• Title/Summary/Keyword: monomer mixture

Search Result 103, Processing Time 0.025 seconds

Studies on the Immobilization of Enzymes and Microoganism Part 1. Immobilizing Method of Glucose Oxidase by Gamma Radiation (효소 및 미생물의 고정화에 관한 연구 제1보. 방사선조사에 의한 Glucose Oxidase의 고정화법)

  • Kim, Sung-Kih
    • Microbiology and Biotechnology Letters
    • /
    • v.7 no.1
    • /
    • pp.1-8
    • /
    • 1979
  • A new method for immobilization of glucose oxidate by the aerobic gamma radiation of synthetic monomers was developed. The radiocopolymerization was conducted aerobically at -70 to -8$0^{\circ}C$ with the mixture of several polyfunctional esters, acrylates and native enzyme. The retained activity of immobilized glucose oxidase was about 50 to 55% when a NK 23G ester, acrylamide-bis and water mixture (1:1:2) in cold toluene treated with 450 krad of gam-ma radiation. The radiation dose did not influence significantly to the enzyme activity. The solvents used to prepare the beads of glucose oxidase and monomers were toluene, n-hexane, petoleum ether and chloroform. 0.05M tris-gycerol (pH 7.0) was a more suitable bugger solution for immobilizing the enzyme than was 0.02M phosphate. Immobilization of glucose oxidase shifted the optimum pH for its reaction from 6.0 to 6.5. The pH profile for the immobilized enzyme showed a broad range of optimum activity while the native enzyme gave a sharp pick for its optimum pH value. The immobilized enzyme reaction temperature was at the range of 30~4$0^{\circ}C$.

  • PDF

Radiation Induced-Grafting of Acrylic Acid onto Polyvinyl Chloride Fibers

  • Park, Jae-Ho;Lee, Chong-Kwang
    • Nuclear Engineering and Technology
    • /
    • v.8 no.2
    • /
    • pp.89-99
    • /
    • 1976
  • The grafting of acrylic acid in aqueous solution to polyvinyl chloride fibers tab been studied in the presence of ferrous, ferric, and cupric salts, The mutual irradiation technique was adopted using a Co-60 source or a Van do Graaff accelerator. The grafting and homopolymerization were suppressed by the cations. Particularly the grafting was suppressed by the cations in the following order of effectiveness : $Cu^{2+}$>$Fe^{2+}$>$Cu^{3+}$. The rate of grafting (in %/hr) was proportional to the 0.76th power of the dose rate over the range from 8.5f $10^3$ rad/hr to $1.4\times10^5$ rad/dr. The apparent activation energy for the grafting was determined to be 6.1 Kcal/mole between $25^{\circ}$ and $75^{\circ}C$ for the mixture of AA-HaO-$(CH_2Cl)_2$, containing Mohr's salt, $4\times10^{-3}$ mole/l. The increase of the grafting was observed when total dose and dose intensity were raised, or when ethylene dichloride as a swelling agent was saturated in the monomer mixture. The grafted polyvinyl chloride fibers showed considerable improvement in moisture regain, heat shrinkage, and melting properties, but tensile properties were not significantly affected by grafting.

  • PDF

Polymer Eyeglass Lens with Ultraviolet & High-Energy Visible Light Blocking Function for Eye Health (자외선 및 고에너지 가시광 차단 기능을 갖는 눈 건강을 위한 폴리머 안경렌즈)

  • Kim, Ki-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.12
    • /
    • pp.10-15
    • /
    • 2020
  • Ultraviolet rays, which have wavelengths smaller than 400 nm, are very harmful to the eyes. Recently, high-energy visible light was also revealed to be harmful to retinal cells. Therefore, polymer eyeglass lenses that can block UV and high-energy visible light are needed for eye health. In this study, high-refractive-index polymer eyeglass lens, n=1.67, were manufactured using the injection-mold method with the m-xylene diisocyanate monomer, 2,3-bis((2-mercaptoethyl)thio)-1-propanethiol monomer, benzotriazole UV absorber, release of alkyl phosphoric ester, dye mixture of CI solvent violet 13, and catalyst of dibutyltin dichloride mixture. A multi-layer anti-reflection coating was applied to manufactured polymer eyeglass lenses for both sides using an E-beam evaporation system. The optical properties of the manufactured lenses with the UV and high-energy visible light-blocking function were analyzed by UV-visible spectrophotometry. As a result, the polymer eyeglass lens with a UV absorber of 0.5 wt. % blocked 99% of UV and high-energy visible light shorter than 411 nm. The average transmittance of the polymer eyeglass lens with a UV absorber of 0.5wt.% was 97.9% in the range of 460 ~ 660 nm for photopic eye sensitivity higher than 10%. Therefore, clear image acquisition in photopic vision is possible.

Preparation and Characterization of Removal-type Acrylic Pressure-Sensitive Adhesive (4원 아크릴계 박리형 점착제의 제조와 특성에 관한 연구)

  • Seo, Young-Ok;Seul, Soo-Duk
    • Elastomers and Composites
    • /
    • v.36 no.4
    • /
    • pp.225-236
    • /
    • 2001
  • In order to improve the properties of the copolymer and the terpolymer that was used as removal-type pressure sensitive adhesive(PSA), we synthesized quaterpolymer with the variation of the types of monomer, initiator, and solvent, and concentration, the monomer/solvent ratio, reaction temperature and time. and determined the properties of this adhesive: the viscosity, molecular weight, conversion, solid content and structure of polymer. The prepared polymer was crosslinked by changing the type of crosslinking agent and concentration, and then we investigated the characteristics or adhesive such as peel adhesion, shear adhesion, heat resistance, weathering resistance and peel adhesion to aging. The optimum performance of RA/2- EHA/MMA/2-HEMA as a PSA were obtained when benzoyl peroxide was used as an initiator with the reactant mixture consisted of 80% BA and 2-EHA, 15%, MMA, and 5% 2-HFMA. The optimum reaction temperature and time were $80^{\circ}C$ and 8 hours, respectively. For BA/2-EHA/MMA/AA, the optimum performance was obtained when the polymerization was performed at the monomer composition of 80% BA/2-EHA, 15% MMA, and 5% AA. BPO was used as initiator and the optimum reaction temperature and time were identical to those of BA/2-EHA/MMA/ 2-HEMA. Isocyanate and melamine were used to crosslink BA/2-EHA/MMA/2-HEMA and BA/2-EHA/MMA/AA, respectively. No effect on the type of cross-linking agent on the peel adhesion was observed with aging. The quarterpolymers crosslinked with melamine left residues on the counter surface after weathering resistance test, while the polymers crosslinked with isocyanate did not.

  • PDF

Effect of CQ-amine ratio on the degree of conversion in resin monomers with binary and ternary photoinitiation systems

  • Moon, Ho-Jin;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.37 no.2
    • /
    • pp.96-103
    • /
    • 2012
  • Objectives: This study evaluated the effect of camphorquinone (CQ)-amine ratio on the C=C double bond conversion of resins with binary and ternary photoinitiation systems. Materials and Methods: Two monomer mixtures (37.5 Bis-GMA/37.5 Bis- EMA/25 TEGDMA) with binary systems (CQ/DMAEMA in weight ratio, group A [0.5/1.0] and B [1.0/0.5]) and four mixtures with ternary system (CQ/OPPI/DMAEMA, group C [0.1/1.0/0.1], D [0.1/1.0/ 0.2], E [0.2/1.0/0.1] and F [0.2/1.0/0.2]) were tested: 1 : 2 or 2 : 1 CQ-amine ratio in binary system, while 1 : 1 ratio was added in ternary system. The monomer mixture was cured for 5, 20, 40, and 300 sec with a Demetron 400 curing unit (Demetron). After each exposure time, degree of conversion (DC) was estimated using Fourier transform infrared (FTIR) spectrophotometer (Nicolet 520, Nicolet Instrument Corp.). The results were analyzed by ANOVA followed by Scheffe test, with p = 0.05 as the level of significance. Results: DC (%) was expressed in the order of curing time (5, 20, 40, and 300 sec). Group A ($14.63{\pm}10.42$, $25.23{\pm}6.32$, $51.62{\pm}2.69$, $68.52{\pm}2.77$); Group B ($4.04{\pm}6.23$, $16.56{\pm}3.38$, $37.95{\pm}2.79$, $64.48{\pm}1.21$); Group C ($16.87{\pm}5.72$, $55.47{\pm}2.75$, $60.83{\pm}2.07$, $68.32{\pm}3.31$); Group D ($23.77{\pm}1.64$, $61.05{\pm}1.82$, $65.13{\pm}2.09$, $71.87{\pm}1.17$); Group E ($28.66{\pm}2.92$, $56.68{\pm}1.33$, $60.66{\pm}1.17$, $68.78{\pm}1.30$); Group F ($39.74{\pm}6.31$, $61.07{\pm}2.58$, $64.22{\pm}2.29$, $69.94{\pm}2.15$). Conclusion: All the monomers with ternary photoinitiation system showed higher DC than the ones with binary system, until 40 sec. Concerning about the effect of CQ-amine ratio on the DC, group A converted into polymer more than group B in binary system. However, there was no significant difference among groups with ternary system, except group C when cured for 5 sec only.

Biosafety of the New Soft Contact Lens Materials in the Fibroblast L-929 Cell Line (흰쥐의 섬유아세포 L-929를 이용한 새로운 Soft Contact Lens 소재의 생물안전성 검증)

  • You, Young-Hyun;Nam, Joo-Hyeung;Kim, Bieong-Kil;Kim, Soon-Bok;Moon, Ik-Jae;Kim, Jong-Pil;Seu, Young-Bae
    • Microbiology and Biotechnology Letters
    • /
    • v.37 no.1
    • /
    • pp.75-79
    • /
    • 2009
  • In this study, we polymerized new materials for soft contact lens using HEMA (2-hydroxyethyl methacrylate) which is the based-monomer of soft contact lens, EGDMA (ethylene glycol dimethacrylate) as cross linkage agent, and the new additives of monoester or di-ester derived from itaconic acid commercially produced by the fermentation of Asp. itaconicus. New polymer materials for soft contact lens were synthesized with the mixture of HEMA and mono- or diester at different ratios and presented to a good water content and oxygen transmissibility (Dk/L) values. In case of polymerization with HEMA and mono-ester (15%), the water content and oxygen transmissibility of contact lens were found to be good values at 57.6% and 28.5 Dk respectively. The mixture of HEMA and mono-ester is more excellent than HEMA/di-ester in the water content and oxygen transmissibility. The toxicity of new contact lens materials were confirmed in the fibroblast L-929 cell line using a agar overlay test and a growth inhibition test with the extract solution of contact lens.

Application of Pervaporation Membrane Process in Petrochemical Industry (석유화학공업에서의 투과증발막의 응용)

  • Nam, Sang-Yong
    • Membrane Journal
    • /
    • v.17 no.1
    • /
    • pp.1-13
    • /
    • 2007
  • Pervaporation process using membrane is newly emerging energy saying and cost effect process instead of distillation process. Especially, in pertrochemical industry, pervaporation process is a strong candidate to substitute the conventional energy consuming processes because that petrochemical industry has much energy consuming separation processes, many azeotrope mixtures to separate and needs to compact space to install new process units. Aromatic/aliphatic separation including benzene/cyclohexane mixture, olefin/paraffin separation, xylene isomer separation, reactive monomer recovery and sulfur compound removal from gasoline have been inversitigated for the application of pervaporation membrane process by many researchers and are under commercializing.

Synthesis and Their Properties of PP Graft Copolymers by E-beam Radiation and Vapor Phase Reaction (전자선 조사 기상 반응에 의한 PP 기재 공중합체의 합성과 특성)

  • 황택성;박진원;이재천
    • Polymer(Korea)
    • /
    • v.26 no.3
    • /
    • pp.287-292
    • /
    • 2002
  • Graft copolymerization of styrene and glycidyl methacrylate (GMA) to the peroxidized polypropylene (PP) fabric with E-beam in $O_2$ atmosphere was carried out in vapor phase with benzoyl peroxide (BPO) as an initiator. The degree of grafting of copolymers was increased with the increase of the reaction temperature and the highest degree of grafting was obtained at $70^{\circ}C$ with styrene, and at $80^{\circ}C$ with GMA. The highest degree of grafting of styrene grafted PP according to reaction time was higher than that of GMA grafted PP. In vapor phase graft polymerization, the degree of grafting of copolymers according to water composition in monomer mixture was effected by the boiling temperature of monomers.

Effect of plasma polymerized film on fouling of heat exchangers

  • Kim, Ki-Hwan;Park, Sung-Chang;doo-Jin choi;Jung, Hyung-Jin;Ha, Sam-Chul;Kim, Chul-Hwan;Koh, Seok-Keun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1999.07a
    • /
    • pp.160-160
    • /
    • 1999
  • To reduce the fouling of heat exchangers, the plasma polymerized films was coated on the heat exchangers, and an effect of plasma polymerized film on fouling of heat exchangers was investigated. Monomer and reactive gases were used as the precursors of plasma polymerization. Plasma polymerized films were deposited with process parameters of pressure, power, and ratio of gases. Plasma polymerized films could be served as functional layers of good wettability and high resistance to corrosion. Wettability of plasma polymerized film could be controlled by the ratio change gas mixture. Hydrophilicity of plasma polymerized films on heat exchanger in air conditioner can provide improvement in performance of heat exchanger which results from good water drainage, decrease of pressure drop. DC-plasma polymerized films improve resistance to corrosion whcih is related to deposit formation in heat exchangers. The difference in the build up of fouling deposits between bare substrate and plasma polymerized substrate was investigated by scanning electron microscopy (SEM). An effect of plasma polymerized film on fouling of heat exchangers was discussed in terms of surface properties such as wettability, surface chemical state.

  • PDF

Biomimetic MIP Terpene Sensors Adding Conductive Polymers (전도성 고분자가 첨가된 생체 모방형 분자 각인 고분자 테르펜 센서)

  • Jung, Jae-Hun;Lee, Sung-Pil
    • Journal of Sensor Science and Technology
    • /
    • v.21 no.5
    • /
    • pp.345-351
    • /
    • 2012
  • Biomimetic terpene sensors which have high sensitivity and stability have been fabricated using moleculary imprinted polymer (MIP) technology. Since it is impossible to make a resistive type sensor due to the high resistance of MIP, we improved the sensor by adding conductive polymers. We investigated the sensitivity of resistive type sensors with nano particles depending on the amount of conductive polymers. The MIP membrane contained the methacrylic acid as functional monomer and ethylene glycol dimethacrylate as cross linker, which formed specific cavities originated by the target terpene molecules. The mixture of MIP and the conductive polymer was coated on the patterns of interdigit electrodes on the alumina substrate. The fabricated sensors showed their highest specific sensitivities exposed to 500 ppm target gases : limonene 0.055 at 40% of amount of conductive polymers and geraniol $5.84{\times}10^{-4}$ at 20% of amount of conductive polymers. In conclusion, we found that the terpene sensors are affected by the target molecules, functional monomers and the conductive polymers.