• Title/Summary/Keyword: monitoring results

Search Result 8,859, Processing Time 0.046 seconds

A Study on Optimal Sensor Placement Using Sensitivity Analysis (민감도 해석을 이용한 센서의 최적 위치 선정에 관한 연구)

  • Son, In-Soo;Lee, Doo-Ho
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.3
    • /
    • pp.241-247
    • /
    • 2011
  • Although intensive development continues on innovative sensor systems, there is still considerable uncertainty in deciding on the number of sensors required and their locations in order to obtain adequate information on structural behavior. This paper is concerned with the sensor locations on a beam-structure for prognostic structural health monitoring. The purpose of this study is to investigate how to determine optimal sensor placement(OSP) from the sensitivity information of a known failure mode. The sensitivity of the forced vibration response of a beam to the variation of stiffness due to a crack is calculated analytically and used to determine the optimal sensor locations for the specified failure mode. The results of this method compared with the results of different OSP methods. The results have shown that the proposed method on optimal sensor placement is very effective in structural health monitoring.

Improving National Curriculum Monitoring System (국가 교육과정 모니터링 체제 개선 연구)

  • Lee, Keunho;Lee, Byeongcheon;Ka, Euna;Lee, Jooyoun
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.2
    • /
    • pp.588-599
    • /
    • 2016
  • This study aims to provide suggestions for improving national curriculum monitoring system. To achieve this goal, we analyzed the Korean national curriculum monitoring system in terms of actual problems and challenges faced by school teachers, and drew criteria for analyzing overseas curriculum monitoring system. Based on the criteria, we investigated the Australian and Singaporean national curriculum monitoring system. We especially carried out interviews with school teachers, principals, officials in Ministry of Education, and tried to identify the actual condition of curriculum monitoring system beyond superficial investigation of them. The results of this study provide four suggestions such as integrated way of monitoring, multi-way open system, and substantial approach into monitoring operation which will lead into meeting with the purpose of the monitoring system of national curriculum.

Suggestions on the Selection Method of Priority Monitoring Sites for Hazardous Air Pollutants in Megacities (유해대기오염물질 모니터링을 위한 대도시 우선순위 측정지점 선정기법 제안)

  • Kwon, Hye-Ok;Kim, Seong-Joon;Kim, Yong Pyo;Kim, Sang-Kyun;Hong, Ji-Hyung;Choi, Sung-Deuk
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.544-553
    • /
    • 2017
  • There is an overall guideline of the installation of air quality monitoring stations in Korea, but specified steps for the selection of monitoring sites for hazardous air pollutants(HAPs) are not provided. In this study, we proposed a systematic method for the selection of monitoring sites for HAPs using geographic information system (GIS). As a case study, the Seoul metropolitan area (Seoul, Incheon, and Gyeonggi Province) was chosen, and 15 factors including population, vehicle registration, and emission data were compiled for each grid cell ($7km{\times}7km$). The number of factors above the top 30% of individual data for each grid cell was used to select priority monitoring sites for HAPs. In addition, several background sites were added for data comparison and source identification. Three scenarios were suggested: Scenario 1 with 7 sites, Scenario 2 with 17 sites, and Scenario 3 with 30 sites. This proposal is not the final result for an intensive monitoring program, but it is an example of method development for selecting appropriate sampling sites. These results can be applied not only to HAPs monitoring in megacities but also to the national HAPs monitoring network.

Guidelines for Transcatheter Aortic Valve Replacement in Korea: Past Obstacles and Future Perspectives

  • Choo, Suk Jung;Shinn, Sung Ho;Kim, Kyung Hwan;Kim, Wook Sung;Oh, Sam-Sae;Lee, Sak
    • Journal of Chest Surgery
    • /
    • v.51 no.4
    • /
    • pp.231-240
    • /
    • 2018
  • Background: Analyses of the efficacy and safety of transcatheter aortic valve replacement (TAVR) in most countries have been based on outcomes obtained in accordance with national practice guidelines and monitoring protocols. The purpose of this study is to share our experience regarding the process for establishing guidelines and monitoring protocols for the use of TAVR in Korea, in the hopes that it may be helpful to others undergoing a similar process in their own country. Methods: The Korean guidelines for TAVR were established on June 1, 2015 in through a tri-party agreement involving the Department of Health and Welfare, the Korean Society of Thoracic and Cardiovascular Surgery and the Korean Society of Cardiology. We agreed to monitor the guidelines transparently and to exchange opinions regarding amendments or continuation of its contents after 3 years of monitoring. Results: The monitoring meetings were not held as regularly as agreed, and monitoring was also made difficult by insufficient and incomplete data. Nevertheless, during the meetings, measures to improve the monitoring process were discussed, and accordingly, an agreement was made to continue the monitoring process, with the aim of completing data collection by 2018. Conclusion: Compliance with guidelines is critical for assessing the efficacy and safety of TAVR. Moreover, the TAVR monitoring process must be properly conducted for an accurate evaluation to be made. Any country planning to introduce TAVR may encounter difficulties with regards to the optimal initiation strategy and subsequent monitoring. Nevertheless, continued efforts should be made to persuade the government and the corresponding medical societies to facilitate the optimal application of TAVR.

Design of Stack Monitoring System with Improved Performance (성능이 향상된 Stack Monitoring System의 설계)

  • Jang, Kyeong-Uk;Lee, Joo-Hyun;Lee, Seong-Won;Lee, Seung-Ho
    • Journal of IKEEE
    • /
    • v.20 no.3
    • /
    • pp.299-302
    • /
    • 2016
  • In this paper, we designed the stack monitoring system with improved performance. To block the incoming pulse noise to the amplifier, shield and the power supply impedance are reduced and the power circuit is isolated. The control unit is developed with variable high voltage, adaptive gain, offset and threshold in order to match the scintillation detector characteristic to the apparatus. 300-1500V variable high voltage power circuit is configured applicable to various scintillation detector. Stack monitoring system with improved performance guarantee the efficiency and the reliability by considering the characteristic of various scintillation detector. Developed stack monitoring system is evaluated with certified testing equipment and shows excellent performance with respect to the uncertainty of the sensor test results.

Development of Diagnostic and Monitoring Method for Concrete Structure Using AE (AE를 이용한 콘크리트 구조물 진단 및 감시 방법의 개발)

  • 최기상;최기홍
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.146-154
    • /
    • 1999
  • The feasibility of using AE for monitoring mechanical failure in concrete structures has been tested. Specifically, the relationship between the fracture and the characteristics of AE signal is theoretically and experimentally investigated. The experimental results manifest that the high sensitivity of AE signal to the fracture of concrete structure makes it a good choice as sensor for monitoring concrete structure.

  • PDF

PD Monitoring of Transformer Using UHF Technique (UHF 기술을 응용한 전력용 변압기의 PD 모니터링)

  • Choi, Yong-Sung;Hwang, Jong-Sun;Lee, Kyung-Sup
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2116-2117
    • /
    • 2008
  • This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

  • PDF

Structural Health Monitoring by using the Time-Reversal and STFT (탄성파의 시간-역전현상과 STFT 를 이용한 구조물 손상진단)

  • Go, Han-Suk;Lee, U-Sik
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.2066-2072
    • /
    • 2008
  • The time reversal was investigated for direct root between PZT and PZT, but in case of a circular PZT, lamb wave moves not only along the direct root but also another roots. The center frequency of lamb wave is kept when the lamb waves are reflected from damage. This paper presents experimental and theoretical results for the new structural health monitoring method by above features of lamb wave, and we can increase accuracy of the new structural health monitoring method by using STFT(Short Time Fourier Transform).

  • PDF

On the Calibration of Health Monitoring System installed in the Railway Bridges (철도교 상시계측시스템용 검교정기 제작 및 실험)

  • 박준오;이준석;최일윤
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.1053-1058
    • /
    • 2002
  • Calibration of the health monitoring system is considered in this study. For this, brief introduction on the realtime monitoring system, installed in some of the Korea Highspeed Railway bridges, is made and specifications of the calibrators are outlined. Calibration method is next explained for each sensor and detailed procedures are illustrated. Calibration results will be published elsewhere and modification of the gauge factors will also be investigated in detail.

  • PDF

The Development of Distribution Transformer Remote Monitoring System using CATV Cable (CATV회선을 이용한 배전용 변압기 부하의 원격감시시스템 개발)

  • Park, Chang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.939-942
    • /
    • 1998
  • This paper presents the process on the construction for the remote distribution pole transformer monitoring system. Especially, this system uses CATV cable as communication media which is located in KEPCO's main distribution line. It has four major components such as sensor for measuring secondary voltage and currents of distribution transformer, RF modem for data modulating/de-modulating, communication media for sending/receiving of data, and pc server for monitoring the results of sensing or computing information. This paper also describes the configuration of these each component's configuration and its functions.

  • PDF