• 제목/요약/키워드: monitoring results

검색결과 8,859건 처리시간 0.038초

무선 MEMS 시스템을 이용한 구조물 식별 (System Identification of a Building Structure Using Wireless MEMS System)

  • 김홍진
    • 한국소음진동공학회논문집
    • /
    • 제18권4호
    • /
    • pp.458-464
    • /
    • 2008
  • The structural health monitoring has been gaining more importance in civil engineering areas such as earthquake and wind engineering. The use of health monitoring system can also provide tools for the validation of structural analytical model. However, only few structures such as historical buildings and some important long bridges have been instrumented with structural monitoring system due to high cost of installation, long and complicated installation of system wires. In this paper, the structural monitoring system based on cheap and wireless monitoring system is investigated. The use of advanced technology of micro-electro-mechanical system(MEMS) and wireless communication can reduce system cost and simplify the installation. Further the application of wireless MEMS system can provide enhanced system functionality and due to low noise densities. Identification results are compared to ones using data measured from traditional accelerometers and results indicate that the system identification using wireless MEMS system estimates system parameters accurately.

학령기 아동의 자기보호와 부모감독에 따른 또래관계 및 인지적 자기능력 지각 (The Effects of Self-care and Parental Monitoring on Peer Relations and Perceived Cognitive Self-Competence of School Age Children)

  • 천희영;옥경희;김미해
    • 대한가정학회지
    • /
    • 제39권10호
    • /
    • pp.153-168
    • /
    • 2001
  • The objects of this study were to find out the effects of peer relations and perceived cognitive self-competence according to 1) grade, sex, and self-care, 2) parental social status and monitoring. 429 3rd- and 6th-graders (238 boys and 191 girls) were included as subjects. For measuring variables, RCP, Harter's Perceived Cognitive Self-Competence Rating Scale, and Parental Monitoring Questionnaire based on Crouter et al.(1990) were used. The data were analysed by MANOVA, t-test, and univariate ANOVA. The results were as follows.‘Social-Leadership’of peer relations was influenced by children's grade, grade $\times$ sex effects. 3-way interaction of children's variables and parental monitoring made significant differences in ‘Shy-Isolation’. Children's perceived cognitive self-competence was influenced by their grade and parent's social status. These results confirmed the significant roles of self-care and parental monitoring in children's development.

  • PDF

적외선 고막 체온계를 이용한 피판감시 (Flap Monitoring by Infra-red Thermometer)

  • 곽인수;홍준표
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권1호
    • /
    • pp.82-85
    • /
    • 2004
  • Flap monitoring is important for flap salvage. Although there are many methods to observe the flap, practical methods mostly used are subjective methods. Recording flap surface temperature is one of the objective methods of flap monitoring. We used an infra-red thermometer to simplify monitoring of the flap temperature. 60 groin flaps of SD rats are used in the experiment. Artificial arterial or venous insufficiency was made and the surface temperature was checked and compared with body temperature. In the results, the temperature of the arterial clamped flaps was lower than that of body and the mean difference was $0.3^{\circ}C$ after 20 minutes of clamping. In the vein-clamped flaps, the mean decrease was $0.4^{\circ}C$ after 30 minutes of clamping. The all difference of the temperature between the flaps and body was statistically significant. Our results suggest that flap monitoring by infra-red thermometer is simple, useful and helpful to evaluate the flap status.

  • PDF

An Intelligent bridge with an advanced monitoring system and smart control techniques

  • Miyamoto, Ayaho;Motoshita, Minoru
    • Smart Structures and Systems
    • /
    • 제19권6호
    • /
    • pp.587-599
    • /
    • 2017
  • This paper introduces an approach to the realization of an ICT-based bridge remote monitoring system that enables real-time monitoring and controlled adjustments for unexpected heavy loads and also for damaging earthquakes or typhoons. In this paper, an integrated bridge remote monitoring system called the "Intelligent Bridge", which consists of a stand-alone monitoring system (SMS) and a web-based Internet monitoring system(IMS), was developed for not only bridge maintenance but also as an application for a para-stressing bridge system. To verify the possibility of controlling the actual structural performance of an "Intelligent Bridge", a model 2-span continuous cable-stayed bridge with adjustable cables was constructed. The experimental results demonstrate that the implemented monitoring system supplies detailed and accurate information about bridge behaviour for further evaluation and diagnosis, and it also opens up prospects for future application of a web-based remote system to actually adjust in-service bridges under field conditions.

Real-Time Small Exposed Area $SiO_2$ Films Thickness Monitoring in Plasma Etching Using Plasma Impedance Monitoring with Modified Principal Component Analysis

  • 장해규;남재욱;채희엽
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.320-320
    • /
    • 2013
  • Film thickness monitoring with plasma impedance monitoring (PIM) is demonstrated for small area $SiO_2$ RF plasma etching processes in this work. The chamber conditions were monitored by the impedance signal variation from the I-V monitoring system. Moreover, modified principal component analysis (mPCA) was applied to estimate the $SiO_2$ film thickness. For verification, the PIM was compared with optical emission spectroscopy (OES) signals which are widely used in the semiconductor industry. The results indicated that film thickness can be estimated by 1st principal component (PC) and 2nd PC. Film thickness monitoring of small area $SiO_2$ etching was successfully demonstrated with RF plasma harmonic impedance monitoring and mPCA. We believe that this technique can be potentially applied to plasma etching processes as a sensitive process monitoring tool.

  • PDF

아동의 이해점검 능력에 관한 연구 : 점검기준의 사용과 작업기억 용량과의 관계에서 (A Study of Children's Comprehension Monitoring Ability: Monitoring Standards Preference and Relationship with Working Memory Capacity)

  • 송영주
    • 아동학회지
    • /
    • 제19권1호
    • /
    • pp.117-129
    • /
    • 1998
  • This study was designed to examine children's comprehension monitoring ability. Specifically the purpose of this study was to investigate (1) children's monitoring standards preference according to monitoring ability, and (2) the relationships between comprehension monitoring and working memory capacity. The subjects were 60 children, 30 each in 2nd and 4th grades. To measure comprehension monitoring ability, 7 stories including erroneous sentences were used. Working memory capacity was measured by the Reading Span Test (Lee, 1995). Results showed that (1) the high and low monitoring children were not different in monitoring standard preference, and (2) comprehension monitoring ability was significantly and positively related to working memory capacity.

  • PDF

기계시각을 이용한 고단 직립식 산란계 케이지의 무선 감시시스템 개발 (Development of Wireless Monitoring System for Layers Rearing in Multi-tier Layers Battery by Machine Vision)

  • 임송수;장동일;이승주;소재광
    • Journal of Biosystems Engineering
    • /
    • 제32권3호
    • /
    • pp.173-178
    • /
    • 2007
  • This research was conducted to develop and analyze a wireless monitoring system for judging if sick or dead layers (SDL) exist in multi-tier layers battery (MLB) by machine vision, and to evaluate the performance between a wired monitoring system and it. This study used the AP (Access Point), the RS-285 to RS-232 converter, RS-232 to Ethernet converter, PICBASIC board and upgraded lump image processing method to change wired monitoring system into wireless monitoring system. The system was tested at a pilot farm and farm layer house. Results showed that monitoring judgement success rate at a pilot farm on normal cage (without SDL) was 82.3% and that on abnormal cage (with SDL) was 87.5%, respectively. And communication performance test results showed at farm layer house was $700{\sim}900$ kbps while equipments operated. There were dropped slightly than performance of wired monitoring system, however, the quantity was too small to make a significant difference of performance of the controling system developed for wireless communication.

비교 측정을 통한 PM-10 질량농도의 오차 분석 (Analysis of Measurement Error for PM-10 Mass Concentration by Inter-Comparison Study)

  • 정창훈;조용성;황승만;정용국;유재천;신동석
    • 한국대기환경학회지
    • /
    • 제23권6호
    • /
    • pp.689-698
    • /
    • 2007
  • Particular attention is paid to the validity of PM-10 measurement using beta attenuation method. In this study, the inter-comparison studies were undertaken for PM-10 sampler with different measuring methods. The three beta attenuation monitoring instruments (BAM1020, FH C-14, and DIGS-150) and filter based gravitational method using High Volume Air Sampler were collocated and mass concentrations were compared from August to November, 2006. The results of the investigation show that beta attenuation monitoring instruments are comparable with gravitational method within 10% of measurement error. For specific conditions under high humidity and high concentrations, the inter-comparison results also showed a relatively good agreement and this can be explained as the effect of inlet heating of beta attenuation instrument. Subsequently, this study shows that beta attenuation monitoring instruments can be equivalently used with reasonable validity when compared gravimetric method.

Effects of Self-Checked Monitoring Home Exercises on Gait, Balance, Strength, and Activities of Daily Living in People with Parkinson's Disease

  • Lim, Chaegil
    • 국제물리치료학회지
    • /
    • 제11권1호
    • /
    • pp.1940-1949
    • /
    • 2020
  • Background: Self-checked monitoring home exercises are recommended for preventing falls among people with Parkinson's disease. However, as these home exercises are performed autonomously by patients without professional management, their accuracy and efficiency can be compromised. Objective: To investigate the effects of providing regular training sessions to patients and caregivers and of patient self-monitoring of exercise performance following the implementation of a self-checked monitoring exercise program for people with Parkinson's disease. Design: Randomized Pretest-Posttest Control Group Design. Methods: We provided regular self-checked monitoring home exercise and general home exercise programs to 30 participants for 12 weeks. Once a month at the first, fifth, and ninth-week sessions, a rehabilitation team attended the Parkinson's group education. In addition to the subject in the experimental group perform the home exercises program to provide feedback regarding the home exercises program and to carry out a self-monitoring checklist performance for 12 weeks. Results: The 10 m walk test, functional reach test, and sit to stand test and the modified Barthel index significantly improved in the self-checked monitoring home exercise group. Conclusion: These results suggest that self-checked home exercise programs, which facilitate safety and consistent performance of exercises at home, are beneficial for people with Parkinson's disease.

국내 작업환경측정기관의 측정 및 분석장비 보유실태에 대한 고찰 (II) (Evaluation of the Possession of Measurement and Analytical Instruments in Domestic Work Environment Monitoring Service Providers (II))

  • 장재길
    • 한국산업보건학회지
    • /
    • 제24권2호
    • /
    • pp.182-192
    • /
    • 2014
  • Objectives: The aim of this study is to analyze the current status of possession of measurement and analytical instruments at work environment monitoring organizations and their relationships with human resources, including the number of professional engineers and evaluation scores resulting from evaluation programs in 2012. Materials: Data for measurement and analytical instruments were gathered by inspectors who had been assigned by the Korea Occupational Safety and Health Agency(KOSHA) and the Ministry of Employment and Labor(MoEL) during the evaluation program for 2012. Data for 11 monitoring instruments and nice pieces of analytical equipment were collected from 103 organizations. Additional data such as the type of service provides and the number of professional engineers employed were also recorded by the inspectors. Evaluation scores could be acquired from KOSHA. Results: Comprehensive Occupational Health Service Providers showed good operation quality, while University or Hospital Subsidiary and Work Environment Monitoring Organizations recorded relatively poor results. Evaluation scores correlated well with the possession of measurement instruments and human resources for each organization. High yields provided by professional engineers also showed statistically-associated contributions to evaluation scores and monitoring instrument possession. Compared with monitoring instruments, the amount of analytical equipment had little positive impact on organizations' competence. Conclusions: The evaluation results for domestic monitoring organizations revealed that human resources, possession of instruments, and the quality of employees were critical factors for operating the corporations. Each organization should give considerable effort to improving their ability to strengtheninternal quality, resulting in high-yield production for workers and employers by providing improved workplace monitoring services.