• 제목/요약/키워드: movable base

검색결과 26건 처리시간 0.021초

다이케스팅 머신의 구조 해석

  • 윤승원
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.813-817
    • /
    • 1995
  • Structural analysis of horizontal cold chamber die casting machine is performed by the FEM. The analyzed model is made up of stationary die platen,movable die platen,link housing platen, C-frame, and tie bar which mainly undertake die locking force and injection force. In modeling, compression gap elements are used for to simulate contacting condition between tie bar and movable die platen, movable die platen and base frame, and link housing and base frame. Unbalanced die locking force imposed on four tie bars are considered. As the results, the deformed shape and the stresses of the die casting machine are given.

  • PDF

추가 이동 질량을 이용한 선형 모터용 반발력 보상 기구 (A Passive Reaction Force Compensation Mechanism for a Linear Motor Motion Stage using an Additional Movable Mass)

  • 응웬덕칸;안형준
    • 한국정밀공학회지
    • /
    • 제31권10호
    • /
    • pp.929-934
    • /
    • 2014
  • Reaction force compensation (RFC) mechanism can relieve the vibration of base system caused by acceleration and deceleration of mover. In this paper, we propose a new passive RFC mechanism with a movable additional mass to reduce vibration of the system base as well as displacement of the magnet track. First, equation of motion for the new passive RFC mechanism is derived and simulated to tune design parameters such as masses and spring coefficients. Simulation results show that the vibration of the system base of the stage with the new RFC mechanism.

해양심층수 이용형 이동식 해상양식시스템 개발 (I) (A Study on Development of Movable Mariculture System by Use of Deep Sea Water (I))

  • 김현주;정동호;최학선
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 추계학술대회 논문집
    • /
    • pp.329-332
    • /
    • 2003
  • Aquaculture have been important role to supply food resources for mankind. However, competitive power of domestic mariculture industry was declined due to increase of labor and feed expenditures, and quantity import of low-priced livefishes from the developing underdeveloped nations in North and South East Asia. Mass production and quality enhancement can be pointed out to overcome such an industrial environment in this decade. To meet these requirement, movable mariculture base remodeling feasible vessel of chemical tanker or crude oil carrier has been proposed for more advanced mariculture management system by using deep seawater from about 200m which is sustainablely clean, nutrient-rich and cold seawater. Deep seawater can be applied for control of seawater temperature for mariculture base and cultivation phytoplankton and seaweed as feed. Besides mariculture, strategic marketing can be implemented by raw water and ice of deep seawater. Feasibility of applying deep seawater was considered after evaluating general movable mariculture base and management system.

  • PDF

임상가를 위한 특집 2 - 총의치 발달의 역사와 교합원리 (The developmental history of Complete denture and its occlusal principle)

  • 임영준;주용훈;이진한
    • 대한치과의사협회지
    • /
    • 제50권1호
    • /
    • pp.13-21
    • /
    • 2012
  • In an edentulous situation, the dentist must make several determinations when constructing artificial teeth. These include vertical and horizontal relationships of mandible with respect to the maxilla, occlusal form and position, vertical dimension, occlusal relationships during both centric closure and eccentric excursive movements. Artificial teeth are attached to a movable base resting on movable and displaceable living tissue subject to damage. They act as a unit; therefore, they must be arranged to function as a unit. Bilateral balanced occlusion is that stability of the denture is attained when bilateral contacts ex ist throughout all dynamic and static states of the denture during function. Lateral excursion in a balanced scheme implies simultaneous working side and nonworking side contact, while occlusal contacts are maintained on both anterior and posterior teeth as the mandible moves anteriorly into protrusion.

Seismic responses of a free-standing two-story steel moment frame equipped with a cast iron-mortar sliding base

  • Chung, Yu-Lin;Kuo, Kuan-Ting;Nagae, Takuya;Kajiwara, Koichi
    • Earthquakes and Structures
    • /
    • 제17권3호
    • /
    • pp.245-256
    • /
    • 2019
  • An experimental study was conducted to evaluate the dynamic behavior of a free-standing frame equipped with a movable base system using cast iron and mortar as the bearing materials. The preliminary friction test indicated that a graphite layer developed on the interface and exhibited stable friction behavior. The friction coefficient ranged from 0.33 to 0.36 when the applied normal compression stress ranged from 2.6 to 5.2 MPa. The effect of the variation of normal compression stress would be small. Shaking table tests on the free-standing frame showed that rock, slide, and rock-slide responses occurred. The cumulative slide distance reached 381 mm under JMA Kobe wave excitation; however, only a few cyclic slides occurred at the same locations along the moving track. Most surfaces sustained single slides. Similar results can be observed in other shaking conditions. The insufficient cyclic sliding and significant rocking resulted in a few graphite layers on the mortar surfaces. Friction coefficients were generally similar to those obtained in the preliminary friction tests; however, the values fluctuated when the rocking became significant. The collisions due to rocking caused strong horizontal acceleration responses and resulted in high friction coefficient. In addition, the strong horizontal acceleration responses caused by the collisions made the freestanding specimen unable to reduce the input horizontal acceleration notably, even when slippage occurred. Compared with the counterpart fixed-base specimen, the specimen equipped with the iron-mortar base could reduce the horizontal acceleration amplification response and the structural deformation, whereas the vertical acceleration response was doubled due to collisions from rocking.

Design of the Pattern Adjustable Base Station Antenna for WCDMA Applications

  • Lee, Sang-Ho;Lee, Jung-Nam;Lee, Don-Shin;Park, Jong-Kweon;Kim, Hak-Sun
    • Journal of electromagnetic engineering and science
    • /
    • 제8권2호
    • /
    • pp.64-69
    • /
    • 2008
  • In this paper, we have proposed the pattern adjustable base station antenna for WCDMA applications. The proposed antenna consists of an omni-antenna(sleeve monopole) and two movable reflectors. The two reflectors can be controlled by mechanically and used to adjust the horizontal pattern of the base station antenna. The antenna was designed, fabricated, and measured. The antenna covers the entire WCDMA band for VSWR<1.4. The measured antenna gain is more than 15 dBi over the operating frequency range. By changing the angle (a) and the distance (d) of the antenna, the pattern adjustment of the proposed base station antenna is found to be possible.

이동형 아스팔트 재생기를 이용한 페아스팔트 콘크리트 혼합물의 재활용 (The Recycling of Waste Asphalt Concrete Mixfure Using a Movable Asphalt Recycling Machine)

  • 박승범;조청휘;김정환
    • 한국산학기술학회논문지
    • /
    • 제1권2호
    • /
    • pp.75-83
    • /
    • 2000
  • 최근 경제성장 및 국민 생활향상에 따라 폐기물 발생량이 급격하게 증대되어 그 처리문제가 심각해지고 있다. 이러한 폐기물중 노고 포장의 해체 및 유지·보수공사의 증가에 따라 다량 발생하고 있는 폐아스콘은 대부분 재활용되지 못하고 불법처분 또는 매립되고 있어 자원낭비 및 심각한 환경오염 문제를 야기하고 있는 실정이다. 따라서 본 연구에서는 폐아스콘의 재활용을 촉진하기 위하여 이동형 아스팔트 재생기 및 재생첨가제를 사용하여 양질의 신재 아스콘과 동등 수준의 품질을 갖춘 기층용 재생아스콘을 제조하기 위한 기초적 연구를 수행하였다.

  • PDF

원자력발전소 가압기 점검보수 로봇의 최적화 설계 (Optimal design of robot for inspection and maintenance of pressurizer in the nuclear power plant)

  • 엄재섭;정승호;김승호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.1696-1699
    • /
    • 1997
  • The robot mainpulator for inspection of pressurizer in the nuclear power plant has been developed, which consists of four parts : 2 arms, movable gripper, base frame, contorl console. To extract the damaged electric heating rod inside pressurizer, the gripper has been developed using wire lope and self-locking mechanism. for the examination of the structural stability of the robot manipulator, stress analysis is performed by using the ANSYS code.

  • PDF

PL 판정을 위한 저압용 스위치의 소손 패턴 해석기법 (Analysis Method for Damage Patterns of Low Voltage Switches for PL Judgment)

  • 최충석
    • 한국화재소방학회논문지
    • /
    • 제24권5호
    • /
    • pp.136-141
    • /
    • 2010
  • 본 연구에서는 옥내 조명 설비의 전원을 ON/OFF 하기 위해 사용되는 저압용 스위치의 구조 및 발열 메커니즘을 제시하고, 에너지원의 종류에 따라 스위치의 고정금구 및 가동 접점 등의 소손패턴을 제시함으로써 향후 예상되는 PL 분쟁의 판단 근거를 확보하는데 있다. 스위치에 인가된 일반 화염은 한국산업규격(KS)의 난연성 시험 방법을 적용하였다. 또한 스위치에 공급된 전류는 대전류공급장치(PCITS)를 이용하였다. 실험이 진행될 때 주위의 온도는 $22{\pm}2^{\circ}C$, 습도는 40~60%를 유지시켰다. 스위치의 발열은 배선과 클립의 접속 불량, 가동 접점의 절연 열화 및 접촉 불량 등에 의해서 생성되는 것으로 판단된다. 일반 화염에 의해 소손된 스위치는 표면이 균일하게 탄화되었으며, 화원을 제거하면 자연 소화되었다. 일반화염에 의해 탄화된 스위치를 분해한 결과 고정금구 및 가동 접점 등은 비교적 양호한 형태를 보였으나 외함, 클립 지지대, 가동 접점, 표시램프 등에서 탄화 및 변색을 확인할 수 있었다. 과전류에 의해 소손된 스위치는 배선을 연결하는 클립 및 클립 지지대 등은 소손의 흔적이 거의 없으나 고정금구, 가동 접점, 표시 램프 등은 심하게 탄화되었다. 즉 접촉 저항이 큰 부분에서 집중적으로 소손되었고 내부에서 외부로 탄화가 진행되는 패턴을 나타냈다. 따라서 소손된 스위치의 탄화 패턴 및 금속 금구류의 특성을 분석하면 최초의 에너지원 판정이 가능하다.

마이크로포지셔닝 병렬평행기구의 개발 및 실험 (Development and Experiment of a Micropositioning Parallel Manipulator)

  • 차영엽;윤권하
    • 제어로봇시스템학회논문지
    • /
    • 제15권5호
    • /
    • pp.543-547
    • /
    • 2009
  • This paper describes the design, simulation, development, and experiment of a six degree-of-freedom micropositioning parallel manipulator. A movable stage was supported with six links, each of which extends with a dc-servo micropositioning actuator. In case of parallel manipulator, while the solution of the inverse kinematics is easily found by the vectors of the links which are composed of the joint coordinates in base and platform, but forward kinematic is not easily solved because of the nonlinearity and complexity of the parallel manipulator's kinematic output equation with the multi-solutions. The movable range of the prototype was ${\pm}25mm$ in the x- and y-directions and ${\pm}12.5mm$ in the z-direction. The minimum incremental motion of the prototype was $1{\mu}m$ in the x- and y-directions and $0.5{\mu}m$ in the z-direction. The repeatability of the prototype was ${\pm}2{\mu}m$ in the x- and y-directions and ${\pm}1{\mu}m$ in the z-direction. The motion performance was also evaluated by not only the computer simulation of CAD model but also the experiment using a capacitive sensor system.