• Title/Summary/Keyword: molten salt corrosion

Search Result 65, Processing Time 0.024 seconds

Review, Assessment, and Learning Lesson on How to Design a Spectroelectrochemical Experiment for the Molten Salt System

  • Killinger, Dimitris;Phongikaroon, Supathorn
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.209-229
    • /
    • 2022
  • This work provided a review of three techniques-(1) spectrochemical, (2) electrochemical, and (3) spectroelectrochemical-for molten salt medias. A spectroelectrochemical system was designed by utilizing this information. Here, we designed a spectroelectrochemical cell (SEC) and calibrated temperature controllers, and performed initial tests to explore the system's capability limit. There were several issues and a redesign of the cell was accomplished. The modification of the design allowed us to assemble, align the system with the light sources, and successfully transferred the setup inside a controlled environment. A preliminary run was executed to obtain transmission and absorption background of NaCl-CaCl2 salt at 600℃. It shows that the quartz cuvette has high transmittance effects across all wavelengths and there were lower transmittance effects at the lower wavelength in the molten salt media. Despite a successful initial run, the quartz vessel was mated to the inner cavity of the SEC body. Moreover, there was shearing in the patch cord which resulted in damage to the fiber optic cable, deterioration of the SEC, corrosion in the connection of the cell body, and fiber optic damage. The next generation of the SEC should attach a high temperature fiber optic patch cords without introducing internal mechanical stress to the patch cord body. In addition, MACOR should be used as the cell body materials to prevent corrosion of the surface and avoid the mating issue and a use of an adapter from a manufacturer that combines the free beam to a fiber optic cable should be incorporated in the future design.

The Effect of Yttrium on Corrosion Behavior of NiAl Intermetallic Compound in the Molten Carbonate Salt (용융탄산염내에서의 NiAl합금의 내식성에 미치는 Yttrium의 첨가 영향)

  • Hwang, Eung-Rim;Lee, Dae-Hui;Kim, Seon-Jin;Kang, Seong-Gun
    • Korean Journal of Materials Research
    • /
    • v.8 no.8
    • /
    • pp.685-692
    • /
    • 1998
  • Since a wet-seal area of Molten Carbonate Fuel Cell (MCFC) operated at $650^{\circ}C$ is exposed to severe environment, a life-time of MCFC is influenced by the corrosion resistance of separator. In order to improve corrosion resistance of 316L stainless steel used as separator material, AI- base alloy such as NiAI has been widely used as coat¬ing material on the wet-seal area. The purpose of this work is to develope a more protective coating material by adding yttrium on NiAI alloy. An immersion test and a polarization test were performed in molten carbonate salt at $650^{\circ}C$ to estimate corrosion resistance of the NiAI alloy and the NiAl/Y alloys with up to L5at% yttrium. NiAl/Y alloys showed better corrosion resistance than NiAI alloy. We found that more than 0.7 at% yttrium was required to improve the corrosion resistance of NiAI alloy in molten carbonate salt at $650^{\circ}C$.

  • PDF

Study on the NiAl Coating for Corrosion Resistance of Stainless Steel in Molten Carbonate Salt (용융탄산염에 대한 스테인레스강의 내식성 향상을 위한 NiAl 피복에 관한 연구)

  • Hwang, Eung-Rim;Gang, Seong-Gun
    • Korean Journal of Materials Research
    • /
    • v.7 no.1
    • /
    • pp.76-80
    • /
    • 1997
  • '4 NiAl coating process was applied on 316 stainless steel to retard the corrosion of the wet- seal area of separator for the molten carbonate fuel cell. The Nit11 phasc on the stainless steel substrate could be formed by pre-coating with Ni, plated with A1 and ther, heat treated at $800^{\circ}C$ for 3 hr in $H_2/N_2$ gas atmosphere. The corrosion protection behavior of YiAl coating layer was stuilied under immersion condition in molten cxhonate salt($62^{m}/_{o}Li_2CO_3-38^{m}/_{o}/K_{2}CO_{3}$) at $650^{\circ}C$. The NiAl coating layer ticposited on the AiSi 316 stainless steel had high corrosion resistance in molten carbor. dte salt. The corrosion resistance of XiAl (~~jpoared to be associated with the .A1 oxide formed on the surface of coating layer.

  • PDF

Enhanced salt coating on FeS2 surface with the addition of Li2O

  • Cheong, Hae-Won;Kang, Seung-Ho;Kim, Jong-Myong;Cho, Sung-Baek
    • Journal of Ceramic Processing Research
    • /
    • v.13 no.spc2
    • /
    • pp.198-201
    • /
    • 2012
  • The electrolytes in thermal batteries are nonconductive solids at ambient temperature, which prevent the self-discharge and corrosion. To meet severe environmental requirements and guarantee acceptable handling yields, all the pellets in cells should have adequate strength, especially for the cathodes due to their poor binding properties among FeS2 particles. By modifying the surface microstructure of FeS2 through molten-salt heat treatment, the inter-particle binding strength is greatly increased, resulting in the enhanced pellet strength and yield. The addition of Li2O also promoted the soft salt coating coverage of hard FeS2 particles, which can be explained by the enhanced wettability of the molten salt.

Corrosion Behavior of Austenitic Alloys in the Molten Salts of $LiCl-Li_2O_2$ ($LiCl-Li_2O_2$ 용융염계에서 오스테나이트계 합금의 부식거동)

  • 오승철;윤기석;임종호;조수행;박성원
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2003.11a
    • /
    • pp.373-378
    • /
    • 2003
  • As a part of assessment of the structural material for the molten salt handling system, corrosion behavior of austenitic alloys, Fe-base and Ni-base in the molten salt of $LiCl-Li_2O_2$ was investigated in the range of temperature; 650~$725^{\circ}C$, time; 24- 168h, $Li_2O$; 3wt%, mixed gas; Ar-10%$O_2$. In the molten salt of $LiCl-Li_2O_2$, Ni-base alloys showed higher corrosion resistance than Fe-base alloys. Fe-base alloy with low Fe and high Ni contents exhibited better corrosion resistance. The scales of $Cr_2O_3$, $FeCr_2O_4$ on Fe-base alloys were showed, and $Cr_2O_3$, $NiFe_2O_4$ on Ni-base alloys were also showed.

  • PDF

A Study on the Corrosion Behavior of Fe-Ni-Cr Alloys in Molten Salts of LiCl and LiCl-${Li_2}O$ (LiCl 및 LiCl-${Li_2}O$ 용융염에서 Fe-Ni-Cr 합금의 부식거동 연구)

  • Jo, Su-Haeng;Jang, Jun-Seon;Hong, Sun-Seon;Sin, Yeong-Jun;Park, Hyeon-Su
    • Korean Journal of Materials Research
    • /
    • v.10 no.7
    • /
    • pp.471-477
    • /
    • 2000
  • Corrosion behavior of Fe-Ni-Cr alloy in molten salts of LiCl and LiCl-$Li_2O was investigated in the tempera-ture range of $650~850^{\circ}C$. In the molten salt of LiCl, and internal oxidation of Fe occurred in the KSA(Kaeri Superalloy)-1 alloy without containing Cr, while a dense protective oxide scale of $LiCrO_2$ was formed in the KSA-4, Incoloy 800H and KSA-5 alloys. In the mixed molten salt of LiCl-$Li_2O$, internal oxidation of Fe and Cr took place in the KSA-1 and KSA-4 alloys, respectively. Non-protective porous oxide scales consisting of $LiCrO_2$ and Ni were formed in the Incoloy 800H and KSA-5. The corrosion rate of the alloys increased with the increase in Cr content and the corrosion rate followed the parabolic law for the alloy containing Cr content less than 8%, and the linear law for the alloy containing Cr content more than 8%. Such a corrosion behavior of the alloy in the mixed molten salt of LiCl-$Li_2O$ was interpreted in terms of the basic fluxing mechanism of protective oxide scale of $Cr_2O_3$.

  • PDF

Electrodeposition Characteristics of Corrosion Resistant Tantalum Coating Layer for Hydrogen Production Sulfide-Iodine Process (수소생산을 위한 Sulfide-Iodine 공정장치용 초내식 탄탈코팅층 전착특성)

  • Lee, Youngjun;Kim, Daeyoung;Han, Moonhee;Kang, Keangsoo;Bae, Gigwang;Lee, Jonghyeon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.6
    • /
    • pp.573-580
    • /
    • 2012
  • Corrosion resistance and basic physical properties of solid tantalum are not comparable to most of the structural metallic materials. The relative high cost and melting temperature of tantalum are obstacles to be widely applied to general engineering processes. Electrodeposition in molten salt enables compact and uniform tantalum coating. In this study, Ta was coated onto base metal (SUS316L) with different current densities (0.5, 5, $20mA/cm^2$) by using MSE (Molten Salt Electrodeposition). In this study, it showed that deposition efficiency and microstructure of Ta coating layer were strongly depended on current density. In the case of the current density of $5mA/cm^2$, densest microstructure was obtained. The current density above $5mA/cm^2$ caused non-uniform microstructure due to rapid deposition rate. Dense microstructure and intact coating layer contributed to significant corrosion resistance enhancement.