• Title/Summary/Keyword: monitoring method

Search Result 6,743, Processing Time 0.037 seconds

Case Study on Technology and Regulation Improvement of Subway Maintenance Monitoring (지하철 유지관리 계측의 기술 및 제도 개선방안 연구)

  • 우종태;김홍석
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.303-308
    • /
    • 2000
  • By means of analyzing of monitoring technology and monitoring regulation based on maintenance monitoring system installed in subway tunnel section, it needs monitoring system, development of operating program, monitoring analyzing system and development of analysis method, establishment of maintenance monitoring standard specification, and performance of responsible monitoring supervision for applying to subway monitoring maintenance effectively in future. It requires specialized monitoring and legislation of monitoring subcontract, improvement of monitoring work contract method, establishment the standard payment of monitoring, and effective calibration and correction of monitoring system in the plan of improving monitoring regulation.

  • PDF

Diagrammatic Representation of Environmental Monitoring Data

  • Yoshioka, Takahito;Sekino, Tatsuki
    • Korean Journal of Ecology and Environment
    • /
    • v.38 no.spc
    • /
    • pp.76-83
    • /
    • 2005
  • The marked increase in the number of environmental problems, combined with the increase in their intensity and spatial extent, has resulted in an ever-increasing need for constant monitoring. This is complicated by the occurrence of new and complicated environmental issues that often prevent a thorough understanding of the entire monitoring framework. In the present study, a diagrammatic method was developed to present the entire framework of a monitoring plan. The diagram was separated into three sections- "Problem Section", "Research Process and Data Section" and "Entities Section" - to clearly present the disparate relationships between monitoring objectives and the monitoring procedure. Notation of the diagrams was undertaken using Unified Modeling Language (UML). A hypothetical monitoring plan for an environmental problem was designed to assess usefulness of the diagrammatic method. The diagram was capable of reviewing and revising the monitoring plan and could be used to select a monitoring procedure according to the monitoring objectives of the plan. The results suggested that this diagrammatic method was effective for designing an appropriate monitoring plan for a given monitoring objective.

Force monitoring of Galfan cables in a long-span cable-truss string-support system based on the magnetic flux method

  • Yuxin Zhang;Xiang Tian;Juwei Xia;Hexin Zhang
    • Structural Monitoring and Maintenance
    • /
    • v.10 no.3
    • /
    • pp.261-281
    • /
    • 2023
  • Magnetic flux sensors are commonly used in monitoring the cable force, but the application of the sensors in large diameter non-closed Galfan cables, as those adopted in Yueqing Gymnasium which is located in Yueqing City, Zhejiang Province, China and is the largest span hybrid space structure in the world, is seldom done in engineering. Based on the construction of Yueqing Gymnasium, this paper studies the cable tension monitoring using the magnetic flux method across two stages, namely, the pre-calibration stage before the cable leaves the rigging factory and the field tension formation stage of the cable system. In the pre-calibration stage in the cable factory, a series of 1:1 full-scale comparative tests were carried out to study the feasibility and relability of this kind of monitoring method, and the influence on the monitoring results of charging and discharging voltage, sensor location, cable diameter and fitting method were also studied. Some meaningful conclusions were obtained. On this basis, the real-time cable tension monitoring system of the structure based on the magnetic flux method is established. During the construction process, the monitoring results of the cables are in good agreement with the data of the on-site pressure gauge.The work of this paper will provide a useful reference for cable force monitoring in the construction process of long-span spatial structures.

A Data-Driven Activity Monitoring Method for Abnormal Sales Behavior Detection (이상 판매활동을 탐지하기 위한 데이터 기반 활동 모니터링 기법)

  • Park, Sungho;Kim, Seoung Bum
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.5
    • /
    • pp.492-500
    • /
    • 2014
  • Activity monitoring has been widely recognized as important and critical tools in system monitoring for detection of abnormal behavior. In this research, we propose a data-driven activity monitoring method to measure relative sales performance which is not sensitive to special event which frequently occur in marketing area. Moreover, the proposed method can automatically updates the monitoring threshold that accommodates a drastically changing business environment. The results from simulation and practical case study from sales of electronic devices demonstrate the usefulness and applicability of the proposed activity monitoring method.

A Study on the Distribution Characteristics of Sulfur Compounds in Ambient air using Continuous Monitoring Method in Incheon Area

  • Seo, Seok-Jun;Lim, Yong-Jae;Hong, You-deok;Park, Geon-Young
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.128-134
    • /
    • 2015
  • This paper focuses on the applicability of a continuous monitoring method on trace sulfur compounds in the ambient air by TD and GC/PFPD. The target compounds for monitoring include H2S(hydrogen sulfide), Methyl mercaptan, Dimethyl Sulfide, and Dimethyl disulfide. The result of QA/QC on monitoring instruments satisfies all the standards of Odor Measurement and Analysis Method, showing that the reproductivity of the compounds by concentration is within 10%, linearity is above 0.98 of a correlation efficient, method detection limit is 0.16 ppb by MM standard, and recovery rate is over 70%. Monitoring was conducted for two years from March 2006 to February 2008. As a result of the monitoring, the average concentration of H2S was 0.08 ppb, with the maximum concentration at 16.15 ppb. The result indicates that it is reasonable to do continuous monitoring as there appears a spontaneous event of high concentration by the condition of the site during monitoring odor-causing substances. Therefore, it is suggested that the continuous monitoring method used in this paper is appropriate to identify the characteristics of sudden occurrence and concentration variations of sulfur compounds.

A Study of Multiplex RE Monitoring Method of Low-Price for Stand-Alone PV Power Generation System (독립형 태양광 발전 시스템을 위한 저가의 다중 무선 모니터링 기법에 관한 연구)

  • Oh Jin-Seok;Kwak Jun-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.5
    • /
    • pp.579-586
    • /
    • 2005
  • Recently, it has demanded to the wireless monitoring system in stand-alone PV power generation system. We propose the multiplex monitoring method using RF unit of low-price. RF unit consists of RF modem and communication controller. It is also able to use by repeater to communicate long distance. In this paper. two algorithms were programmed by CCS-C and C++ for multiplex monitoring method, The algorithm of choosing unit was used 'select and poll method' and the course assignment algorithm was embodied with 'Bellman-Ford algorithm'. The good result was achieved in the actual test without communication-data lose. The proposed method will be applied such as monitoring system of PV light on the wayside, monitoring system of unmanned lighthouse, monitoring system of refrigeration container on vessel and so on. It can be applied in the field that various ocean energy system.

Copula entropy and information diffusion theory-based new prediction method for high dam monitoring

  • Zheng, Dongjian;Li, Xiaoqi;Yang, Meng;Su, Huaizhi;Gu, Chongshi
    • Earthquakes and Structures
    • /
    • v.14 no.2
    • /
    • pp.143-153
    • /
    • 2018
  • Correlation among different factors must be considered for selection of influencing factors in safety monitoring of high dam including positive correlation of variables. Therefore, a new factor selection method was constructed based on Copula entropy and mutual information theory, which was deduced and optimized. Considering the small sample size in high dam monitoring and distribution of daily monitoring samples, a computing method that avoids causality of structure as much as possible is needed. The two-dimensional normal information diffusion and fuzzy reasoning of pattern recognition field are based on the weight theory, which avoids complicated causes of the studying structure. Hence, it is used to dam safety monitoring field and simplified, which increases sample information appropriately. Next, a complete system integrating high dam monitoring and uncertainty prediction method was established by combining Copula entropy theory and information diffusion theory. Finally, the proposed method was applied in seepage monitoring of Nuozhadu clay core-wall rockfill dam. Its selection of influencing factors and processing of sample data were compared with different models. Results demonstrated that the proposed method increases the prediction accuracy to some extent.

Internal force monitoring design of long span bridges based on ultimate bearing capacity ratios of structural components

  • Hu, Ke;Xie, Zheng;Wang, Zuo-Cai;Ren, Wei-Xin;Chen, Lei-Ke
    • Structural Monitoring and Maintenance
    • /
    • v.5 no.1
    • /
    • pp.93-110
    • /
    • 2018
  • In order to provide a novel strategy for long-span bridge health monitoring system design, this paper proposes a novel ultimate bearing capacity ratios based bridge internal force monitoring design method. The bridge ultimate bearing capacity analysis theories are briefly described. Then, based on the ultimate bearing capacity of the structural component, the component ultimate bearing capacity ratio, the uniformity of ultimate bearing capacity ratio, and the reference of component ultimate bearing capacity ratio are defined. Based on the defined indices, the high bearing components can then be found, and the internal force monitoring system can be designed. Finally, the proposed method is applied to the bridge health monitoring system design of the second highway bridge of Wuhu Yangtze river. Through the ultimate bearing capacity analysis of the bridge in eight load conditions, the high bearing components are found based on the proposed method. The bridge internal force monitoring system is then preliminary designed. The results show that the proposed method can provide quantitative criteria for sensors layout. The monitoring components based on the proposed method are consistent with the actual failure process of the bridge, and can reduce the monitoring of low bearing components. For the second highway bridge of Wuhu Yangtze river, only 59 components are designed to be monitored their internal forces. Therefore, the bridge internal force monitoring system based on the ultimate bearing capacity ratio can decrease the number of monitored components and the cost of the whole monitoring system.

A sampling and estimation method for monitoring poultry red mite (Dermanyssus gallinae) infestation on caged-layer poultry farms

  • Oh, Sang-Ik;Park, Ki-Tae;Jung, Younghun;Do, Yoon Jung;Choe, Changyong;Cho, Ara;Kim, Suhee;Yoo, Jae Gyu
    • Journal of Veterinary Science
    • /
    • v.21 no.3
    • /
    • pp.41.1-41.12
    • /
    • 2020
  • Background: The poultry red mite, Dermanyssus gallinae, is a serious problem in the laying hen industry worldwide. Currently, the foremost control method for D. gallinae is the implementation of integrated pest management, the effective application of which necessitates a precise monitoring method. Objectives: The aim of the study was to propose an accurate monitoring method with a reliable protocol for caged-layer poultry farms, and to suggest an objective classification for assessing D. gallinae infestation on caged-layer poultry farms according to the number of mites collected using the developed monitoring method. Methods: We compared the numbers of mites collected from corrugated cardboard traps, regarding with length of sampling periods, sampling sites on cage, and sampling positions in farm buildings. The study also compared the mean numbers of mites collected by the developed method with the infestation levels using by the conventional monitoring methods in 37 caged-layer farm buildings. Results: The statistical validation provided the suitable monitoring method that the traps were installed for 2 days on feed boxes at 27 sampling points which included three vertical levels across nine equally divided zones of farms. Using this monitoring method, the D. gallinae infestation level can be assessed objectively on caged-layer poultry farms. Moreover, the method is more sensitive than the conventional method in detecting very small populations of mites. Conclusions: This method can be used to identify the initial stages of D. gallinae infestation in the caged-layer poultry farms, and therefore, will contribute to establishment of effective control strategies for this mite.

An Efficient Monitoring Method of a Network Protocol for Downloadable CAS

  • Jeong, Young-Ho;Kwon, Oh-Yung;Ahn, Chung-Hyun;Hong, Jin-Woo
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2010.07a
    • /
    • pp.32-35
    • /
    • 2010
  • This paper presents an efficient monitoring method of a network protocol for a downloadable conditional access system (DCAS) that can securely transmit conditional access software via a bi-directional communication channel. In order to guarantee a secure channel based on mutual authentication between a DCAS head end server and set-top boxes, DCAS messages are encrypted and digitally signed. Owing to applied cryptographic algorithms, it is impossible to get information from messages directly without additional processing. Through categorizing DCAS messages into several groups, the proposed monitoring method can efficiently parse and trace DCAS messages in real-time. In order to verify the stability and effectiveness of the proposed monitoring method, we implement a DCAS monitoring system capable of capturing and parsing all DCAS messages. The experimental results show that the proposed monitoring method is well designed.

  • PDF