimens. No obvious difference is observed between the strength reductions of the studs with 22 mm and 25 mm diameters. The shear strengths obtained from the tests are compared with those predicted by AASHTO LRFD and Eurocode 4. Eurocode 4 generally gives conservative predictions of the shear strength, while AASHTO LRFD overestimates the shear strength. In addition, the lying multi-stud connectors with the diameters of 22 m and 25 mm both exhibit adequate ductility according to Eurocode 4. An expression of load-slip curve is proposed for the lying multi-stud connectors and shows good agreement with the test results.

Design and Implementation the USB Multi-signal Transmission System (USB 다중 신호 전송 시스템 설계 및 구현)

  • Chae, Jung-Sik;Kim, Jong-Moon;Kim, Chang-Su;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.623-625
    • /
    • 2013
  • This signal can be distributed using a single USB cable, computer, video, audio, USB, LAN, one USB multi-signal transmission system was designed and implemented. USB multi-signal transmission was implemented in order to convert a single DVI, audio, and multiple USB, LAN, USB signal converter modules. This USB DVI port supports up to 1920 * 1090 resolution. USB multi-signal transmission system by sending multiple signals into a single cable installation costs of the various cable and using the replication feature of the screen, will provide schools and institutes, etc., providing the convenience of the river, and the scalability of computer peripheral ports.

  • PDF

Analysis of Electromagnetic Pulse Coupling to Twisted Cable Using Chain Matrix (Chain Matrix를 이용한 Twisted Cable의 EMP(Electromagnetic Pulse) 결합 해석)

  • Cho, Jea-Hoon;Lee, Jin-Ho;Kim, Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.7
    • /
    • pp.734-743
    • /
    • 2010
  • In this paper, we analyzed the EMP coupling for the nonuniform transmission lines, such as twisted cables, using the chain matrix algorithm and the multi-conductor analysis. The BLT method is widely used for the EMP coupling analysis of the transmission line, however, it is difficult to apply to the nonuniform transmission lines. In order to analyze the EMP coupling of nonuniform transmission lines, the whole nonuniform transmission line is divided into incremental uniform line sections of the finite numbers, and the coupling in each small sections is now summed up to get the EMP coupling effect of the entire nonuniform transmission line. To verify the proposed EMP coupling analysis method, the result of the EMP coupling simulation is compared with the solution of BLT equations for a uniform transmission line case. The proposed method is applied to the twisted cable over ground in case of being illuminated by the HEMP in order to analyze the EMP coupling.

DC Performance of $Nb_3$Sn Cable Joints with multi-interfaces (다수의 접합경계를 갖는 $Nb_3$Sn 케이블 접합부의 직류 저항 특성)

  • 이호진;김기백;연제욱;홍계원;김기만
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.2
    • /
    • pp.170-176
    • /
    • 2000
  • The joints with multi-interfaces was expected to have low DC resistance compared with those with single interface. The small size joint specimens joined with Nb3Sn sub-cables were fabricated to investi-gate the DC performance in the range of 0 to 600A transport current without external magnetic field. The joints with multi-interfaces have a few n-Ohm resistance, which is much lower than that of single lap joint. Because the interfaces between sub-cables of multi-interfaced joint are more complicated than those of single-interfaced joint, the soldering condition between sub-cables is very effective on the joint DC resistance.

  • PDF

Wireless structural health monitoring of stay cables under two consecutive typhoons

  • Kim, Jeong-Tae;Huynh, Thanh-Canh;Lee, So-Young
    • Structural Monitoring and Maintenance
    • /
    • v.1 no.1
    • /
    • pp.47-67
    • /
    • 2014
  • This study has been motivated to examine the performance of a wireless sensor system under the typhoons as well as to analyze the effect of the typhoons on the bridge's vibration responses and the variation of cable forces. During the long-term field experiment on a real cable-stayed bridge in years 2011-2012, the bridge had experienced two consecutive typhoons, Bolaven and Tembin, and the wireless sensor system had recorded data of wind speeds and vibration responses from a few survived sensor nodes. In this paper, the wireless structural health monitoring of stay cables under the two consecutive typhoons is presented. Firstly, the wireless monitoring system for cable-stayed bridge is described. Multi-scale vibration sensor nodes are utilized to measure both acceleration and PZT dynamic strain from stay cables. Also, cable forces are estimated by a tension force monitoring software based on vibration properties. Secondly, the cable-stayed bridge with the wireless monitoring system is described and its wireless monitoring capacities for deck and cables are evaluated. Finally, the structural health monitoring of stay cables under the attack of the two typhoons is described. Wind-induced deck vibration, cable vibration and cable force variation are examined based on the field measurements in the cable-stayed bridge under the two consecutive typhoons.

Field application of elasto-magnetic stress sensors for monitoring of cable tension force in cable-stayed bridges

  • Yim, Jinsuk;Wang, Ming L.;Shin, Sung Woo;Yun, Chung-Bang;Jung, Hyung-Jo;Kim, Jeong-Tae;Eem, Seung-Hyun
    • Smart Structures and Systems
    • /
    • v.12 no.3_4
    • /
    • pp.465-482
    • /
    • 2013
  • Recently, a novel stress sensor, which utilizes the elasto-magnetic (EM) effect of ferromagnetic materials, has been developed to measure stress in steel cables and wires. In this study, the effectiveness of this EM based stress sensors for monitoring of the cable tension force of a real scale cable-stayed bridge was investigated. Two EM stress sensors were installed on two selected multi-strand cables in Hwa-Myung Bridge, Busan, South Korea. Conventional lift-off test was conducted to obtain reference cable tension forces of two test cables. The reference forces were used to calibrate and validate cable tension force measurements from the EM sensors. Tension force variations of two test cables during the second tensioning work on Hwa-Myung Bridge were monitored using the EM sensors. Numerical simulations were conducted to compare and verify the monitoring results. Based on the results, the effectiveness of EM sensors for accurate field monitoring of the cable tension force of cable-stayed bridge is discussed.

Modal Parameter Extraction Using a Digital Camera (디지털 카메라를 이용한 구조물의 동특성 추출)

  • Kim, Byeong-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.61-68
    • /
    • 2008
  • A set of modal parameters of a stay-cable have been extracted from a moving picture captured by a digital camera supported by shaking hands. It is hard to identify the center of targets attached on the cable surface from the blurred cable motion image, because of the high speed motion of cable, low sampling frequency of camera, and the shaking effect of camera. This study proposes a multi-template matching algorithm to resolve such difficulties. In addition, a sensitivity-based system identification algorithm is introduced to extract the natural frequencies and damping ratios from the ambient cable vibration data. Three sets of vibration tests are conducted to examine the validity of the proposed algorithms. The results show that the proposed technique is pretty feasible for extracting modal parameters from the severely shaking motion pictures.

  • PDF

Performance and Design of Cable Termination for 154kV Class (154kV 케이블 콘넥터의 설계와 특성 평가 연구)

  • Cho, Han-Goo;Kim, Kyang-Young;Lee, Cheol-Ho;Lee, Yong-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.112-112
    • /
    • 2010
  • The purpose of development is to localize a connector for connection of cable and GIS for underground transmission system. The cable connector for GIS provides electrical insulation of GIS housing part and makes connection of ultra high voltage electrical apparatus and power cable by controlling electrical stress between electrodes of power cable termination. Generally Korean switchgear makers are using a connector for GIS made by foreign companies. We manufactured sample by best structure design of great capacity conductor connecting part and then modified the design by analysis of shape and section. We completed the suitable sample for current cycling test condition of conductor connecting part sample and ensured surge characteristics of line by short-time current test.

  • PDF

A Study on Heat-Flux Evaluation for Cable Fire Including Diagnostic Methodology for Degradation in Nuclear Power Plants (원전 케이블 화재 열속평가 및 열화 진단방법에 관한 연구)

  • Lim, Hyuk-Soon;Kim, Doo-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.2
    • /
    • pp.20-25
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments. The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a multi-core cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the characteristic of cable fire is investigated and the heat-flux evaluation for cable fire is studied. Moreover, a diagnostic methodology for degraded cable in nuclear power plants is presented.

Insulation Characteristics of the Model Cable for 22.9 kV Class HTS Power Cable

  • Kim, Hae-Jong;Seong, Ki-Chul;Cho, Jeon-Wook;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.542-543
    • /
    • 2005
  • In this paper, describes the fabrication and dielectric insulation characteristics experimental results of the model cable for the 22.9kV class HTS power cable. The model cable were tested with partial discharge(PD), AC and impulse withstand voltage in liquid nitrogen($LN_2$) and liquid nitrogen pressure. In these test results, PD inception stress and AC, impulse breakdown strength increase as the pressure of the liquid nitrogen increases.

  • PDF