• Title/Summary/Keyword: monitoring device

Search Result 1,398, Processing Time 0.029 seconds

Development and Performance Evaluation of Multiple Sensor for Groundwater Quality Monitoring and Remote Control System using IoT (IoT기반 지하수 수질모니터링을 위한 다중센서모듈 개발 및 성능평가)

  • Chang, Hyunjin;Moon, Boram;Yoon, Seunggyun;Jin, Taeseok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.10
    • /
    • pp.1957-1963
    • /
    • 2017
  • This paper has proposed a new-type groundwater auto-monitoring system based on Multi-Sensor Device. The system adopted Multi-Sensor Device as host computer of data acquisition, used Windows Mobile which was prevalent operation system of Multi-Sensor Device. It adopted serial port CAN and RS485 as the communication interface between goundwater sensor Device and monitor host machine and utilized serial-linked multi-sensor design to measure effectively according to the depth of groundwater. We present a design for a groundwater monitoring system based on a network of wirelessly linked sensors. The proposed solution will enable groundwater researchers and decision makers to have quick access to the groundwater data with less effort and cost. Though our design is initially meant for groundwater monitoring, it can be easily adapted to other fields of environmental monitoring.

A design of Software 2D BitBLT Engine based on RTOS (RTOS 기반의 소프트웨어 2D BitBLT 엔진의 설계)

  • Kim, Bong-Joo;Hong, Jiman
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.4
    • /
    • pp.35-41
    • /
    • 2014
  • In this paper, we proposed the implementation of software-based 2D BitBLT engine on the pSOS operating system and the operation of the BitBLT engine on patient monitoring device was verified. To verify the proposed method on the patient monitoring device, we designed prototype PCB board, and verified the operation. We designed the motherboard by using ARM9-based CPU. Because hardware-based BitBLT module was replaced with software-based one, CPU load problem was weighted. To solve this problem, w changed 400Mhz processor instead of 200Mhz processor. We implemented 2D BitBLT kernel module as a device driver which is one of the key elements of a graphics controller GUI in patient monitoring device.

Development of TPMS Device and Mobile App System for Marine Emergency Notification (해양 응급상황 알림을 위한 TPMS 디바이스와 모바일 앱 시스템 개발)

  • Dong-Hwan Gong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.49-53
    • /
    • 2024
  • Maritime safety is a critical factor in protecting lives from accidents at sea and fostering a safer marine environment. In this study, we developed a TPMS device aimed at enhancing maritime safety, providing technological solutions for detecting accidents at sea and enabling swift responses. The device utilizes a Tube Pressure Monitoring System (TPMS) to detect tube expansion and is designed to collect real-time data and communicate with surrounding devices for rapid responses. Experimental results confirm the effective detection of pressure by TPMS (Tube Pressure Monitoring System) and stable data transmission and reception with the main IoT device. Additionally, a mobile app capable of receiving emergency alert messages and accessing information for rapid responses in emergency situations was developed. The developed device and mobile app encompass technology applicable not only in the maritime safety field but also in various other application areas, with potential for expanded application in real-world scenarios in the future. These results are expected to contribute to enhancing safety in the marine environment.

Summative Usability Assessment of Software for Ventilator Central Monitoring System (인공호흡기 중앙감시시스템 소프트웨어의 사용적합성 총괄평가)

  • Ji-Yong Chung;You Rim Kim;Wonseuk Jang
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.363-376
    • /
    • 2023
  • According to the COVID-19, development of various medical software based on IoT(Internet of Things) was accelerated. Especially, interest in a central software system that can remotely monitor and control ventilators is increasing to solve problems related to the continuous increase in severe COVID-19 patients. Since medical device software is closely related to human life, this study aims to develop central monitoring system that can remotely monitor and control multiple ventilators in compliance with medical device software development standards and to verify performance of system. In addition, to ensure the safety and reliability of this central monitoring system, this study also specifies risk management requirements that can identify hazardous situations and evaluate potential hazards and confirms the implementation of cybersecurity to protect against potential cyber threats, which can have serious consequences for patient safety. As a result, we obtained medical device software manufacturing certificates from MFDS(Ministry of Food and Drug Safety) through technical documents about performance verification, risk management and cybersecurity application.The purpose of this study is to conduct a usability assessment to ensure that ergonomic design has been applied so that the ventilator central monitoring system can improve user satisfaction, efficiency, and safety. The rapid spread of COVID-19, which began in 2019, caused significant damage global medical system. In this situation, the need for a system to monitor multiple patients with ventilators was highlighted as a solution for various problems. Since medical device software is closely related to human life, ensuring their safety and satisfaction is important before their actual deployment in the field. In this study, a total of 21 participants consisting of respiratory staffs conducted usability test according to the use scenarios in the simulated use environment. Nine use scenarios were conducted to derive an average task success rate and opinions on user interface were collected through five-point Likert scale satisfaction evaluation and questionnaire. Participants conducted a total of nine use scenario tasks with an average success rate of 93% and five-point Likert scale satisfaction survey showed a high satisfaction result of 4.7 points on average. Users evaluated that the device would be useful for effectively managing multiple patients with ventilators. However, improvements are required for interfaces associated with task that do not exceed the threshold for task success rate. In addition, even medical devices with sufficient safety and efficiency cannot guarantee absolute safety, so it is suggested to continuously evaluate user feedback even after introducing them to the actual site.

An Experimental Study on the Runout Characteristics of Spindle State Monitoring Using an Optical Fiber Displacement Sensor (광 파이버 변위 센서를 이용한 주축 모니터링 시 나타나는 런아웃 특성에 대한 실험적 고찰)

  • 신우철;박찬규;정택구;홍준희;이동주
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.472-477
    • /
    • 2003
  • Spindle state monitoring is getting more and more important according to the technology trend of spindle that is accurate and automated. Spindle state monitoring is to measure the state of rotation vibrations. The spindle rotation error motion detected by sensing device includes rotation object's unbalance, external forced vibrations, shape error of spindle, as well as measuring error of monitoring device. In this paper, we have inspected the runout characteristics. Also, we introduce the way to exclude the runout element that appear while you monitor a spindle state.

  • PDF

Multivariate Monitoring of the Metal Frame Process in Mobile Device Manufacturing (실시간 설비데이터를 활용한 휴대폰 메탈 프레임 공정의 다변량 모니터링)

  • Kang, Seong Hyeon;Kim, Seoung Bum
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.6
    • /
    • pp.395-403
    • /
    • 2016
  • In mobile industry, using a metal frame of devices is rapidly increased for thin and stylish designs. However, fabricating metal is one of the difficult processes because the sophisticated control of equipment is required during the whole machining time. In this study, we present an efficient multivariate monitoring procedure for the metal frame process in mobile device manufacturing. The effectiveness of the proposed procedure is demonstrated by real data from the mobile plant in one of the leading mobile companies in South Korea.

Adaptive Wireless Sensor Network Technology for Ubiquitous Container Logistics Development

  • Chai, Bee-Lie;Yeoh, Chee-Min;Kwon, Tae-Hong;Lee, Ki-Won;Lim, Hyotaek;Kwark, Gwang-Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.317-320
    • /
    • 2009
  • At the present day, the use of containers crisscrossing seven seas and intercontinental transport has significantly increased and bringing the change on the shape of the world economy which we cannot be neglected. Additionally, with the recent technological advances in wireless sensor network (WSN) technologies, has providing an economically feasible monitoring solution to diverse application that allow us to envision the intelligent containers represent the next evolutionary development step in order to increase the efficiency, productivity, utilities, security and safe of containerized cargo shipping. This paper we present a comprehensive containerized cargo monitoring system which has adaptively embedded WSN technology into cargo logistic technology. We share the basic requirement for an autonomous logistic network that could provide optimum performance and a suite of algorithms for self-organization and bi-directional communication of a scalable large number of sensor node apply on container regardless inland and maritime transportation.

  • PDF

Trace Monitoring System of Mobile Devices based on GML (GML 기반 모바일 디바이스 추적 모니터링 시스템)

  • Jeon, Chang-Young;Park, Jun;Lee, Jin-Seok;Song, Eun-Ha;Jeong, Young-Sik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.34 no.1
    • /
    • pp.19-27
    • /
    • 2007
  • Entering the 21st century, the demand on information service via mobile devices is skyrocketing along with the popularization of computers and mobile communication devices and the rapid development of wireless communication technology. In particular, as mobile device service such as LBS and Telematics becomes highlighted, the management of mobile devices is ever more drawing attention. However, since there is no fixed standard on geographical space data, many commercialized monitoring systems do not use common geographical space data but independent geographic information. Furthermore, as it is impossible to save location information of each mobile device by integrating such information after acquiring them, it is difficult to trace management. Therefore, in this paper, geographic data with DXF. DWG and SHP format, which are commonly used files, were created and visualized by GML format, OGC standard advice. And then, TMS(Trace Monitoring System of Mobile Device) that can trace and manage information after acquiring and saving space information that show the movement of users was implemented.

High-Speed Monitoring Device to Inspect Inkjet Droplets with a Rotating Mirror and Its Measuring Method for Display Applications (잉크젯을 이용한 디스플레이 생산을 위한 회전 미러 방식의 잉크젯 액적 모니터링 장비 및 측정법 연구)

  • Shin, Dong-Youn
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.6
    • /
    • pp.525-532
    • /
    • 2017
  • The development of an inkjet-based manufacturing machine for the production of next-generation displays using organic and quantum-dot light emitting diodes at a low cost has been conducted. To employ inkjet printing in production lines of displays, the development of a high-speed inkjet-monitoring device to verify the reliable droplet jetting status from multiple nozzles is required. In this study, an inkjet monitoring device using a rotatable mirror with rotary and linear ultrasonic motors is developed in place of a conventional, linear reciprocating, motion-based inkjet monitoring device. Its performance is also demonstrated. The measurements of circular patterns with diameters of $10{\mu}m$, $30{\mu}m$, and $50{\mu}m$ are performed with the accuracies of $0.5{\pm}1.0{\mu}m$, $-1.2{\pm}0.3{\mu}m$, and $0.2{\pm}0.5{\mu}m$, respectively, within 17 sec. By optimizing the control program, the takt time can be reduced to as short as 8.6 sec.

U-Healthcare Patch Type Wireless Body Temperature Monitoring System (유헬스케어 패치형 무선 체온 모니터링 시스템 구현)

  • Park, Young-Sang;Kwon, Oeon;Cho, Hyun-Sung;Son, Jaebum
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.1
    • /
    • pp.55-61
    • /
    • 2020
  • Recently, there have been many research on fever management using u-healthcare technology. Especially, fever of infants requires continuous monitoring of body temperature by parents. For infants between 4 weeks and under 5 years old, it is recommended to use an electronic thermometer or chemical thermometer in the axilla, or to use an infrared thermometer. However, in order to overcome the reality of not being able to waste significant time on continuous monitoring, there have been demands of patch type thermometers with the internet of things (IoT) and wireless communication technologies. Existing IoT thermometers are difficult to attach to infants' body because they do not take into account its size, and their interoperability is not guaranteed because they do not comply with standards in communication. Therefore, in this study, a patch-type thermometer with a diameter of 20 mm and a weight of 2.9 g was developed to manage the fever of infants, while it communicates wirelessly with Bluetooth Low Energy (BLE) communication protocol and complies with IEEE 11073 PHD(Personal Health Device) at the same time. We verified its performance under the requirements of thermometers regulated by the Korean Ministry of Food and Drug Safety.