• Title/Summary/Keyword: multi-axial testing system

Search Result 11, Processing Time 0.023 seconds

The Establishment of Multi Axial Fatigue Testing System for Rail Fastening Component/System (레일체결장치 다축피로시험장비 구축)

  • Kim, Eun;Kim, Tae-Wook;Park, Ok-Jung
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1156-1162
    • /
    • 2007
  • This paper describes overall background and current status of the establishment of multi axial fatigue testing system for rail fastening component/system. With above viewpoint, general features of rail fastening system, domestic/international testing standards, main features of testing system, application plan, etc. are summarized.

  • PDF

The multi-axial testing system for earthquake engineering researches

  • Lin, Te-Hung;Chen, Pei-Ching;Lin, Ker-Chun
    • Earthquakes and Structures
    • /
    • v.13 no.2
    • /
    • pp.165-176
    • /
    • 2017
  • Multi-Axial Testing System (MATS) is a 6-DOF loading system located at National Center for Research on Earthquake Engineering (NCREE) in Taiwan for advanced seismic testing of structural components or sub-assemblages. MATS was designed and constructed for a large variety of structural testing, especially for the specimens that require to be subjected to vertical and longitudinal loading simultaneously, such as reinforced concrete columns and lead rubber bearings. Functionally, MATS consists of a high strength self-reacting frame, a rigid platen, and a large number of servo-hydraulic actuators. The high strength self-reacting frame is composed of two post-tensioned A-shape reinforced concrete frames interconnected by a steel-and-concrete composite cross beam and a reinforced concrete reacting base. The specimen can be anchored between the top cross beam and the bottom rigid platen within a 5-meter high and 3.25-meter wide clear space. In addition to the longitudinal horizontal actuators that can be installed for various configurations, a total number of 13 servo-hydraulic actuators are connected to the rigid platen. Degree-of-freedom control of the rigid platen can be achieved by driving these actuators commanded by a digital controller. The specification and information of MATS in detail are described in this paper, providing the users with a technical point of view on the design, application, and limitation of MATS. Finally, future potential application employing advanced experimental technology is also presented in this paper.

Multi-axial Vibration Testing Methodology of Vehicle Component (자동차 부품에 대한 다축 진동내구 시험방법)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Dong-Won;Kwon, Seong-Jin;Lee, Bong-Hyun;Na, Byung-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.297-302
    • /
    • 2007
  • Vibrating test of vehicle component can be possible in lab-based simulators instead of field testing owing to the development of technology in control algorithm as well as computational process. Currently, Multi-Axial Simulation Table(MAST) is recommended as a vibrating equipment, which excites a target component for 3-directional translation and rotation motion simultaneously and hence, vibrational condition can be fully approximated to that of real road test. But, the vibration-free performance of target component is not guaranteed with MAST system, which is only simulator subjective to the operator. Rather, the reliability of multi-axial vibration test is dependent on the quality of input profile which should cover the required severity of vibrating condition on target component. In this paper, multi-axial vibration testing methodology of vehicle component is presented here, from data acquisition of vehicle accelerations to the obtaining the input profile of MAST using severe data at proving ground. To compare the severity of vibration condition, between real road test and proving ground one, energy principle of equivalent damage is proposed to calculate energy matrices of acceleration data and then, it is determined the optimal combination of special events on proving ground which is equivalent to real road test at the aspects of vibration fatigue using sequential searching optimal algorithm. To explain the vibration methodology clearly, seat and door component of vehicle are selected as a example.

  • PDF

Multi-axial Vibration Test on MAST System with Field Data (국내도로 주행 시험을 통한 6축 진동시험 방법에 관한 연구)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bang-Hyun;Kwon, Seong-Jin;Na, Byung-Chul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.704-711
    • /
    • 2006
  • Vibration test on MAST(multi axial simulation table) system has several advantage over one-axial vibration test that could simulate 6-DOF, 3-axial translation and 3-axial moment, at the same time. Since field vibration motion can be fully represented with 6-DOF, multi-axial vibration test on vehicle component is widely conducted in technical leading companies to make sure its fatigue performance in vibration environment. On the way to fulfill the process, editing technique of obtained field data is key issue to success a reliable vibration testing with MAST system. Since the original signals are not only too large to fulfill it directly, but all of the measured data is not guarantee its convergency on generating its driving files, editing technique of the original signals are highly required to make some events that should meet the equal fatigue damage on the target component In this paper, key technique on editing a field data feasible for MAST system is described based on energy method in vibration fatigue. To explain its technique explicitly, author first introduced a process on field data acquisition of two vehicle component and then, representing events are produced to keep up with the editing strategy about a energy method. In the final chapter, a time information regarding a vibration test on MAST system is derived from the energy data which is critical information to perform a vibration test.

MAST Vibration on MAST System with Field Data (국내도로 주행 시험을 통한 6축 진동시험 방법에 관한 연구)

  • Kim, Chan-Jung;Bae, Chul-Yong;Lee, Bong-Hyun;Kwon, Seong-Jin;Na, Byung-Chul
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.764-769
    • /
    • 2006
  • Vibration test on MAST(multi axial simulation table) system has several advantage over one-axial vibration test that could simulate 6-DOF, 3-axial translation and 3-axial moment, at the same time. Since field vibration motion can be fully represented with 6-DOF, multi-axial vibration test on vehicle component is widely conducted in technical leading companies to make sure its fatigue performance in vibration environment. On the way to fulfill the process, editing technique of obtained field data is key issue to success a reliable vibration testing with MAST system. Since the original signals are not only too large to fulfill it directly, but all of the measured data is not guarantee its convergency on generating its driving files, editing technique of the original signals are highly required to make some events that should meet the equal fatigue damage on the target component In this paper, key technique on editing a field data feasible for MAST system is described based on energy method in vibration fatigue. To explain its technique explicitly, author first introduced a process on field data acquisition of two vehicle component and then, representing events are produced to keep up with the editing strategy about a energy method. In the final chapter, a time information regarding a vibration test on MAST system is derived from the energy data which is critical information to perform a vibration test.

  • PDF

Generating Method of the Input Profile in the MAST System (자동치부품(시트, 도어) 6축 진동 재현을 위한 가진 프로파일 생성 기법)

  • Lee, Bong-hyun;Kim, Gi-Hoon;Kim, Chan-jung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.9 s.102
    • /
    • pp.1070-1076
    • /
    • 2005
  • Vibration test using the MAST(multi axial simulation table) provide a more reliable testing environment than any conventional one. The multi axial simulation could be possible with a advanced control algorithm and hardware supports so that most of the operation is automatically conducted by MAST system itself except the input information that is synthesized by the measured response signals. That means the reliability of the vibration test is highly depended on the quality of the input profile. In this paper, the optimal algorithm based on the energy method is introduced to construct a best combination of candidated input PSD data could be constructed. Since the optimal algorithm renders time information, the nitration fatigue test is completely possible for any measured signals one wants. The proposed method is explained with representing acquired road signals from the candidate input PSD obtained from a proving ground.

Generation of the Input Profile for Fatigue Vibration Testing in MAST System (자동차부품(시트,도어) 6축 진동 재현을 위한 가진 프로파일 생성 기법)

  • Kim, Chan-Jung;Beak, Gyoung-Won;Lee, Bong-Hyun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.413-418
    • /
    • 2005
  • Vibration test using the MAST(Multi Axial Simulation Table) is more reliable test than conventional testing process focused on one directional vibration test. The former test could be possible with a advanced control algorithm and hardware supports so that most of the operation is automatically conducted by MAST system itself except the input information that is derived from the measured data. That means the reliability of the vibration test is highly depended on the input profile than any other cases before. In this paper, the optimal algorithm based on energy method is introduced so that the best combination of candidated input PSD data could be constructed. The optimal algorithm renders time information so that the vibration fatigue test is completely possible for any measured signals one wants. The real road test is conducted in short intervals containing some rough roads and the candidated input PSD is obtained from the extra road in proving ground. The testing is targeted for the electronically operated door and seat.

  • PDF

Material Characteristics of Dental Implant System with In-Vitro Mastication Loading

  • Jeong, Tae-Gon;Jeong, Yong-Hun;Lee, Su-Won;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Gang, Gwan-Su
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.72-72
    • /
    • 2018
  • A dynamic fatigue characteristic of dental implant system has been evaluated with applying single axial compressive shear loading based on the ISO 14801 standard. For the advanced dynamic fatigue test, multi-directional force and motion needed to be accompanied for more information of mechanical properties as based on mastication in oral environment. In this study, we have prepared loading and motion protocol for the multi-directional fatigue test of dental implant system with single (Apical/Occlusal; AO), and additional mastication motion (Lingual/Facial; LF, Mesial/Distal; MD). As following the prepared protocol (with modification of ISO 14801), fatigue test was conducted to verify the worst case results for the development of highly stabilized dental implant system. Mechanical testing was performed using an universal testing machine (MTS Bionix 858, MN, USA) for static compression and single directional loading fatigue, while the multi-directional loading was performed with joint simulator (ADL-Force 5, MA, USA) under load control. Basically, all mechanical test was performed according to the ISO 14801:2016 standard. Static compression test was performed to identify the maximum fracture force with loading speed of 1.0 mm/min. A dynamic fatigue test was performed with 40 % value of maximum fracture force and 5 Hz loading frequency. A single directional fatigue test was performed with only apical/occlusal (AO) force application, while multi directional fatigue tests were applied $2^{\circ}$ of facial/lingual (FL) or mesial/distal (MD) movement. Fatigue failure cycles were entirely different between applying single-directional loading and multi-directional loading. As a comparison of these loading factor, the failure cycle was around 5 times lower than single-directional loading while applied multi-directional loading. Also, the displacement change with accumulated multi-directional fatigue cycles was higher than that of single directional cycles.

  • PDF

Vibration and Stability Analysis of a Multi-stepped Shaft System of Turbo Compressor (터보 압축기 다단 회전축계의 진동 및 안정성 연구)

  • Seo, Jung-Seok;Kang, Sung-Hwan;Park, Sang-Yoon;An, Chang-Gi;Song, Ohseop
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.8
    • /
    • pp.583-591
    • /
    • 2014
  • The mathematical modeling on the free vibration and stability of a multi-stepped shaft of turbo compressor is performed in this study. The multi-stepped shaft is modeled as a non-uniform Timoshenko beam supported by anisotropic bearings. It is assumed that the shaft is spinning with constant speed about its longitudinal axis and subjected to a conservative axial force induced by front and rear impellers attached to the shaft. The structural model incorporates non-classical features such as transverse shear and rotary inertia. A structural coupling between vertical and lateral motions is induced by Coriolis acceleration terms. The governing equations are derived via Hamilton's variational principle and the equations are transformed to the standard form of an eigenvalue problem. The implications of combined gyroscopic effect, conservative axial force, bearing stiffness and damping are revealed and a number of pertinent conclusions are outlined. In this study analytical results are compared with those from ANSYS finite element analysis and experimental modal testing.

Evaluation of Dynamic Properties through Large Triaxial Test : Development and Verification of Apparatus (대형삼축압축실험을 이용한 동적물성 산정 : 장비구축 및 검증)

  • Lee, Sung-Jin;Kim, Yun-Ki;Lee, Jun-S.;Hwang, Seon-Keun;Park, Jae-Jun
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.640-649
    • /
    • 2010
  • Coarse granular materials such as gravel and crushed stone have been used as an important fill materials to large soil structure of railway, road, dam and so on. Although much studies for general soil materials have been carried out domestically, the studies for coarse materials were insufficient. Particularly, it is the level in which the study for dynamic properties(Elastic modulus and damping ratio) of coarse materials, applies the foreign country literature. This is due to the lack of large equipment for element test. But large soil structures made of coarse granular materials are generally important infrastructures. Therefore, the reliable design parameters for coarse materials should be obtained for safe and economic design, construction and maintenance. Triaxial test is the laboratory test method that is capable of controlling a confining pressure and boundary condition. In this project, we made a multi-purpose large triaxial testing system. This testing system is able to test coarse granular materials with maximum particle diameter of 100mm and support both the load control and displacement control. The load cell is installed inside of triaxial cell and the axial displacement is measured locally in order to control and measure more accurately in the small strain level. The verification test of this testing system was carried out with urethane verification specimens. So, from now on the useful information for coarse granular materials are expected to suggested by performing many tests with various material and condition.

  • PDF