• Title/Summary/Keyword: multi-cable

Search Result 281, Processing Time 0.022 seconds

Local Fault Detection Technique for Steel Cable using Multi-Channel Magnetic Flux Leakage Sensor (다채널 자속누설 센서를 이용한 강케이블의 국부 단면손상 검색)

  • Park, Seunghee;Kim, Ju-Won;Lee, Changgil;Lee, Jongjae;Gil, Heung-Bae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.287-292
    • /
    • 2012
  • In this study, Multi-Channel Magnetic Flux Leakage(MFL) sensor - based inspection system was applied to monitor the condition of cables. This inspection system measures magnetic flux to detect the local faults(LF) of steel cable. To verify the feasibility of the proposed damage detection technique, an 8-channel MFL sensor head prototype was designed and fabricated. A steel cable bunch specimen with several types of damage was fabricated and scanned by the MFL sensor head to measure the magnetic flux density of the specimen. To interpret the condition of the steel cable, magnetic flux signals were used to determine the locations of the flaws and the level of damage. Measured signals from the damaged specimen were compared with thresholds set for objective decision making. In addition, the magnetic flux density values measured from every channel were summed to focus on the detection of axial location. And, sum of flux density were displayed with threshold. Finally, the results were compared with information on actual inflicted damages to confirm the accuracy and effectiveness of the proposed cable monitoring method.

Ultrasonic guided wave approach incorporating SAFE for detecting wire breakage in bridge cable

  • Zhang, Pengfei;Tang, Zhifeng;Duan, Yuanfeng;Yun, Chung Bang;Lv, Fuzai
    • Smart Structures and Systems
    • /
    • v.22 no.4
    • /
    • pp.481-493
    • /
    • 2018
  • Ultrasonic guided waves have attracted increasing attention for non-destructive testing (NDT) and structural health monitoring (SHM) of bridge cables. They offer advantages like single measurement, wide coverage of acoustical field, and long-range propagation capability. To design defect detection systems, it is essential to understand how guided waves propagate in cables and how to select the optimal excitation frequency and mode. However, certain cable characteristics such as multiple wires, anchorage, and polyethylene (PE) sheath increase the complexity in analyzing the guided wave propagation. In this study, guided wave modes for multi-wire bridge cables are identified by using a semi-analytical finite element (SAFE) technique to obtain relevant dispersion curves. Numerical results indicated that the number of guided wave modes increases, the length of the flat region with a low frequency of L(0,1) mode becomes shorter, and the cutoff frequency for high order longitudinal wave modes becomes lower, as the number of steel wires in a cable increases. These findings were used in design of transducers for defect detection and selection of the optimal wave mode and frequency for subsequent experiments. A magnetostrictive transducer system was used to excite and detect the guided waves. The applicability of the proposed approach for detecting and locating wire breakages was demonstrated for a cable with 37 wires. The present ultrasonic guided wave method has been found to be very responsive to the number of brokenwires and is thus capable of detecting defects with varying sizes.

A Study On The Bending Characteristics of Ribbon Cable Unit (리본광케이블 유니트의 구부림 특성 연구)

  • 이병철;이영탁;김미경
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.4
    • /
    • pp.379-384
    • /
    • 1995
  • In order to construct B-ISDN, it is inevitable to introduce optical fiber of low loss and wide bandwidth. Coincidently, high count optical fiber cable is solely important to form optical subscriber network. The best structure of high count optical fiber cable to achieve multi-splicing as well as high density at the same time is the one of taking optical ribbon as a unit of accomodation. However, since optical ribbon has its own width. optical loss due to length difference during the bending of ribbon cable unit occurs in relatively easy way. Therefore, care should be taken during its manufacturing and storage. In t\1::; paper, strain, bending radius and lateral pressure of each fiber in ribbon due to the bending of ribbon cable unit are caculated theoretically. Hence, we have measured optical loss of each fiber as function of unit bending radius, when we bent the ribbon cable unit on the various reel. We found that the result accords well with the theoretical analysis. The result shows the importance to determine proper radius of reel used in ribbon cable manufacturing and storage. orage.

  • PDF

Pitch Calculation of 4-layer HTS Power Transmission Cable far Balanced Sharing Current

  • Joo, Jin-Hong;Kim, Seog-Whan;Jeonwook Cho;Bae, Joon-Han;Kim, Hae-Jong;Seong, Ki-Chul;Hong, Jung-Pyo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.35-39
    • /
    • 2003
  • A typical HTS power transmission cable has multi-layer conductor structure to increase the current capacity. The tapes of the innermost layer are wound on a round former, and adjacent tapes of another layer are separated by a thin insulating film. However, usually the current is not evenly distributed among the layers because of inductance difference of each layer, and the inductance is provided by the winding pitch of each layer's tape. Consequently n method to make the current distribution more uniform is a adjusting the tape winding pitch, hence reduce the AC loss. This paper describes a current distribution by adjusting a tape winding pitch of each layer. Also, this paper shows recommendations for future cable conductor prototypes.

Development of Fault Detection and Noise Cancellation Algorithm Using Wavelet Transform on Underground Power Cable Systems (웨이블렛을 이용한 지중송전계통 고장검출 및 노이즈 제거 알고리즘 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.7
    • /
    • pp.1191-1198
    • /
    • 2007
  • In this paper, the fault detection and noise cancellation algorithm based on wavelet transform was developed to locate the fault more accurately. Specially, noise cancellation algorithm was based on the correlation of wavelet coefficients at multi-scales. Fault detection, classification and location algorithm were tested by EMTP simulation on real power cable system. From these results, the faults can be detected and located even in very difficult situations, such as at different inception angle and fault resistance.

Development of Fault Location Method Using SWT and Travelling Wave on Underground Power Cable Systems (SWT와 진행파를 이용한 지중송전계통 고장점 추정 기법 개발)

  • Jung, Chae-Kyun;Lee, Jong-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • The fault location algorithm based on stationary wavelet transform was developed to locate the fault point more accurately. The stationary wavelet transform(SWT) was introduced instead of conventional discrete wavelet transform(DWT) because SWT has redundancy properties which is more useful in noise signal processing. In previous paper, noise cancellation technique based on the correlation of wavelet coefficients at multi-scales was introduced, and the efficiency was also proved in full. In this paper, fault section discrimination and fault location algorithm using noise cancellation technique were tested by ATP simulation on real power cable systems. From these results, the fault can be located even in very difficult and complicated situations such as different inception angle and fault resistance.

Analysis of Current Distribution with Design Parameters of HTS Cable with Multi-Layer (다층 고온초전도 전력케이블의 설계 파라미터를 통한 전류분류 해석)

  • Lee, Jong-Hwa;Lim, Sung-Hun;Ko, Seok-Cheol;Park, Sig;Kang, Hyeong-Gon;Han, Byong-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.589-592
    • /
    • 2003
  • One important issue in the design and the optimization for conductor of a superconducting cable is the control of the current distribution flowing at each layers. In this paper, we calculated the self inductance of each layer and the mutual inductance between two layers from the magnetic field energy and investigated the effects of design parameters on the self and mutual inductances for 4-layer conductors with transport current distribution at each layer.

  • PDF

Experiment on Heat Loads Invaded into HTS Cable Cryostat under Cryogenic Insulation System (고온초전도 케이블용 cryostat의 단열조건에 대한 열침입량 측정)

  • Kim, Do-Hyeong;Jung, Won-Moog;Kim, Dong-Lak;Yang, Hyung-Suk;Cho, Seung-Yon;Hwang, Si-Dole
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1564-1569
    • /
    • 2004
  • Insulating a heat from the environment is the most important in cryogenic applications like HTS cable system. Vacuum and MLI(Multi-Layer Insulation) have been widely used to get highly efficient cryogenic insulation. In this study, experiment on annular cylinder regarded as basic model of HTS cable cryostat has been performed to measure the heat loads. To investigate the effectiveness of radiation shields in cryogenic insulation system, the experiments are carried out to various number of the shields. The measured values are compared with the results estimated theoretically. The heat loads invaded from the environment was determined by liquid nitrogen boil-off calorimetry.

  • PDF

Validation of Propagation Velocity through TDR Test in HVDC Submarine Cables (HVDC 해저케이블 TDR 시험을 통한 전파속도 검증)

  • Jung, Chae-Kyun;Park, Jun-Woo;Moon, Kyoung-Hee;Yang, Byeong-Mo;Kang, Ji-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.1888-1894
    • /
    • 2009
  • This paper performs TDR real test for measurement of propagation velocity on #1 Pole of HVDC submarine cable section between Jeju and Haenam, and then measured velocity is compared with theoretical value and velocity provided from manufacturer. The measured velocity is also validated from theoretical process based on CIGRE simplified approach. In this paper, the fault location algorithm using multi-scale correlation of SWT(stationary wavelet transform) and travelling wave is additionally proposed for HVDC submarine cable system, it includes fault signal filter for noise cancellation. Finally, the measured velocity is validated from proposed fault location algorithm test once more.

Nonlinear Time History Analysis of Long Span Cable-Stayed Bridge Considering Multi-Support Excitation (다지점 가진을 고려한 장경간 사장교의 비선형시간이력해석)

  • Kim, Jin-Il;Ha, Su-Bok;Sung, Dae-Jung;Kim, Mun-Young;Shin, Hyun-Mock
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.6
    • /
    • pp.655-662
    • /
    • 2011
  • For analyzing seismic performance of long-span bridge for multi-support excitation and preparing technically and efficiently for a variety of design demands, the new module on multiple excitation was built in a reliable non-linear analysis program(RCAHEST) by using Influence Line Method, and the study on structures was performed previously. Also, the result of the analysis through RCAHEST was compared and verified with commercial finite element analysis program SAP2000 by using the feature of Multi-Support Excitation. From these results, nonlinear time history analysis considering multi-support excitation was studied after designing FE model of Incheon cable-stayed bridge. It was proved that the maximum response of horizontal displacement decreased as the time delay was increasing at all nodes of bridge. And then the serviceability of analysis model was evaluated by performing ultimate analysis under changes in maximum acceleration of seismic load data.