• Title/Summary/Keyword: monitoring technique

Search Result 2,200, Processing Time 0.04 seconds

A Study on Landscape Management Techniques of Cultural Heritage Designated Area Using 3D Mapping Method (3D맵핑을 이용한 문화재 지정구역 경관관리기법 연구)

  • Kim, Jae-Ung;Lee, Won-Ho;Shin, Hyun-Sil
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.36 no.1
    • /
    • pp.97-108
    • /
    • 2018
  • The purpose of this study is to propose the construction of a visibility analysis model, which is the basis of the analysis for landscape management on the heritage sites such as historic villages and scenic sites. Results of the visibility analysis using DEM and the visibility analysis of DSM based on 3D mapping data are compared as follows: Precision level of the extracted data was confirmed to be less than 6.5cm, based on RTK survey results produced by constructing orthoimage data and DSM from the digital data of 2cm-class GSD(Ground Sample Distance) obtained by using a small UAV(Unmanned Aerial Vehicle). As a result of comparing the visibility analysis data of Digital Surface Model (DSM) using a small UAV with Digital Elevation Model(DEM) applying the height of the building to the Digital Topographic Map, it was confirmed that more realistic visibility analysis can be accomplished by applying DSM, as the structures such as fences, trees, and houses are reflected in the topographic data. The visibility analysis model using the 3D mapping technique can efficiently obtain the constantly changing topographic information when needed, by immediately constructing the data by utilizing a small UAV. It seems to be possible to propose a reasonable analysis result for preservation management such as landscape evaluation of cultural property.

Bioequivalence of Atorva Tablet® to Lipitor Tablet® (Atorvastatin 20 mg) (리피토정® (아토르바스타틴 20 mg)에 대한 아토르바정®의 생물학적동등성)

  • Lim, Hyun-Kyun;Lee, Tae-Ho;Lee, Jae-Hyun;Youm, Jeong-Rok;Song, Jin-Ho;Han, Sang-Beom
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.2
    • /
    • pp.135-142
    • /
    • 2008
  • The present study describes the evaluation of the bioequivalence of two atorvastatin tablets, Lipitor $Tablet^{(R)}$ (Pfizer, reference drug) and Atorva $Tablet^{(R)}$ (Yuhan, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Forty-nine healthy male Korean volunteers received each medicine at the atorvastatin dose of 40 mg in a $2{\times}2$ crossover study with a two weeks washout interval. After drug administration, serial blood samples were collected at a specific time interval from 0-48 hours. The plasma atorvastatin concentrations were monitored by an high performance liquid chromatography -tandem mass spectrometer (LC-MS/MS) employing electrospray ionization technique and operating in multiple reaction monitoring (MRM) and positive ion mode. The total chromatographic run time was 4.5 min and calibration curves were linear over the concentration range of 0.1-100 ng/mL for atorvastatin. The method was validated for selectivity, sensitivity, linearity, accuracy and precision. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48hr) was calculated by the linear log trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were complied trom the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for Atorva $Tablet^{(R)}$ / Lipitor $Tablet^{(R)}$ were ${\log}\;0.9413{\sim}{\log}\;1.0179$ and ${\log}\;0.831{\sim}{\log}\;1.0569$, respectively. These values were within the acceptable bioequivalence intervals of ${\log}\;0.8{\sim}{\log}\;1.25$. Based on these statistical considerations, it was concluded that the test drug, Atorva $Tablet^{(R)}$ was bioequivalent to the reference drug, Lipitor $Tablet^{(R)}$.

ICT based Wireless Power Transmission System Development (ICT 기반의 무선전력전송 시스템 개발)

  • Lee, Jong-Hee;Bang, Junho;Chun, Hyun-Jun;Seo, Beom-Geun;Ryu, In-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.5
    • /
    • pp.67-73
    • /
    • 2016
  • Recently, wireless power transmission has attracted much interest and is the subject of much research in industry and academia. As its name implies, it is a technology which involves transferring power without wires. This paper presents the design of an ICT-based wireless power transmission system. The proposed system consists of a wireless transceiver unit and high-efficiency coil unit, which can increase both the transmission efficiency and the effective power distance. In particular, the wireless transceiver unit was designed to work with the ICT technique to enable real-time remote monitoring. Also, studies were done relating to the effect of reducing the standby power. The optimal frequency of IGBT devices used in industrial wireless power systems of 20[KHz] was utilized. The values of $23.9[{\mu}H]$ and $2.64[{\mu}F]$ were selected for L and C, respectively, through many field experiments designed to optimize the system design. In addition, an output current controlling algorithm was developed for the purpose of reducing the standby power. The results presented in this paper represent a 75[%] to 85[%] higher power transmission efficiency with a 10[%] increase in the effective power transmission distance compared with the existing systems. As a result, the proposed system exhibits a lower standby power and maintenance costs. Also, the designed wireless transceiver unit facilitates fault detection by means of user acquired data with the development of the ICT applied program.

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 무선 센서네트워크 환경구축을 위한 무선 스펙트럼 분석 및 전송시험에 관한 연구)

  • An, Tea-Ki;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.7
    • /
    • pp.3220-3226
    • /
    • 2011
  • In order to monitor internal risk factors such as fire, terror, etc. on the subway station, the surveillance systems using CCTV and various kinds of sensors have been implemented and recently, introduction of surveillance systems using an advanced IT technology, sensor network technology is tried on several areas. Since 2007, Korean government has made an effort to develop the intelligent surveillance and monitoring system, which can monitor fire, intrusion, passenger congestion, health-state of structure, etc., by using wireless sensor network technology and intelligent video analytic technique. For that purpose, this study carried out field wireless communication environment test on Chungmuro Station of Seoul Metro on the basis of ZigBee that is considered as a representative wireless sensor network before field application of the intelligent integrated surveillance system being developed, arranged and analyzed and ZigBee based wireless communication environment test results on the platform and waiting room of Chungmuro Station on this paper. Results of wireless spectrum analysis on the platform and waiting room showed that there is no radio frequency overlapped with that of ZigBee based sensor network and no frequency interference with adjacent frequencies separated 10MHz or more. As results of wireless data transmission test using ZigBee showed that data transmission is influenced by multi-path fading effect from the number and flow rate of passengers on the platform or the waiting room rather than effects from entrance and exit of the train to/from the platform, it should be considered when implementing the intelligent integrated surveillance system on the station.

Effects of Sahyangsohap-won on Cerebral Hemodynamics in Healthy Subjects (사향소합원(麝香蘇合元)이 정상인의 뇌혈류역학에 미치는 영향)

  • Koo, Bon-Soo;Kim, Sung-Hwan;Moon, Sang-Kwan;Cho, Ki-Ho;Kim, Young-Suk;Bae, Hyung-Sup;Lee, Kyung-Sup;Ryu, Soon-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.199-205
    • /
    • 2001
  • Background and Purpose : Transcranial doppler ultrasonography(TCD) is a noninvasive and nonradioactive technique for evaluation of the hemodynamics in large cerebral vessels. Sahyangsohap-won(SS) has been considered to be effective for the treatment of various disease, especially cerebrovascular, cardiovascular, and psychosomatoform disorders. But, there is no study about the effect of SS on the cerebral hemodynamics in humans. The aim of this study was to assess the effect of SS on the changes in cerebral hemodynamics and the dose-dependant effect by using TCD. Subjects and Methods : 30 healthy subjects were randomly divided into three group: group 1 took no drug, group 2 took SS one pill, and group 3 took SS 2 pills. Changes in the mean blood flow velocity(MBFV) and pulsatility index(PI) in the middle cerebral artery were evaluated by means of TCD. We obtained hypercapnia with breath-holding and evaluated cerebrovascular reactivity with the breath-holding index(BHI). Systolic blood pressure(SBP), diastolic blood pressure(DBP), and heart rate(HR) were measured by means of ambulatory blood pressure monitoring. In group 2 and group 3, the evaluations were performed during the baseline and were repeated at 20, 40, and 60 minutes after SS administration. In group 1, the evaluation was performed at corresponding time intervals. Results : In mean values of MSFV, PI, SSP, DBP, and HR, no stastically significant differences were found between the 3 groups. However, BHI values were significantly lower in groups 2 and 3 than in group 1 at 40 minutes after SS administration(P<0.05, group 1 vs group 2, group 1 vs group 3 by post-hoc analysis: Scheffe's test) but in dose-dependant effect, there was no difference between group 2 and group 3. Conclusion : These results suggest that SS can decrease vascular resistance in cerebral small arteries or arterioles and enhance their distensibility. Further studies on larger numbers of subjects are needed to confirm these effects and the dose-dependant effects.

  • PDF

A Study on the Control System of Maximum Demand Power Using Neural Network and Fuzzy Logic (신경망과 퍼지논리를 이용한 최대수요전력 제어시스템에 관한연구)

  • 조성원
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.9 no.4
    • /
    • pp.420-425
    • /
    • 1999
  • The maximum demand controller is an electrical equipment installed at the consumer side of power system for monitoring the electrical energy consumed during every integrating period and preventing the target maximum demand (MD) being exceeded by disconnecting sheddable loads. By avoiding the peak loads and spreading the energy requirement the controller contributes to maximizing the utility factor of the generator systems. It results in not only saving the energy but also reducing the budget for constructing the natural base facilities by keeping thc number of generating plants ~ninimumT. he conventional MD controllers often bring about the large number of control actions during the every inteyating period and/or undesirable loaddisconnecting operations during the beginning stage of the integrating period. These make the users aviod the MD controllers. In this paper. fuzzy control technique is used to get around the disadvantages of the conventional MD control system. The proposed MD controller consists of the predictor module and the fuzzy MD control module. The proposed forecasting method uses the SOFM neural network model, differently from time series analysis, and thus it has inherent advantages of neural network such as parallel processing, generalization and robustness. The MD fuzzy controller determines the sensitivity of control action based on the time closed to the end of the integrating period and the urgency of the load interrupting action along the predicted demand reaching the target. The experimental results show that the proposed method has more accurate forecastinglcontrol performance than the previous methods.

  • PDF

Fabrication and optical characteristics of 50 ㎓ narrow band pass filter for fiber optical communication using dual ion beam sputtering technique (이중 이온빔 스퍼터링 방식을 사용한 채널 간격 50 ㎓ 광통신용 협대역 투과 필터의 제작 및 특성)

  • 김회경;김명진
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.331-337
    • /
    • 2003
  • This paper represents 50 ㎓ narrow band pass filters for fiber optical communication fabricated by dual ion beam sputtering method. We have analyzed the characteristics of the TA$_2$ $O_{5}$ and $SiO_2$ single layers in order to optimize the process conditions for the 50 ㎓ narrow band pass filters, and controlled the film thickness uniformity to less than 0.1 nm deviation by dual peak spike filter pre-deposition. We designed and fabricated 50 ㎓ narrow band pass filters that consist of 216 layers including 4 cavities based on quarter wave optical thickness. Class substrates with high thermal expansion coefficients were used to reduce the film stress. Anti-reflection coating at the rear side of the substrate was also needed to reduce the optical thickness errors of the Optical Monitoring System caused by multiple beam interference between the front side and the rear side of substrate. The optical characteristics of this 50 ㎓ narrow band pass filters are insertion loss of 0.40 ㏈, pass band ripple of 0.20 ㏈, and pass bandwidth at -0.5 ㏈ of 0.20 nm. and isolation bandwidth at -25 ㏈ of 0.6 nm, which satisfy specifications of dense WDM system in fiber optical communications.tions.

3D Thermo-Spatial Modeling Using Drone Thermal Infrared Images (드론 열적외선 영상을 이용한 3차원 열공간 모델링)

  • Shin, Young Ha;Sohn, Kyung Wahn;Lim, SooBong;Lee, Dong-Cheon
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.4
    • /
    • pp.223-233
    • /
    • 2021
  • Systematic and continuous monitoring and management of the energy consumption of buildings are important for estimating building energy efficiency, and ultimately aim to cope with climate change and establish effective policies for environment, and energy supply and demand policies. Globally, buildings consume 36% of total energy and account for 39% of carbon dioxide emissions. The purpose of this study is to generate three-dimensional thermo-spatial building models with photogrammetric technique using drone TIR (Thermal Infrared) images to measure the temperature emitted from a building, that is essential for the building energy rating system. The aerial triangulation was performed with both optical and TIR images taken from the sensor mounted on the drone, and the accuracy of the models was analyzed. In addition, the thermo-spatial models of temperature distribution of the buildings in three-dimension were visualized. Although shape of the objects 3D building modeling is relatively inaccurate as the spatial and radiometric resolution of the TIR images are lower than that of optical images, TIR imagery could be used effectively to measure the thermal energy of the buildings based on spatial information. This paper could be meaningful to present extension of photogrammetry to various application. The energy consumption could be quantitatively estimated using the temperature emitted from the individual buildings that eventually would be uses as essential information for building energy efficiency rating system.

Sternal Retraction and Subclavian Vein Catheter Occlusion during Cardiac Surgery

  • Tarbiat, Masoud;Bakhshaei, Mohammad Hossein;Derakhshanfar, Amir;Rezaei, Mahmoud;Ghorbanpoor, Manoochehr;Zolhavarieh, Seyed Mohammad
    • Journal of Chest Surgery
    • /
    • v.54 no.5
    • /
    • pp.377-382
    • /
    • 2021
  • Background: Subclavian vein (SV) catheterization is a method for the delivery of fluids, drugs, and blood products, venous blood sampling, and central vein pressure monitoring in cardiac surgery. Catheter occlusion is a serious complication of SV catheterization during cardiac surgery, especially after sternal retractor expansion. Methods: In this observational study, 303 patients who had successful right infraclavicular SV catheterization from September 2019 to April 2020 were enrolled to determine the incidence of catheter occlusion. After catheterization, the lumens of all catheters were checked for the ability to infuse and withdraw blood from the catheter before and after sternal retractor expansion. The patients' characteristics, cannulation approach, on-pump or off-pump technique, occlusion of the catheter and its lumens, and any associated complications were recorded. The data were analyzed using IBM SPSS ver. 22.0 (IBM Corp., Armonk, NY, USA). Results: Of the 303 patients studied, 205 were male (67.7%) and 98 were female (32.3%). Catheter occlusion occurred in 11 patients with on-pump cardiopulmonary bypass (CPB) (227 patients) and 4 patients with off-pump CPB (76 patients) (p=0.863). The incidence of catheter occlusion was 4.95% (15 of 303 patients) with no cases of simultaneous 3-lumen occlusion in a catheter. The most commonly occluded lumen was the distal lumen (57.92%). Simultaneous 2-lumen occlusion occurred in 4 patients. Catheter occlusion was found in 3 of 13 malpositioned catheters (23.07%). Conclusion: The current study showed that malpositioning of the catheter tip was a risk factor for catheter occlusion and that the distal lumen of a triple-lumen catheter was the most commonly occluded lumen.

Assessment of Water Circulation and Hydro-characteristics with LID techniques in urbanized areas (도시지역에 적용된 LID 기법의 강우시 수문특성 및 물순환 평가)

  • Choi, Hyeseon;Hong, Jungsun;Jeon, Minsu;Geronimo, Franz Kevin;Kim, Leehyung
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.191-198
    • /
    • 2019
  • High impervious surfaces increase the surface runoff during rainfall and reduces the underground infiltration thereby leading to water cycle distortion. The distortion of water cycle causes various urban environmental problems such as urban flooding, drought, water pollutant due to non-point pollution runoff, and water ecosystem damage. Climate change intensified seasonal biases in urban rainfall and affected urban microclimate, thereby increasing the intensity and frequency of urban floods and droughts. Low impact development(LID) technology has been applied to various purposes as a technique to reduce urban environmental problems caused by water by restoring the natural water cycle in the city. This study evaluated the contribution of hydrologic characteristics and water cycle recovery after LID application using long-term monitoring results of various LID technology applied in urban areas. Based on the results, the high retention and infiltration rate of the LID facility was found to contribute significantly to peak flow reduction and runoff delay during rainfall. The average runoff reduction effect was more than 60% at the LID facility. The surface area of the LID facility area ratio(SA/CA) was evaluated as an important factor affecting peak flow reduction and runoff delay effect.