• Title/Summary/Keyword: monitoring results

Search Result 8,898, Processing Time 0.051 seconds

PD Monitoring of Transformer Using UHF Technique (UHF 기술을 응용한 전력용 변압기의 PD 모니터링)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2116-2117
    • /
    • 2008
  • This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Structural Health Monitoring by using the Time-Reversal and STFT (탄성파의 시간-역전현상과 STFT 를 이용한 구조물 손상진단)

  • Go, Han-Suk;Lee, U-Sik
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2066-2072
    • /
    • 2008
  • The time reversal was investigated for direct root between PZT and PZT, but in case of a circular PZT, lamb wave moves not only along the direct root but also another roots. The center frequency of lamb wave is kept when the lamb waves are reflected from damage. This paper presents experimental and theoretical results for the new structural health monitoring method by above features of lamb wave, and we can increase accuracy of the new structural health monitoring method by using STFT(Short Time Fourier Transform).

  • PDF

On the Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템용 검교정기 제작 및 실험)

  • 박준오;이준석;최일윤
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1053-1058
    • /
    • 2002
  • Calibration of the health monitoring system is considered in this study. For this, brief introduction on the realtime monitoring system, installed in some of the Korea Highspeed Railway bridges, is made and specifications of the calibrators are outlined. Calibration method is next explained for each sensor and detailed procedures are illustrated. Calibration results will be published elsewhere and modification of the gauge factors will also be investigated in detail.

  • PDF

The Development of Distribution Transformer Remote Monitoring System using CATV Cable (CATV회선을 이용한 배전용 변압기 부하의 원격감시시스템 개발)

  • Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.939-942
    • /
    • 1998
  • This paper presents the process on the construction for the remote distribution pole transformer monitoring system. Especially, this system uses CATV cable as communication media which is located in KEPCO's main distribution line. It has four major components such as sensor for measuring secondary voltage and currents of distribution transformer, RF modem for data modulating/de-modulating, communication media for sending/receiving of data, and pc server for monitoring the results of sensing or computing information. This paper also describes the configuration of these each component's configuration and its functions.

  • PDF

Usefulness of External Monitoring Flap in the Buried Jejunal Free Flap (유리 공장 피판술 후 외부 감시 피판의 유용성)

  • Kim, Baek Kyu;Chang, Hak;Minn, Kyung Won;Hong, Joon Pio;Koh, Kyung Suck
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.432-435
    • /
    • 2007
  • Purpose: The jejunal free flap has the shorter ischemic time than other flap and requires a laparotomy to harvest it. As the evaluation of the perfusion the buried flap is very important, the perfusion of the buried jejunal free flap requires monitoring for its salvage. We tried to improve the monitoring flap method in the jejunal free flap and examined its usefulness. Methods: From March 2002 to March 2006, the monitoring flap method was applied to 4 cases in 8 jejunal free flaps for the pharyngeal and cervical esophageal reconstructions. The distal part of the jejunal flap was exposed without suture fixation through cervical wound for monitoring its perfusion. The status of perfusion was judged by the color change of jejunal mucosa and mesentery. If necessary, pin prick test was performed. Doppler sonography was applied to mesenteric pedicle of the monitoring flap in case of suspicious abnormal circulation. Results: The monitoring flap shows no change in 3 cases, but the congestion happened in one case at the 12 hours after the operation. This congestion was caused by the twisting or kinking of the mesenteric pedicle of the monitoring flap. So, we fixed up the monitoring flap close to adjacent cervical skin for prevention of rotation. Finally, the main part of transferred jejunal flap was intact. Conclusion: The success of a jejunal free flap depends on close postoperative monitoring and early detection of vascular compromise. So, various monitoring methods have been tried, for instance, direct visualization using a fiberoptic pharyngoscope, through a Silastic window placed in the neck flap, or external surface monitoring with an Doppler sonography, use of a buried monitoring probe. But, all of the above have their own shortcomings of simplicity, non-invasiveness, reliability and etc. In our experience, monitoring flap can be a accurate and reliable method.

The Importance of Monitoring Wells Maintenance in Improving Groundwater Quality (지하수 관측정의 시설개선에 따른 수질변화와 유지관리에 대한 연구)

  • Kim, Jeong-Woo;Seo, Yongkyo;Kim, Rak-Hyeon;Cheon, Jeong-Yong
    • The Journal of Engineering Geology
    • /
    • v.24 no.2
    • /
    • pp.283-295
    • /
    • 2014
  • Groundwater monitoring wells are important to maintain their performance for long term monitoring. The monitoring wells with extensive internal incrustation by clay adsorption were selected for this study. The performance of these monitoring wells was improved by pump washing, tube replacements for dedicated samplers, and well surging. After each improvement, the Mg, Mn, and Zn concentrations were increased. The results show that under these conditions, the monitoring wells must be carefully inspected at least once a year. Even in the case of no abnormal phenomenon like as internal incrustation, the monitoring wells need to be serviced at least once every four to five years to guarantee that they are effectively monitoring groundwater quality.

Design of ICT-based Agricultural Safety Monitoring System Models

  • Kim, Insoo;Lee, Kyung-Suk;Chae, Hye-Seon;Seo, Min-Tea
    • Journal of the Ergonomics Society of Korea
    • /
    • v.35 no.4
    • /
    • pp.193-204
    • /
    • 2016
  • Objective: This study carried out base research to build an agricultural safety monitoring system through ICT convergence to reduce safety accidents and enhance welfare in life in the agricultural field. Background: The functions and values of rural villages as the space of living are recognized anew, but occupational accident rate due to farm work accidents is on the rise each year. Therefore, the seriousness of such a problem emerges. The convergence technology combining ICT is recently applied to industries overall, and therefore better services are offered. However, studies on ICT convergence has not yet been applied to the agricultural safety field. Method: This study identified ICT convergence service technology trends and representative serious accident types mainly occurring in agricultural activities. This study defined the major factors of farm work accidents and ICT to solve those accident factors including the sensor technology, wired/wireless communication technology and location information service, and applied them to prototype PCB for the development of an agricultural safety monitoring system. Results: This study proposed an emergency monitoring system for farmers and a harmful environment monitoring system. The ICT technology to prevent farm work accidents can be summarized as sensing technology, ICT and network technology and user interface technology. This study also designed PCB module configuration and situation judgment algorithm as basic research for proposed monitoring system development. Conclusion: The ICT-based agricultural safety monitoring research proposed in this study is expected to become the basis to build a future real time monitoring system, and also is expected to contribute to social safety and welfare service improvement for farmers. Application: The ICT convergence farmer accident prevention system will make contributions to the prevention of serious farm work accidents.

Implementation of Remote Monitoring Scenario using CDMA Short Message Service for Protected Crop Production Environment

  • Bae, Keun-Soo;Chung, Sun-Ok;Kim, Ki-Dae;Hur, Seung-Oh;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.36 no.4
    • /
    • pp.279-284
    • /
    • 2011
  • Protected vegetable production area is greater than 26% of the total vegetable production area in Korea, and portion of protected production area is increasing for flowers and fruits. To secure stable productivity and profitability, continuous and intensive monitoring and control of protected crop production environment is critical, which is labor- and time-consuming. Failure to maintain proper environmental conditions (e.g., light, temperature, humidity) leads to significant damage to crop growth and quality, therefore farmers should visit or be present close to the production area. To overcome these problems, application of remote monitoring and control of crop production environment has been increasing. Wireless monitoring and control systems have used CDMA, internet, and smart phone communications. Levels of technology adoption are different for farmers' needs for their cropping systems. In this paper, potential of wireless remote monitoring of protected agricultural environment using CDMA SMS text messages was reported. Monitoring variables were outside weather (precipitation, wind direction and velocity, temperature, and humidity), inside ambient condition (temperature, humidity, $CO_2$ level, and light intensity), irrigation status (irrigation flow rate and pressure), and soil condition (volumetric water content and matric potential). Scenarios and data formats for environment monitoring were devised, tested, and compared. Results of this study would provide useful information for adoption of wireless remote monitoring techniques by farmers.

Study on the Optimal Location Selection for Environmental Noise Monitoring Systems (환경소음측정망 최적 위치선정에 관한 연구)

  • Shin, Sangmun;Won, Jeongwoo;Kim, Hwail
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1307-1320
    • /
    • 2014
  • A number of problems associated with environmental noises in urban areas have significantly been considered. Specific measurement and estimation of the environmental noise became a primary issue in local governments. Environmental noise monitoring system is required in order to estimate and verify the a city noise map. However, current monitoring positions may not perfectly represent and incorporate many different view points, such as districts of a city, different utilizations of a city by the law, populations, and classifications and traffics of roads. In addition, scientific method to provide specific noise monitoring positions my not be avaliable in current literature. For this reason, the primary objective of this paper is to propose a new method for introducing a number of monitoring positions in the entire city. First, the quality function deployment (QFD) method was utilized to simultaneously represent both districts and utilizations of a city. Second, a new algorithm to find a number of monitoring positions was proposed by compromising many different view points: populations, classifications of roads and areas, and traffics of roads. Finally, the proposed monitoring positions and a sample noise map was provided for verification purposes. Based on these results, the proposed algorithm including the QFD concept may successfully provide specific noise monitoring positions by simultaneously consider may different view points and requirements of a city.

Assessment of The Priority Order of Monitoring Devices on Maintenance for The Long-Term Safety of Existing Fill Dam (기존 필댐 장기간 안전관리를 위한 계측항목 유지보수 우선순위 산정)

  • Lee, Jongwook;Jeon, Jaesung;Lim, Heuidae
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.67-79
    • /
    • 2009
  • Although readjustment of monitoring system for existing fill dam maintenance is needed by the sustainable increasing of the abandonment rate of monitoring devices by malfunction through the life-cycle of dam, monitoring plans for long-term dam safety has relied on the experience and the opinion of minor expert group without systematic and quantitative analysis on the failure modes and the priority order of monitoring devices on maintenance. In this study the priority order of monitoring devices of existing 5 fill dams was evaluated quantitatively based on the preceding study (Andersen et al, 1999) and the result recommended the establishment of real-time monitoring system for seepage, pore pressure and crest settlement as the readjustment plan for existing fill dam monitoring system. This readjustment plan matches well with the recommendation of PWRI (1984), JCOLD (1986) and the results from Bagherzadeh-Khakkahali and Mirghasemi (2005).

  • PDF