• Title/Summary/Keyword: monitoring device

Search Result 1,398, Processing Time 0.031 seconds

The Development of Real-Time Free Length Monitoring Systems Interlocking with PLC Device (PLC 장비와 연동하는 실시간 자유장 모니터링 시스템 개발)

  • Jung, Jin-uk;Kim, Su-hong;Jin, Kyo-hong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.539-541
    • /
    • 2016
  • In this paper, we proposed real time free-length monitoring systems interlocking with the spring free-length sorter which shows the state of production connected to the spring production device. This systems enable the administrator to check the quality or quantity of product and the defect rate, etc., in the remote place. The proposed systems are comprised of the wireless device interlocking with PLC device, the server program, and user GUI program. The wireless device transmits the received data from PLC device to server program using Wi-Fi. Server program represents the data from the wireless device on the screen and insert those data into database. User GUI program shows data stored in database and supports the function which converts the stored data in DB to excel file.

  • PDF

Development of a Prototype System for Active Emergency Call Services (능동적 응급 호출 서비스 시스템 프로토타입 개발)

  • Han, Won-Hee;Song, Eun-Ha;Han, Sung-Kook;Jeong, Young-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.1016-1024
    • /
    • 2008
  • In this paper, we designed and implemented the ACE(ACtive Emergency call service system) system for emergency call service actively. ACE system has two physical components; E-Device(Emergency Mobile Device) and E-Server(Emergency Server). The role of E-Device is the mobile device in order to call emergency by using mild handi-capped, the elderly and children who are able to communicate theirs intention to another. E-Server is the server for management E-devices with realtime monitering. E-Device will be developed to the portable size for easily mild handi-capped, the elderly and children. When they need the service of emergency call, the button of E-device can be used and the call signal is transmitted to the emergency office and the guardian through Internet and CDMA. E-server should be developed the integrated control system for management of E-Devices basically. And it also supported to realtime monitoring of E-devices with respect to high quality of emergency call service for rise the efficiency.

  • PDF

Design and Implementation of Remote Device Management System based on LoRa Communication (LoRa 통신기반 원격 장비 관리 시스템 설계 및 구현)

  • Kim, Dong-Hyun;Lee, Chang-Hong;Kim, Jong-Deok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.12
    • /
    • pp.1654-1661
    • /
    • 2020
  • Internet of Things(IoT) technology can remotely collect and control a sensing information of device by attaching a small communication device to equipment that does not support communication. Low-Power Wide-Area Network (LPWAN), a low-power, long-distance communication technology, was proposed to support IoT technology, and Long Range(LoRa) is representative. Various systems, including network device, can collect and control the status information of device in real time through remote access. However, when a network failure occurs, remote access and status monitoring are impossible unless there is a separate additional network. To overcome this problem, in this paper, we propose an independent remote device management system that can be easily attached to device, which monitors and controls equipment remotely using an independent network. We will design and implement the proposed system, via which we will show its practicality and expandability.

The Design of Monitoring & Control(M&C) for KUS RFS in KASS (KASS 위성통신국 RF시스템 감시제어장치 설계)

  • Kim, Taehee;Sin, Cheonsig
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.50-55
    • /
    • 2017
  • In this paper, the design of the RF system monitoring and control system of KUS (KASS: KASS Uplink Station) which constitutes KASS (Korea Augmentation Satellite System) is described. The Korean satellite calibration system is named KASS and aims to develop the SBAS system of the APV-1 level SoL service level and the CAT-1 test operation technology. Software and hardware development environment, function and algorithm of supervisory control device, structure of supervisory control device, and user interface were designed to implement KUS / RFS monitoring control device. We have secured the stability and reliability of the system by using the monitoring and control system design of the COMS (Communication Ocean & Meteorological Satellite) and the Korea Satellite 5A / 7 control system, which has already been used for the design of the surveillance control system. In addition, we have made it possible to provide the user interface according to the actual operator's request more conveniently.

A Implementation of Acer Pictum Sap Integrated Management System based on Energy Harvesting and Monitoring System (에너지 하베스팅 및 모니터링 기반의 고로쇠 수액 통합 관리 시스템 구현)

  • Jung, SeHoon;Jo, KyeongHo;Kim, JunYeoung;Park, Jun;Kim, JongChan;Choi, SooIm;Sim, ChunBo
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.11
    • /
    • pp.1324-1337
    • /
    • 2019
  • This study set out to investigate an energy harvesting device to ensure stable energy supply to batteries and data collection devices and a monitoring system for acer pictum sap to check collected data. Acer pictum sap farmers have written down weather information and yield of acer pictum sap manually for data storage. Since the job is done manually, there are many missing values in their data. In addition, it is not easy to manage batteries due to the characteristics of the areas where acer pictum sap is collected. The present study thus decided to build an energy harvesting device based on new renewable energy to ensure stable energy supply by taking into consideration power load, daily power consumption, and number of days with no sunshine for various devices. For a monitoring system, the investigator proposed a JSP-based web page to monitor temperature, humidity, volume of collected water, and battery state in real time. The proposed energy harvesting device was applied to reduce missing values in data. It promoted stable energy supply to the batteries and data collection devices, reducing the percentage of missing values in data from 30.55% to 0%.

Monitoring Technique and Device of Surface Contamination for Line-Post Insulator (지지애자의 표면오염 모니터링 기술 및 장치)

  • Kil, Gyung-Suk;Park, Dae-Won;Jung, Kwang-Seok;Kim, Sun-Jae;Seo, Dong-Hoan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.5
    • /
    • pp.413-417
    • /
    • 2010
  • Line to ground faults by deterioration of insulators has frequently occurred in power system, and the main cause is surface contamination of the insulators. The contamination of insulator is analyzed by monitoring the surface leakage current flowing them. The suspension insulator is monitored by installation of a zero-phase current sensor(ZCT), but the line-post insulator is impossible to apply the same method because of its large diameter structure. This paper proposed a detection method of surface leakage current for a line-post insulator, and it can easily be applied to new and/or built insulators. The leakage current is indirectly calculated from the potential difference between the metal electrode attached on the surface of insulator and the ground connector. To evaluate the performance of the proposed method, the leakage current is compared as a function of contamination condition controlled by the density of NaCl solution. The leakage current is proportioned to the density of NaCl solution, and the voltage detected by the electrode showed the same trend. From the experimental results, we designed and fabricated a monitoring device which is composed of a detection electrode, signal converter, microprocessor, and ZigBee, and its measurement range is $10{\mu}A{\sim}5mA$.

Light Modulation based on PPG Signal Processing for Biomedical Signal Monitoring Device (생체 정보 감시 장치를 위한 광변조 기법의 PPG 신호처리)

  • Lee, Han-Wook;Lee, Ju-Won;Jeong, Won-Geun;Kim, Seong-Hoo;Lee, Gun-Ki
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.503-509
    • /
    • 2009
  • The development of technology has led to ubiquitous health care service, which enables many patients to receive medical services anytime and anywhere. For the ubiquitous health care environment, real-time measurement of biomedical signals is very important, and the medical instruments must be small and portable or wearable. So, such devices have been developed to measure biomedical signals. In this study, we develop the biomedical monitoring device which is sensing the PPG signal, one of the useful signal in the field of ubiquitous healthcare. We design a watch-like biomedical signal monitoring system without a finger probe to prevent the user's inconvenience. This system obtains the PPG from the radial artery using a sensor in the wrist band. But, new device developed in this paper is easy to get the motion artifacts. So, we proposed new algorithm removing the motion artifacts from the PPG signal. The method detects motion artifacts by changing the degree of brightness of the light source. If the brightness of the light source is reduced, the PPG pulses will disappear. When the PPG pulses have disappeared completely, the remaining signal is not the signal that results from the changing blood flow. We believe that this signal is the motion artifact and call it the noise reference signal. The motion artifacts are removed by subtracting the noise reference signal from the input signal. We apply this algorithm to the system, so we can stabilize the biomedical monitoring system we designed.

Development of a Real-time Monitoring Device for Measuring Particulate Matter

  • Kim, Dae Seong;Cho, Young Kuk;Yoon, Young Hun
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, we have developed a real-time monitoring device for measuring $PM_{10/2.5/1}$ of ambient aerosol particles. The real-time PM (Particulate Matter) monitor was based on the light scattering method and had 16 channels in particle size. The laboratory and field tests were carried out to evaluate the performance of the PM monitor developed. Arizona Road Dust particles ranging from diameter of 0.1 to $20{\mu}m$ were generated as test particles in the laboratory test. The field test was carried out at the Seoul Meteorological Observatory. We can obtain the particle size and number concentration (particle size distribution) only from the real-time PM monitor developed. Therefore, the average density of aerosol particles was used to obtain the PM data from the particle size distribution. The $PM_{10/2.5/1}$ results of the PM monitor were compared with the data of the Grimm Dust Monitor (Model 1.108) and a beta ray gauge (Thermo Fisher Scientific). As a result, it was shown that the $PM_{10/2.5/1}$ results obtained by the real-time PM monitor agreed well with the data of the reference devices, and overall, the real-time PM monitor could be used as a PM monitoring device for real-time monitoring of the ambient particles.

Mobile exercise monitoring for personalized exercise prescription (맞춤형 운동처방을 위한 모바일 운동 모니터링)

  • Kang, Sunyoung;Kang, Seungae
    • Convergence Security Journal
    • /
    • v.15 no.5
    • /
    • pp.23-28
    • /
    • 2015
  • This study was carried out the exercise monitoring utilizing mobile device which is easily accessible and personalized exercise prescription based on it. For this, a variety of exercise monitoring and status of those were investigated and suggested the potential of personalized exercise prescription. If individual users send their body and vital informations using a mobile device, all informations are collected in u-Fitness center. After then exercise expert provide a customized prescription based on the collected information and feed data into database of u-Fitness center. System of U-Fitness center will provide the best personalized exercise prescription by automatically connecting to the content providers. In the future, a variety of mobile devices and services will work together and it can be evolved as an open platform that can be used for multiple services according to the needs of individual users on a single platform.

Cow Residual Feed Intake(RFI) monitoring and metabolic abnormality prediction system using wearable device for Milk cow and Beef

  • Chang, Jin-Wook;Kwak, Ho-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.10
    • /
    • pp.139-145
    • /
    • 2021
  • In this paper, by using the cattle feed intake, rumination, and in heat monitoring technology, RFI (Residual Feed Intake) monitoring and wearable devices and PCs for predicting abnormalities in budding target web and smart A monitoring system using a phone application was designed and implemented. With the development of this system, the farmer is expected to increase economic efficiency. By analyzing the feed intake, it is possible to identify the difference between the recommended feed amount based on the cow's weight and the feed amount consumed by the cow, and it is expected that early detection of metabolic disorders (abnormality of metabolism) is possible. Farmers using the results of this thesis can distinguish the cows with the most efficient performance, and the 6-axis motion sensor signals input from the wearable device attached to the cow's skin (neck) and the microphone attached to the wearable device. It is possible to measure the cow's rumination and feed intake through the sound of the cow's throat. In the future, improvements will be made to measure additional vital signs such as heart rate and respiration.