• Title/Summary/Keyword: monitoring camera

Search Result 754, Processing Time 0.026 seconds

Post-outburst observation of HBC722 in Pelican nebula

  • Yang, Yun-A;Sung, Hyun-Il;Lee, Sang-Gak;Jeon, Young-Beom;Lee, Jung-Eun;Sung, Hwan-Kyung;Kang, Won-Seok;Park, Keun-Hong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.148.1-148.1
    • /
    • 2011
  • We report the result of post-outburst observation of HBC722, the new FU Orionis-like young stellar object (also known as LkHa 188-G4 and PTF 10qpf; A. Miller et al., 2011). We have been monitoring this object since Nov. 2010 with KASINICS (Korean Astronomy and Space Institute Near Infrared Camera System) at Bohyun Optical Astronomy Observatory (BOAO). The observations were performed two times; the first observation was conducted in Nov. 19, 24, and 25, 2010. And the second one was done in March 22 and 25, 2011. We used three filters: J, H, and Ks band. We did aperture photometry with IRAF packages and standardized the photometric result (instrumental magnitude) with 2MASS data that were used as standard stars. As a result, we have found that the brightness of the target decreased in all bands and its colors reddened: the magnitudes and colors of the target are J=10.37, H= 9.49, Ks=8.59, J-H=0.88, and J-Ks=1.36 on Nov. 19, 2010. And those are J=10.81, H=9.81, Ks=9.28, J-H=1.00, and J-Ks=1.53 on March 25, 2011. The previous study showed the similar decrease of brightness in J and H band except for Ks band., They were J= 10.03, H= 9.14, and Ks= 8.65 on Sept. 2010 and those were J= 10.02, H=9.24, and Ks= 8.59 on Nov. 2010. Consequently, we can conclude that HBC722 is fading out continuously from last November to this March.

  • PDF

Preliminary Result from Rapid Cadence Photometric Monitoring of HBC722

  • Baek, Gi-Seon;Green, Joel D.;Pak, Soo-Jong;Lee, Jeong-Eun;Eon, Yi-Seulj;Park, Won-Kee;Choi, Chang-Su;Kang, Won-Seok;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.113.2-113.2
    • /
    • 2011
  • We observed a low-mass pre-main sequence star, HBC722 (also known as $LkH{\alpha}$ 188 G4), with Camera for QUasars in EArly uNiverse (CQUEAN) attached to 2.1 Otto Struve telescope at McDonald Observatory, USA. HBC722 is a new FU orionis-type object in the direction of NGC7000/IC5070, which produced large amplitude optical outbursts (${\delta}V$=4.7 mag over one year) for a few months and reached the peak in 2010 September. We carried out the photometric observation in SDSS r,i, and z band in 2011 April, July and August to monitor the long term decrease of its brightness. We also made continuous observation in r-band for half night in July, and whole two nights in August to investigate short term variability which could be related to the rotation of the central star or the inner circumstellar disk. In this poster, we present a preliminary result of the photometric observation for HBC722.

  • PDF

Design of Smart Digital Door Lock System Using Heterogeneous Communication (이종 통신을 이용한 스마트 디지털 도어락 시스템 설계)

  • Han, Yong-Sik;Cho, Hyun-Chul;Park, Jin-Tae
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.45-52
    • /
    • 2018
  • In this paper, we propose smart digital door lock system using heterogeneous communication. This system has efficient function using RF communication and Internet communication, and realizes access and real image of the passengers by combining camera control technology to secure original competitiveness with existing products. It uses the Internet of things and receive images to and from your smart-phone. And senses human behavior. In the simulated results, the image transmission rate of 90 % or more and the time required to transmit 10,000 images have an average transmission speed of 3 seconds. It is expected to secure competitiveness to increase the security of door lock in the future by enabling minimum security and fire monitoring service in real time.

A Swine Management System for PLC baed on Integrated Image Processing Technique (통합 이미지 처리기법 기반의 PLF를 위한 Swine 관리 시스템)

  • Arellano, Guy;Cabacas, Regin;Balontong, Amem;Ra, In-Ho
    • Smart Media Journal
    • /
    • v.3 no.1
    • /
    • pp.16-21
    • /
    • 2014
  • The demand for food rises proportionally as population grows. To be able to achieve sustainable supply of livestock products, efficient farm management is a necessity. With the advancement in technology it also brought innovations that could be harness in order to achieve better productivity in animal production and agriculture. Precision Livestock Farming (PLF) is a budding concept of making use of smart sensors or available devices to automatically and continuously monitor and manage livestock production. With this concept, this paper introduces a swine management system that integrates image processing technique for weight monitoring. This system captures pig images using camera, evaluate and estimate the weight base on the captured image. It is comprised of Pig Module, Breeding Module, Health and Medication Module, Weighr Module, Data Analysis Module and Report Module to help swine farm administrators better understand the performance and situation of the swine farm. This paper aims to improve the management in both small and big livestock raisers.

Variability Analysis of HBC722 using Lomb-Scargle Periodogram

  • Baek, Giseon;Pak, Soojong;Green, Joel D.;Jeon, Yiseul;Choi, Changsu;Lee, Jeong-Eun;Im, Myungshin;Meschiari, Stefano
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.52.1-52.1
    • /
    • 2013
  • We present preliminary results of the photometric variability analysis in SDSS r, i and z bands for a newly confirmed FU Orionis-type object, HBC 722. We observed HBC 722 from 2011 April to 2012 November, with Camera for Quasars in Early uNiverse (CQUEAN) attached to the 2.1m Otto Struve telescope at McDonald Observatory, USA. The rapid cadence monitoring observations (minute timescale) were conducted in chosen photometric nights during observation campaigns to get adequate number of samples for short term period analysis. As this object is in active state, temperature at the inner disk/stellar surface can be characterized by the colors between r, i and z bands. Also, It is theorized that a sudden cataclysmic accretion associated with FU Orionis-type outburst can give rise to detectable "hot spots" on the central star and rotational asymmetries in the disk instability region. Thus the periodic variabilities of three bands would trace the stellar rotation or Keplerian rotation at the instability region of the inner accretion disk. Additionally, the range of instabilities could be estimated on the assumption of a temperature distribution for the HBC 722 disk. This analysis can provide a clue for understanding enhanced disk accretion of Class II young stellar object.

  • PDF

Treefrog lateral line as a mean of individual identification through visual and software assisted methodologies

  • Kim, Mi Yeon;Borzee, Amael;Kim, Jun Young;Jang, Yikweon
    • Journal of Ecology and Environment
    • /
    • v.41 no.12
    • /
    • pp.345-350
    • /
    • 2017
  • Background: Ecological research often requires monitoring of a specific individual over an extended period of time. To enable non-invasive re-identification, consistent external marking is required. Treefrogs possess lateral lines for crypticity. While these patterns decrease predator detection, they also are individual specific patterns. In this study, we tested the use of lateral lines in captive and wild populations of Dryophytes japonicus as natural markers for individual identification. For the purpose of the study, the results of visual and software assisted identifications were compared. Results: In normalized laboratory conditions, a visual individual identification method resulted in a 0.00 rate of false-negative identification (RFNI) and a 0.0068 rate of false-positive identification (RFPI), whereas Wild-ID resulted in RFNI = 0.25 and RFNI = 0.00. In the wild, female and male data sets were tested. For both data sets, visual identification resulted in RFNI and RFPI of 0.00, whereas the RFNI was 1.0 and RFPI was 0.00 with Wild-ID. Wild-ID did not perform as well as visual identification methods and had low scores for matching photographs. The matching scores were significantly correlated with the continuity of the type of camera used in the field. Conclusions: We provide clear methodological guidelines for photographic identification of D. japonicus using their lateral lines. We also recommend the use of Wild-ID as a supplemental tool rather the principal identification method when analyzing large datasets.

On Orbit Data Analysis About the Passive Cooling of MIRIS, a Compact Space Infrared Telescope

  • Lee, Duk-Hang;Moon, Bongkon;Jeong, Woong-Seob;Pyo, Jeonghyun;Lee, Chol;Kim, Son-Goo;Park, Youngsik;Lee, Dae-Hee;Park, Sung-Joon;Kim, Il-Joong;Park, Won-Kee;Seon, Kwang-Il;Nam, Uk-Won;Cha, Sang-Mok;Park, Kwijong;Park, Jang-Hyun;Yuk, In-Soo;Ree, Chang Hee;Jin, Ho;Yang, Sun Choel;Park, Hong-Young;Shin, Ku-Whan;Suh, Jeong-Ki;Rhee, Seung-Wu;Park, Jong-Oh;Lee, Hyung Mok;Matsumoto, Toshio;Han, Wonyong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.50.1-50.1
    • /
    • 2014
  • The Multi-purpose InfraRed Imaging System (MIRIS) is the main payload of Science and Technology Satellite 3 (STSAT-3), which was launched onboard Dnepr rocket from Russian Yasny Launch Base in November 2013. The MIRIS is an infrared (IR) camera, and the telescope has to be cooled down to below 200K in order to reduce thermal background noise. For the effective cooling and low-power consumption, we applied passive cooling method to the thermal design of the MIRIS. We also conducted thermal analysis and tested for the passive cooling before the launch of STSAT-3. After the launch, we have received State-of-Health (SOH) data from the satellite on orbit, including temperature monitoring results. It is important that the temperature of the telescope was shown to be cooled down to below 200K. In this paper, we present both the temperature data of the MIRIS on orbit and the thermal analysis results in the laboratory. We also compare these results and discuss the verification of the passive cooling.

  • PDF

Studies of vision monitoring system using a background separation algorithm during radiotherapy (방사선 치료시 배경분리알고리즘을 이용한 비젼모니터링 시스템에 대한 연구)

  • Park, Kiyong;Choi, Jaehyun;Park, Jeawon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.359-366
    • /
    • 2016
  • The normal tissue in radiation therapy, to minimize radiation, it is most important to maximize local tumor control rates in intensive research the exact dose to the tumor sites. Therefore, the initial, therapist accuracy of detecting movement of the patient fatigue therapist has been a problem that is weighted down directly. Also, by using a web camera, a difference value between the image to be updated to the reference image is calculated, if the result exceeds the reference value, using the system for determining the motion has occurred. However, this system, it is not possible to quantitatively analyze the movement of the patient, the background is changed when moving the treatment bed in the co-therapeutic device was not able to sift the patient. In this paper, using a alpah(${\alpha}$) filter index is an attempt to solve these limitations points, quantifies the movement of the patient, by separating a background image of the patient and treatment environment, and movement of the patient during treatment It senses only, it was possible to reduce the problems due to patient movement.

Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

Implementation of a Video Distribution Server to Enhance QoS of Network Cameras for the Video Surveillance System (영상 감시용 네트워크카메라의 서비스 품질 향상을 위한 영상분배서버 구현)

  • Jeong, Tae-Young;Yim, Kang-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.9
    • /
    • pp.67-74
    • /
    • 2008
  • This paper proposes, designs and implements an architecture of a server involved with the network camera based video surveillance systems to solve common problems including lack of inter-network operability at the video information sharing, drawback of bandwidth and processing-overhead caused by increase of the number of users, and difficulty of continuous monitoring over changes of network configurations. The proposed saver was designed to manage and service numerous network cameras and users as well as solving the existing problems by providing video distribution facility. Through the empirical study after applying the implemented server to a real video surveillance system we proved that the server can provide reasonable service quality while it processes several hundreds of simultaneous user connections under persisting more than one hundred connections to network cameras. We expect the developed video distribution server to enhance service quality of the large scale video surveillance systems for citizen-wide services such as traffic reporting informatics or natural calamities supporting.