• Title/Summary/Keyword: motion accuracy measurement

Search Result 192, Processing Time 0.029 seconds

Design of a pen-shaped input device using the low-cost inertial measurement units (저가격 관성 센서를 이용한 펜 형 입력 장치의 개발)

  • Chang, Wook;Kang, Kyoung-Ho;Choi, Eun-Seok;Bang, Won-Chul;Potanin, Alexy;Kim, Dong-Yoon
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.13 no.2
    • /
    • pp.247-258
    • /
    • 2003
  • In this paper, we present a pen-shaped input device equipped with accelerometers and gyroscopes that measure inertial movements when a user writes on 2 or 3 dimensional space with the pen. The measurements from gyroscope are integrated once to find the attitude of the system and are used to compensate gravitational effect in the accelerations. Further, the compensated accelerations are integrated twice to yield the position of the system, whose basic concept stems from the field of inertial navigation. However, the accuracy of the position measurement significantly deteriorates with time due to the integrations involved in recovering the handwriting trajectory This problem is common in the inertial navigation system and is usually solved by the periodic or aperiodic calibration of the system with external reference sources or other information in the filed of inertial navigation. In the presented paper, the calibration of the position or velocity is performed on-line and off-line. In the on-line calibration stage, the complementary filter technique is used, where a Kalman filter plays an important role. In the off-line calibration stage, the constant component of the resultant navigational error of the system is removed using the velocity information and motion detection algorithm. The effectiveness and feasibility of the presented system is shown through the experimental results.

Quantitative Assessment of Myocardial Infarction by In-111 Antimyosin Antibody (In-111-Antimyosin 항체를 이용한 심근경색의 정량적 평가)

  • Lee, Myung-Chul;Lee, Kyung-Han;Choi, Yoon-Ho;Chung, June-Key;Park, Young-Bae;Koh, Chang-Soon;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.25 no.1
    • /
    • pp.37-45
    • /
    • 1991
  • Infarct size is a major determinant of prognosis after acute myocardial infarction. Up to date, however, clinically available tests to estimate this size have not been sufficiently accurate. Twelve lead electrocardiogram and wall motion abnormality measurement are not quantitative, and creatine phophokinase (CPK) measurement is inaccurate in the presence of reperfusion or right ventricular infarction. Methods have been developed to localize and size acute myocardial infarcts with agents that are selectively sequestered in areas of myocardial damage, but previously used agents have lacked sufficient specificity. Antibodies that bind specifically only to damaged myocardial cells may resolve this problem and provide an accurate method for noninvasively measuring infarct size. We determined the accuracy with which infarcted myocardial mass can be measured using single photon emission computed tomography (SPECT) and radiolabeled antimyosin antibodies. Seven patients with acute myocardial infarction and one stable angina patient were injected with 2 mCi of Indium-111 labeled antimyosin antibodies. Planar image and SPECT was performed 24 hours later. None of the patients had history of prior infarcts, and none had undergone reperfusion techniques prior to the study, which was done within 4 days of the attack. Planar image showed all infarct patients to have postive uptakes in the cardiac region. The location of this uptake correlated to the infarct site as indicated by electrocardiography in most of the cases. The angina patient, however, showed no such abnormal uptake. Infarct size was determined from transverse slices of the SPECT image using a 45% threshold value obtained from a phantom study. Measured infarct size ranged from 40 to 192 gr. There was significant correlation between the infarct size measured by SPECT and that estimated from serial measurements of CPK (r=0.73, p<0.05). These date suggest that acute myocardial infarct size can be accurately measured from SPECT Indium-111 antimyosin imaging. This method may be especially valuable in situations where other methods are unreliable, such as early reperfusion technique, right ventricular infarct or presence of prior infarcts.

  • PDF

A study to 3D dose measurement and evaluation for Respiratory Motion in Lung Cancer Stereotactic Body Radiotherapy Treatment (폐암의 정위적체부방사선치료시 호흡 움직임에 따른 3D 선량 측정평가)

  • Choi, Byeong-Geol;Choi, Chang-Heon;Yun, Il-Gyu;Yang, Jin-Seong;Lee, Dong-Myeong;Park, Ju-Mi
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.59-67
    • /
    • 2014
  • Purpose : This study aims to evaluate 3D dosimetric impact for MIP image and each phase image in stereotactic body radiotherapy (SBRT) for lung cancer using volumetric modulated arc therapy (VMAT). Materials and Methods : For each of 5 patients with non-small-cell pulmonary tumors, a respiration-correlated four-dimensional computed tomography (4DCT) study was performed. We obtain ten 3D CT images corresponding to phases of a breathing cycle. Treatment plans were generated using MIP CT image and each phases 3D CT. We performed the dose verification of the TPS with use of the Ion chamber and COMPASS. The dose distribution that were 3D reconstructed using MIP CT image compared with dose distribution on the corresponding phase of the 4D CT data. Results : Gamma evaluation was performed to evaluate the accuracy of dose delivery for MIP CT data and 4D CT data of 5 patients. The average percentage of points passing the gamma criteria of 2 mm/2% about 99%. The average Homogeneity Index difference between MIP and each 3D data of patient dose was 0.03~0.04. The average difference between PTV maximum dose was 3.30 cGy, The average different Spinal Coad dose was 3.30 cGy, The average of difference with $V_{20}$, $V_{10}$, $V_5$ of Lung was -0.04%~2.32%. The average Homogeneity Index difference between MIP and each phase 3d data of all patient was -0.03~0.03. The average PTV maximum dose difference was minimum for 10% phase and maximum for 70% phase. The average Spain cord maximum dose difference was minimum for 0% phase and maximum for 50% phase. The average difference of $V_{20}$, $V_{10}$, $V_5$ of Lung show bo certain trend. Conclusion : There is no tendency of dose difference between MIP with 3D CT data of each phase. But there are appreciable difference for specific phase. It is need to study about patient group which has similar tumor location and breathing motion. Then we compare with dose distribution for each phase 3D image data or MIP image data. we will determine appropriate image data for treatment plan.

A Study on the Design of Functional Clothing for Vital sign Monitoring -Based on ECG Sensing Clothing- (생체신호 측정을 위한 기능성 의류의 디자인 연구 -심전도 센싱 의류를 중심으로-)

  • Cho, Ha-Kyung;Song, Ha-Young;Cho, Hyeon-Seong;Goo, Su-Min;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.13 no.3
    • /
    • pp.467-474
    • /
    • 2010
  • Recently, Study of functional clothing for Vital sensing is focused on reducing artifact by human motions, in order to enhance the electrocardiogram(ECG) sensing accuracy. In this study, considering the factors for each element found from the analysis, a 3-lead electrode inside textile embroidered with silver yarn was developed, and draft designs off our types of vital-signal sensing garments, which are 'chest-belt typed' garment, 'cross-typed' garment 'x-typed' garment and 'curved x-typed' garment, were prepared. The draft designs were implemented on a sleeveless male shirt made of an elastic material so that the garment and the electrodes can remain closely attached along the contour of the human body, and the acquired data was sent to the main computer over a wireless network. In order to evaluate the effects caused by body movements and the ECG-sensing capability for each type in static and dynamic states, displacements were measured from one and two dimensional perspectives. ECG measurement evaluation was also performed for Signal-to-noise ratio(SNR) analysis. Applying the experimental results, the draft garment designs were modified and complemented to produce two types of modular approaches 'continuous-attached' and 'insertion-detached' for the ECG-sensing smart clothing.

  • PDF

Improvement of Multi-beam Echo Sounder's Depth Accuracy (다중빔 음향측심기 수심 정확도 개선)

  • Choi Chul Eung;Kim Youn Soo;Suh Yong Cheol
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.1
    • /
    • pp.1-8
    • /
    • 2005
  • Multi-beam echo sounder is more precise and efficient than single beam echo sounder relatively because it is able to survey a wide area with 3 times or 4 times swath width as much as the depth of water using multi-beam echo sounder. It is sure to be needed to control supplementary equipment accurately, however, because the principle of creation and measurement of the beam is elaborate and influenced a great deal by vessel's motion. We analyzed using visual and statistical methods in both sections of the depth of water where were the places of the center of the beam and ± 45° angles from the central beam to improve the precise of Multi-beam echo sounder in this study. In result, it was required to control supplementary equipment because of errors from the vibration of an inertia governor and misalignment of extra units. Therefore, we reduced the vibration from the vessel's engine by sticking rubbers to the inertia governor and measured the offset values of extra units accurately, converted them to the values of horizontal position and lined up. In result, the precise in sounding the depth at the place of ± 45° from the center of the beam was improved from the level of the 1st order to the special order in a hydrographic survey of the IHO S44 standards and a phenomenon of ripple patterns in the overlapped area by misalignment was decreased remarkably.

Precise Relative Positioning for Formation Flying Satellite using GPS Carrier-phase Measurements (GPS 반송파 위상을 사용한 편대비행위성 상대위치결정 연구)

  • Park, Jae-Ik;Lee, Eunsung;Heo, Moon-Beom
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.12
    • /
    • pp.1032-1039
    • /
    • 2012
  • The present paper deals with precise relative positioning of formation satellites with long baseline in low Earth orbit making use of L1/L2 dual frequency GPS carrier phase measurements. Kinematic approach means to describe the motion of objects without taking its mass/dynamics model into consideration. The advantage of the kinematic approach is that information about dynamics of the system is not applied, which gives more flexibility and could improve the scientific interest of the observations made by the mission. The ionosphere terms, which are not canceled by double differenced measurement equation in the case of the long baseline, are explicitly estimated as unknown parameters by extended Kalman filter. The estimated float ambiguities by EKF are solved by existing efficient integer vector search strategy under integer least square condition. For the integer vector search, we employ well known MLAMBDA. Finally, The feasibility and accuracy of processing scheme are demonstrated using the GPS measurements for two satellites in low Earth orbit separated by baselines of 100 km.

A Study on the 3D Reconstruction and Historical Evidence of Recumbent Buddha Based on Fusion of UAS, CRP and Terrestrial LiDAR (UAS, CRP 및 지상 LiDAR 융합기반 와형석조여래불의 3차원 재현과 고증 연구)

  • Oh, Seong-Jong;Lee, Yong-Chang
    • Journal of Cadastre & Land InformatiX
    • /
    • v.51 no.1
    • /
    • pp.111-124
    • /
    • 2021
  • Recently, Interest in the restoration and 3D reconstruction of cultural properties due to the fire of Notre Dame Cathedral on April 15, 2019 has been focused once again after the 2008 Sungnyemun fire incident in South Korea. In particular, research to restore and reconstruct the actual measurement of cultural properties using LiDAR(Light Detection and ranging) and conventional surveying, which were previously used, using various 3D reconstruction technologies, is being actively conducted. This study acquires data using unmanned aerial imagery of UAV(Unmanned Aerial Vehicle), which has recently established itself as a core technology in the era of the 4th industrial revolution, and the existing CRP(Closed Range Photogrammetry) and terrestrial LiDAR scanning for the Recumbent Buddha of Unju Temple. Then, the 3D reconstruction was performed with three fusion models based on SfM(Structure-from-Motion), and the reproducibility and accuracy of the models were compared and analyzed. In addition, using the best fusion model among the three models, the relationship with the Polar Star(Polaris) was confirmed based on the real world coordinates of the Recumbent Buddha, which contains the astronomical history of Buddhism in the early 11th century Goryeo Dynasty. Through this study, not only the simple external 3D reconstruction of cultural properties, but also the method of reconstructing the historical evidence according to the type and shape of the cultural properties was sought by confirming the historical evidence of the cultural properties in terms of spatial information.

Development of Steel Composite Cable Stayed Bridge Weigh-in-Motion System using Artificial Neural Network (인공신경망을 이용한 강합성 사장교 차량하중분석시스템 개발)

  • Park, Min-Seok;Jo, Byung-Wan;Lee, Jungwhee;Kim, Sungkon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6A
    • /
    • pp.799-808
    • /
    • 2008
  • The analysis of vehicular loads reflecting the domestic traffic circumstances is necessary for the development of adequate design live load models in the analysis and design of cable-supported bridges or the development of fatigue load models to predict the remaining lifespan of the bridges. This study intends to develop an ANN(artificial neural network)-based Bridge WIM system and Influence line-based Bridge WIM system for obtaining information concerning the loads conditions of vehicles crossing bridge structures by exploiting the signals measured by strain gauges installed at the bottom surface of the bridge superstructure. This study relies on experimental data corresponding to the travelling of hundreds of random vehicles rather than on theoretical data generated through numerical simulations to secure data sets for the training and test of the ANN. In addition, data acquired from 3 types of vehicles weighed statically at measurement station and then crossing the bridge repeatedly are also exploited to examine the accuracy of the trained ANN. The results obtained through the proposed ANN-based analysis method, the influence line analysis method considering the local behavior of the bridge are compared for an example cable-stayed bridge. In view of the results related to the cable-stayed bridge, the cross beam ANN analysis method appears to provide more remarkable load analysis results than the cross beam influence line method.

Evaluation of Average CT to Reduce the Artifact in PET/CT (PET/CT 검사에서 호흡에 따른 인공산물을 줄이기 위한 Average CT의 유용성)

  • Kim, Jung-Sun;Nam, Ki-Pyo;Park, Seung-Yong;Ryu, Jae-Kwang;Cha, Min-Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.3-7
    • /
    • 2010
  • Purpose: The usefulness of Positron Emission Tomography (PET) images in diagnosis, staging, recurrent and treatment response evaluation has already been known. However, tumors which are small size, located in lower lobe of lung or upper lobe of liver are shown misalignment, distortion and different Standard Uptake Value (SUV) by respiration in PET images. Therefore, if radiotherapy based on normal respiration, it may cause low treatment response or more side effects because targets which had to treat, out of treat range or over dose to normal tissue. The purpose of this study is to evaluate attenuation-correction with Average CT (ACT) for more accuracy SUV measurement and minimize artifact by respiration. Materials and Methods: 13 patients, who had tumors which are around the diaphragm, underwent ACT scan after Helical CT (HCT) scan with PET/CT (Discovery DSTE 8; GE Healthcare). We quantified the differences between attenuation corrected image with HCT and attenuation corrected image with ACT in artifact size and maximum SUV ($SUV_{max}$). Artifacts were evaluated by measurement of the curved photogenic area in the lower thorax of the PET images for all patients. $SUV_{max}$ was measured separately at the primary tumors. Analysis program was Advantage Workstation v4.3 (GE Healthcare). Patients were injected with 7.4 MBq (0.2 $mC_i$) per kg of $^{18}F$-FDG and scanned 1 hour after injection. The PET acquisition was 3 minute per bed. Results: Significantly lower artifact were observed in PET/ACT images than in PET/HCT images (below-thoracic artifacts caused by under corrected $1.5{\pm}3.5$ cm vs. $13.4{\pm}4.2$ cm). Significantly higher $SUV_{max}$ were noted in PET/ACT images than in PET/HCT images in the primary tumor. Compared with PET/HCT images, $SUV_{max}$ in PET/ACT images were higher by $5.3{\pm}3.9%$ (mean value) tumor. The highest difference was observed in Lower lobe of lung (7.7 to 8.7; 13%). Conclusion: Due to its significantly reduced artifacts in lower thoracic, attenuation corrected image with ACT images provided more reliable $SUV_{max}$ and may be helpful in monitoring treatment response. Moreover, ACT can separate upper lobe of liver and lower lobe of lung, it may be helpful in interpretation. ACT will be clinically useful, considering increased dose caused by ACT scan and adapt.

  • PDF

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF