• Title/Summary/Keyword: motors

Search Result 3,621, Processing Time 0.029 seconds

Kinesin Superfamily KIF5 Proteins Bind to ${\beta}III$ Spectrin

  • Paik, Jae-Eun;Kim, Na-Ri;Yea, Sung-Su;Jang, Won-Hee;Chung, Joon-Young;Lee, Sang-Kyoung;Park, Yeong-Hong;Han, Jin;Seog, Dae-Hyun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.8 no.3
    • /
    • pp.167-172
    • /
    • 2004
  • The kinesin proteins (KIFs) make up a large superfamily of molecular motors that transport cargo such as vesicles, protein complexes, and organelles. KIF5 is a heterotetrameric motor that conveys vesicles and plays an important role in neuronal function. Here, we used the yeast two-hybrid system to identify the neuronal protein(s) that interacts with the tail region of KIF5 and found a specific interaction with ${\beta}III$ spectrin. The amino acid residues between 1394 and 1774 of ${\beta}III$ spectrin were required for the interaction with KIF5C. ${\beta}III$ spectrin also bound to the tail region of neuronal KIF5A and ubiquitous KIF5B but not to other kinesin family members in the yeast two-hybrid assay. In addition, these proteins showed specific interactions, confirmed by GST pull-down assay and co-immunoprecipitation. ${\beta}III$ spectrin interacted with GST-KIF5 fusion proteins, but not with GST alone. An antibody to ${\beta}III$ spectrin specifically co-immunoprecipitated KIF5s associated with ${\beta}III$ spectrin from mouse brain extracts. These results suggest that KTF5 motor proteins transport vesicles or organelles that are coated with ${\beta}III$ spectrin.

Estimation Method of Cable Fault Location in Rocket Motors Using M-sequence Signals (M시퀀스 신호를 이용한 로켓 추진기관 케이블 결함 위치 추정 기법)

  • Son, Ji-Hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.84-92
    • /
    • 2020
  • This paper describes the estimation method of cable fault location in rocket motors using M-sequence (Maximal Length Sequence). In order to estimate the location of a cable fault, three methods have been usually used: TDR (Time Domain Reflectometry), FDR (Frequency Domain Reflectometry), and TFDR (Time-Frequency Domain Reflectometry). However, these methods suffer the disadvantage of requiring users to be close to a test field, which is dangerous. The estimation method of cable fault location using M-sequence is proposed to solve this problem. The proposed method can make use of DAS (Data Acquisition System). The experiments were three cases: damaged, open, and short. The RG-58 coaxial cable was used in the experiments. As a result, the proposed method has better performance than that of conventional methods such as TDR and TFDR.

Sliding Mode Control Based on 3-Loop of a Pneumatic Motor (공압모터의 3-루프 기반 슬라이딩 모드 제어)

  • Kim, Geun-Mook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6446-6451
    • /
    • 2014
  • Pneumatic motors are quite attractive for many applications because of their competitive price, light-weight, easy assembly, safety in hazardous areas as well as other features, such as a good force/weight ratio and operation in exceptionally harsh environments. In contrast to these advantages, pneumatic motors have limited use in applications, particularly those requiring a fast and precise response. These undesirable characteristics are due to the high compressibility of air and from the nonlinearities in pneumatic systems. This paper presents the sliding mode controller based on 3-loop(SMCB3L), which increases the load stiffness to control the rotation angle of a pneumatic motor. The characteristics for the step responses and load disturbances of the proposed controller were compared with the conventional PID controller. The experimental results showed that a properly designed SMCB3L is capable of high positioning accuracy within ${\pm}0.05mm$. Furthermore, the load stiffness of the SMCB3L can be improved 3.5 fold compared to that of PID controllers.

Development of Dual Pulse SRM (이중펄스 고체추진기관 개발)

  • Rho, Tae-Ho;Lee, Won-Bok;Cho, Won-Man
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.69-72
    • /
    • 2011
  • The ground tests of the dual pulse solid rocket motors(SRM) were performed to prove the performance of the developed dual pulse solid rocket motors. To achieve dual pulse, pulse seperation device(PSD) and independent ignition systems were installed between the 1st pulse motor and the 2nd pulse motor. The three major development goals are as follow. First, the total impulse of the dual pulse SRM must be over 90% of the single SRM which has same envelopment and weight. Second, the ignition of the 2nd pulse motor can be started at any time between 0 and 60 seconds after termination of the 1st pulse motor. Last, the rupture disk of PSD must not be broken at the 1st pulse pressure, but be broken at below 30% of the 2nd pulse operating pressure. The results of the ground tests satisfied the development goals.

  • PDF

Diagnosis of Induction Motor Faults Using Inverter Input Current Analysis (인버터 입력전류 분석을 이용한 유도전동기 고장진단)

  • Han, Jungho;Song, Joong-Ho;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.492-498
    • /
    • 2016
  • It is well known that since abrupt faults in induction motors tend to lead to subsequent faults and deterioration of the drive apparatus, motor faults may lead to several operating restrictions, such as security problems and economic loss. A lot of research has been done in the area of diagnosis to detect machine faults and to prevent catastrophic hazards in the motor drive system. This paper presents a new method of motor current signature analysis in which the DC-link current of the inverter-driven induction motor system, where a single current sensor is employed instead of three AC current sensors, is measured, and fast Fourier transform analysis is performed. This proposed method makes it possible to easily discern and clearly separate the motor fault current signature from the normal operation current flowing through the stator and rotor windings.

Implementation of PC based Motor Fault Diagnosis System (PC 기반 전동기 고장 진단 시스템의 구현)

  • Doo, Seung-Ho;Park, Jin-Bae;Kwak, Ki-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07d
    • /
    • pp.2195-2196
    • /
    • 2006
  • This study is for implementation of PC based Motor fault diagnosis system. By using harmonics and current signals of the motor, this system diagnoses the motor condition by accumulated harmonic contribution rate. In this proposed system that was composed of 5 parts. A sensor, connection box, evaluation board, device server, and main computer are those. There were two types of sensor, one was harmonic sensor the other was current sensors. The signal was acquired by sensor, and transferred to evaluation board. Second one is connection box. Because the output type of sensor and input type of evaluation board is different, connection box was necessary. Third one was evaluation board. The signal from the sensor was converted to digital signal in evaluation board. And this signal was transferred to device server. Fourth one was device server. Device server transferred the data from evaluation board to main computer. And the last one was other parts controlled by main computer. In main computer, there were communication and diagnosis algorithms. The result was derived by main computer. In the result, there were 12 categories and 5 levels of motor conditions. The proposed system had some advantages comparing with stand alone type commercial motor fault diagnosis system. The first, by using remote access it was easier to get the conditions of motor. The second, there was no need to handle the sensors when users measured the motor signals. By this property, no one was necessary at motor location site. The third, this system was less restricted by times and places than commercial stand alone type diagnosis system. Therefore users can operate this system only using the main computer. Once the sensors are installed at the motor, users doesn't need to move to check up the condition of motors. Moreover, if there is ethernet hub, many motors can be not only diagnosed at once but also decreased its cost.

  • PDF

Implementation of PC based Motor Fault Diagnosis System (PC 기반 전동기 고장 진단 시스템의 구현)

  • Doo, Seung-Ho;Park, Jin-Bae;Kwak, Ki-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.563-564
    • /
    • 2006
  • This study is for implementation of PC based Motor fault diagnosis system. By using harmonics and current signals of the motor, this system diagnoses the motor condition by accumulated harmonic contribution rate. In this proposed system that was composed of 5 parts. A sensor, connection box, evaluation board, device server, and main computer are those. There were two types of sensor, one was harmonic sensor the other was current sensors. The signal was acquired by sensor, and transferred to evaluation board. Second one is connection box. Because the output type of sensor and input type of evaluation board is different, connection box was necessary. Third one was evaluation board. The signal from the sensor was converted to digital signal in evaluation board. And this signal was transferred to device server Fourth one was device solver. Device server transferred the data from evaluation board to main computer. And the last one was other parts controlled by main computer. In main computer, there were communication and diagnosis algorithms. The result was derived by main computer. In the result, there were 12 categories and 5 levels of motor conditions. The proposed system had some advantages comparing with stand alone type commercial motor fault diagnosis system. The first, by using remote access it was easier to get the conditions of motor. The second, there was no need to handle the sensors when users measured the motor signals. By this Property, no one was necessary at motor location site. The third, this system was less restricted by times and places than commercial stand alone type diagnosis system. Therefore users can operate this system only using the main computer. Once the sensors are installed at the motor, users doesn't need to move to check up the condition of motors. Moreover, if there is ethernet hub, many motors can be not only diagnosed at once but also decreased its cost.

  • PDF

A Study on Rotor Position Detection and Securing Initial Position for Switched Reluctance Motor (SRM) (스위치드 릴럭턴스 전동기 (SRM) 회전자 위치 검출 및 초기 위치확보 연구)

  • Jeong, Sungin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.20 no.3
    • /
    • pp.141-146
    • /
    • 2020
  • In brushless DC motors (BLDC), the on/off angle of the switch is determined by the optimal alignment of the stator and rotor, while switched reluctance motors (SRM) are complex parameters with many on/off angles of the switch. It appears as a function and therefore the switching angle is variable for optimal operation. Therefore, in order to operate the switched reluctance motor (SRM) optimally, the rotor position can be detected using a high resolution position sensor and a complicated additional circuit. In this paper, rotor position detection and related position detection circuits are applied and detected by using various sensors such as encoder, hall sensor and opto interrupter among several methods to drive switched reluctance motor (SRM). Also a study on securing the initial position of the rotor was conducted.

Study on Pulse Separation Device of Bulkhead Type for Solid Rocket Motors (고체 추진기관의 격벽형 펄스분리장치 연구)

  • Cho, Won-Man;Kim, Won-Hoon;Chang, Hong-Been;Oh, Jong-Yun;Lee, Bang-Eop;Lee, Jong-Won
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.187-190
    • /
    • 2009
  • A multiple pulse rocket motor distributes the thrust energy more effectively compared to typical rocket motor as providing subsequent thrusts by the pulse motors of the missile. The pulse rocket motor is the advanced technology to improve an end game capability of the missile by increasing the range and final velocity. A pulse separation device is the core part of the pulse motor. The pulse separation device of bulkhead type was designed and developed. The elastic-plastic structural analysis of the bulkhead and rupture disc was conducted. Several air tests were also conducted to confirm the structural safety and acceptability about the design concept. Test results were compared with the analysis results, which showed reasonable agreements.

  • PDF

Numerical Analysis of Electromagnetic Radiation Characteristics by High Voltage and General Cables for Fuel Cell Electric Vehicle (FCEV) (수소 연료전지 차량용 고전압 케이블과 일반 케이블에 의한 차량 전자파 방사 특성 수치해석 연구)

  • Lee, Soon-Yong;Seo, Won-Bum;Lim, Ji-Seon;Choi, Jae-Hoon
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.2
    • /
    • pp.152-160
    • /
    • 2011
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) which is consisted of many motors in water pump, air blower, and hydrogen recycling pump as well as inverters for these motors is essential. Furthermore, there are also electric systems for entertainment, information, and vehicle control such as navigation, broadcasting, vehicle dynamic control systems, and so on. Since these systems are connected by high voltage or general cables, EMC (Electromagnetic compatibility) analysis for high voltage and general cable of FCEV is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields by high voltage and general cables for FCEVs is studied. From numerical analysis results, total time harmonic electromagnetic field strength from high voltage and general cables have difference of 13~16 dB due to ground effect by impedance matching. The EMI results of FECV at 10 m distance shows difference of 41 dB at 30 MHz and 54 dB at 230 MHz compared with only general cable routing.