• 제목/요약/키워드: multi-cable

검색결과 281건 처리시간 0.024초

Structural health monitoring data reconstruction of a concrete cable-stayed bridge based on wavelet multi-resolution analysis and support vector machine

  • Ye, X.W.;Su, Y.H.;Xi, P.S.;Liu, H.
    • Computers and Concrete
    • /
    • 제20권5호
    • /
    • pp.555-562
    • /
    • 2017
  • The accuracy and integrity of stress data acquired by bridge heath monitoring system is of significant importance for bridge safety assessment. However, the missing and abnormal data are inevitably existed in a realistic monitoring system. This paper presents a data reconstruction approach for bridge heath monitoring based on the wavelet multi-resolution analysis and support vector machine (SVM). The proposed method has been applied for data imputation based on the recorded data by the structural health monitoring (SHM) system instrumented on a prestressed concrete cable-stayed bridge. The effectiveness and accuracy of the proposed wavelet-based SVM prediction method is examined by comparing with the traditional autoregression moving average (ARMA) method and SVM prediction method without wavelet multi-resolution analysis in accordance with the prediction errors. The data reconstruction analysis based on 5-day and 1-day continuous stress history data with obvious preternatural signals is performed to examine the effect of sample size on the accuracy of data reconstruction. The results indicate that the proposed data reconstruction approach based on wavelet multi-resolution analysis and SVM is an effective tool for missing data imputation or preternatural signal replacement, which can serve as a solid foundation for the purpose of accurately evaluating the safety of bridge structures.

차폐층을 갖는 다층고온초전도 전력케이블의 전류분류 분석 (Analysis of Current Distribution of Multi-Layer HTSC Power Cable with a Shield Layer)

  • 이종화;임성훈;고석철;박충렬;한병성;황시돌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.535-538
    • /
    • 2004
  • Superconducting transmission power cable is one of interesting parts in power application using high temperature superconducting wire. One of important parameters in high-temperature superconduting (HTSC) cable design is transport current distribution because it is related with current transmission capacity and AC loss. In this paper, the transport current distribution at conducting layers was investigated through the analysis of the equivalent circuit for HTSC power cable with shield layer and compared with the case of without shield layer. The transport current distribution due to the pitch lenght was improved in the case of HTSC power cable with shield layer from the analysis.

  • PDF

누설자속센서를 탑재시킨 이동로봇을 이용한 사장교 케이블 비파괴검사 시스템의 현장 적용 (Field Application of a Cable NDT System for Cable-Stayed Bridge Using MFL Sensors Integrated Climbing Robot)

  • 김주원;최준성;이은찬;박승희
    • 비파괴검사학회지
    • /
    • 제34권1호
    • /
    • pp.60-67
    • /
    • 2014
  • 본 연구에서는 사장교의 핵심부재인 케이블 점검을 위한 자동화 검사 시스템을 개발하였다. 강자성체로 이뤄진 연속체 구조물인 케이블의 내외부 검사에 적합한 비파괴검사법으로는 선행연구를 통해 검증된 누설자속탐상법이 적용되었고, 홀센서와 영구자석을 이용하여 다채널의 누설자속 측정용 자기센서헤드를 제작하였다. 또한 케이블 검사의 자동화로 접근성을 높이기 위해 사장교 케이블을 따라 이동할 수 있는 바퀴굴림 방식의 케이블 등반 로봇을 설계 및 제작하였고, 로봇을 다양한 디바이스에서 모니터링 및 제어하기 위한 컨트롤 프로그램을 제작하였다. WLAN 방식의 무선통신기술을 적용하여 원격으로 계측 데이터 전송 및 로봇제어를 가능하게 하였다. 최종적으로 본 연구를 통해 개발된 세부 기술들이 연동된 누설자속탐상법 기반 케이블 이동형 진단 시스템을 이용하여 실제 운용중인 서해대교의 케이블을 대상으로 현장 시험을 수행함으로써 본 시스템의 현장 적용성을 검증해보았다.

HTS 케이블 냉각용 역브레이튼 사이클 극저온 냉동기 설계에 관한 연구 (Design of Reverse Brayton Cycle Cryocooler System for HTS Cable Cooling)

  • 박재홍;권용하;김영수;박성출
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.58-65
    • /
    • 2003
  • The high temperature superconductivity(HTS) cable must be cooled below the nitrogen liquefaction temperature to applicate the cable in power generation and transmi-ssion system under the superconducting state. To obtain superconducting state. a reliable cryocooler system is required. Structural and thermal design have been performed to design cryocooler system operated with reverse Brayton cycle using gas neon as refrigerant. This cryocooler system consists of compressor. recuperator. coldbox. control valves and has 1 kW cooling capacity. Heat loss calculation was conducted for the given cryocooler system by considering the conduction and radiation through the multi-layer insulation(MLI) and high vacuum. The results can be summarized as: conduction heat loss is 7 W in valves and access port and radiation heat loss is 18 W through the surface of cryocooler. The full design specifications were discussed and the results were applied to construct in house HTS cable cooling system.

초전도 전력 케이블에서의 stabilizer의 형태에 따른 와전류 손실 해석 (Analysis of eddy current loss in high-Tc superconducting power cables with respect to various structure of stabilizer)

  • 최석진;송명곤;이상진;심기덕;조전욱
    • Progress in Superconductivity
    • /
    • 제7권1호
    • /
    • pp.83-86
    • /
    • 2005
  • The High-Tc superconducting power cable consists of a multi-layer high-Tc superconducting cable core and a stabilizer which is used to bypass the current at fault time. Eddy current loss is generated in the stabilizer in normal operating condition and affects the whole system. In this paper, the eddy current losses are analyzed with respect to various structure of stabilizer by using opera-3d. Moreover, optimal conditions of the stabilizer are derived to minimize the eddy current losses from the analyzed results. The obtained results could be applied to the design and manufacture of the high-Tc superconducting power cable system.

  • PDF

Entropy-based optimal sensor networks for structural health monitoring of a cable-stayed bridge

  • Azarbayejani, M.;El-Osery, A.I.;Taha, M.M. Reda
    • Smart Structures and Systems
    • /
    • 제5권4호
    • /
    • pp.369-379
    • /
    • 2009
  • The sudden collapse of Interstate 35 Bridge in Minneapolis gave a wake-up call to US municipalities to re-evaluate aging bridges. In this situation, structural health monitoring (SHM) technology can provide the essential help needed for monitoring and maintaining the nation's infrastructure. Monitoring long span bridges such as cable-stayed bridges effectively requires the use of a large number of sensors. In this article, we introduce a probabilistic approach to identify optimal locations of sensors to enhance damage detection. Probability distribution functions are established using an artificial neural network trained using a priori knowledge of damage locations. The optimal number of sensors is identified using multi-objective optimization that simultaneously considers information entropy and sensor cost-objective functions. Luling Bridge, a cable-stayed bridge over the Mississippi River, is selected as a case study to demonstrate the efficiency of the proposed approach.

R&D trends of high current REBCO conductor

  • Oh, Sang-Soo
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제24권1호
    • /
    • pp.1-7
    • /
    • 2022
  • So far, large-scale scientific devices such as nuclear fusion tokamaks and high energy circular accelerators were constructed using high-current conductors made of metallic superconducting wires. Recently, as REBCO superconducting wires usable in high magnetic fields have been developed by several companies, researchesto apply high current cable type REBCO conductors to next-generation large superconducting magnets were also started. High critical currents of several kA or more in high magnetic fields have been successfully demonstrated on test samples of REBCO cable conductors by several research groups. In this review article, the main features and properties of the representative high current REBCO conductors such as CORC(Conductor On Round Core), TSTC(Twisted Stacked-Tape Cable) and RACC(Roebel-Assembled Coated Conductor), which are currently being developed at abroad are briefly introduced. Research activities of high-current density REBCO MHOS(Multi HTS layers on One Substrate) conductor at KERI, whose structure is different from other cable type REBCO conductors are also shortly introduced.

Space grid analysis method in modelling shear lag of cable-stayed bridge with corrugated steel webs

  • Ma, Ye;Ni, Ying-Sheng;Xu, Dong;Li, Jin-Kai
    • Steel and Composite Structures
    • /
    • 제24권5호
    • /
    • pp.549-559
    • /
    • 2017
  • As few multi-tower single-box multi-cell cable-stayed bridges with corrugated steel webs have been built, analysis is mostly achieved by combining single-girder model, beam grillage model and solid model in support of the design. However, such analysis methods usually suffer from major limitations in terms of the engineering applications: single-girder model fails to account for spatial effect such as shear lag effect of the box girder and the relevant effective girder width and eccentric load coefficient; owing to the approximation in the principle equivalence, the plane grillage model cannot accurately capture shear stress distribution and local stress state in both top and bottom flange of composite box girder; and solid model is difficult to be practically combined with the overall calculation. The usual effective width method fails to provide a uniform and accurate "effective length" (and the codes fail to provide a unified design approach at those circumstance) considering different shear lag effects resulting from dead load, prestress and cable tension in the construction. Therefore, a novel spatial grid model has been developed to account for shear lag effect. The theoretical principle of the proposed spatial grid model has been elaborated along with the relevant illustrations of modeling parameters of composite box girder with corrugated steel webs. Then typical transverse and longitudinal shear lag coefficient distribution pattern at the side-span and mid-span key cross sections have been analyzed and summarized to provide reference for similar bridges. The effectiveness and accuracy of spatial grid analysis methods has been finally validated through a practical cable-stayed bridge.

고정하중을 받는 다경간 현수교의 예비해석을 위한 케이블 부재의 초기평형상태 해석 (Initial Equilibrium State Analysis of Cable Members for Preliminary Analysis of Multi-span Suspension Bridge under Dead Load)

  • 최동호;나호성;권순길
    • 대한토목학회논문집
    • /
    • 제36권1호
    • /
    • pp.21-29
    • /
    • 2016
  • 본 연구에서는 고정하중을 받는 다경간 현수교의 예비해석을 위한 케이블 부재의 초기평형상태 해석방법을 제안한다. 본 연구에서 제안한 초기 평형상태 해석 알고리즘은 타 연구들에서 사용된 기존 방법들보다 간편하고 실용적이며, 3경간 현수교 및 다경간 현수교에 적용 가능하다. 제안방법의 타당성을 검증하기 위해, 3경간 현수교 예제모델과 4경간 현수교인 국내의 새천년대교 및 중국의 Yingwuzhou Bridge 모델을 사용하여 초기평형상태 해석을 수행하였다. 검증 결과, 본 연구에서 제안한 초기평형상태 해석방법에 의한 결과가 3경간 예제모델의 선행 연구결과 및 새천년대교의 설계값과 잘 일치하는 경향을 나타내었으며, 제안 방법은 Yingwuzhou Bridge에 대한 초기형상을 잘 유지하는 초기값들을 도출하였다.