• 제목/요약/키워드: module sharing

검색결과 176건 처리시간 0.02초

Function-level module sharing techniques in high-level synthesis

  • Nishikawa, Hiroki;Shirane, Kenta;Nozaki, Ryohei;Taniguchi, Ittetsu;Tomiyama, Hiroyuki
    • ETRI Journal
    • /
    • 제42권4호
    • /
    • pp.527-533
    • /
    • 2020
  • High-level synthesis (HLS), which automatically synthesizes a register-transfer level (RTL) circuit from a behavioral description written in a high-level programming language such as C/C++, is becoming a more popular technique for improving design productivity. In general, HLS tools often generate a circuit with a larger area than those of hand-designed ones. One reason for this issue is that HLS tools often generate multiple instances of the same module from a function. To eliminate such a redundancy in circuit area in HLS, HLS tools are capable of sharing modules. Function-level module sharing at a behavioral description written in a high-level programming language may promote function reuse to increase effectiveness and reduce circuit area. In this paper, we present two HLS techniques for module sharing at the function level.

정보통신용 다병렬 운전의 모듈식 무정전전원장치 (Module UPS of multi-parallel operation for use in information & telecommunication systems)

  • 구태근;류지수;배상규;박근갑
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2007년도 학술대회
    • /
    • pp.390-393
    • /
    • 2007
  • The reliability as well as the power capability of the UPS system can be increased by replacing a single UPS unit with multiple small UPS units in parallel, resulting in a so-called module UPS. This module UPS system allows that a new module can be added or replaced while maintaining power to loads, which is a hot-swappable operation. In addition, it has desirable features such as ease of output power expandability, convenience of maintenance and repair, and high reliability. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. 5kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the module UPS system has a high power factor, a low distortion of output voltage and input current, hot-swappable operations and good load sharing characteristics.

  • PDF

CAN통신을 이용한 모듈전원의 병렬운전에 관한 연구 (A Study of Parallel Operation of Module Power using CAN Communication)

  • 박성미;이상혁;박성준;이배호
    • 한국산학기술학회논문지
    • /
    • 제12권8호
    • /
    • pp.3603-3609
    • /
    • 2011
  • 본 논문에서는 CAN(Controller Area Network) 통신을 이용한 균등한 전류 분배를 위한 새로운 부하분담(Load-sharing) 알고리즘(Algorithm)을 제안한다. 기존 아날로그 방식과는 달리 디지털 통신을 이용한 강인한 부하분담특성을 가지며, 모듈마다 독립된 제어기(전압제어기, 전류제어기)가 구성되어 있으며, 마스터(Master)의 지령치 모듈의 지령치에 따라 슬레이브(slave)모듈이 부하분담을 수행한다. 또한 각 모듈 상태를 파악하기 위해 별도의 제어선을 사용하여 모듈의 고장 상태 및 고장난 모듈의 위치를 정확히 파악함으로써, 효율적이고 고속의 부하분담을 구현하였다. 제작된 병렬 시스템은 각 모듈마다 독립된 제어기가 구성되어 있으며, 본 논문에서는 PSIM을 통한 시뮬레이션과 시작품 제작을 통해 제안된 알고리즘의 타당성을 검증하였다.

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Choi Y.K.;Ko T.G.
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.987-993
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Furthermore, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3kVA modules are designed and implemented to confirm the effectiveness of the proposed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristic.

  • PDF

A Study on a Single-Phase Module UPS using a Three-Arm Converter/Inverter

  • Koo, Tae-Geun;Byun, Young-Bok;Joe, Ki-Yeon;Kim, Dong-Hee;Kim, Chul-U
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제3B권1호
    • /
    • pp.44-51
    • /
    • 2003
  • The module UPS can flexibly implement expansion of power system capacities. Further-more, it can be used to build up the parallel redundant system to improve the reliability of power system operation. To realize the module UPS, load sharing without interconnection among parallel connecting modules as well as a small scale and lightweight topology is necessary. In this paper, the three-arm converter/inverter is compared with the general full-bridge and half-bridge topology from a practical point of view and chosen as the module UPS topology. The switching control approaches based on a pulse width modulation of the converter and inverter of the system are presented independently. The frequency and voltage droop method is applied to parallel operation control to achieve load sharing. Two prototype 3㎸A modules are designed and implemented to confirm the effectiveness of the pro-posed approaches. Experimental results show that the three-arm UPS system has a high power factor, a low distortion of output voltage and input current, and good load sharing characteristics.

효과적인 수중로봇 S/W 프레임웍 구현을 위한 데이터 공유구조 (Data Sharing Architecture for an Effective Implementation of Underwater Robot S/W Framework)

  • 정순용;최현택
    • 전자공학회논문지SC
    • /
    • 제48권2호
    • /
    • pp.1-8
    • /
    • 2011
  • 수중로봇 S/W 프레임웍은 센서 데이터 처리, 추진기 제어, 인지 및 행위 제어 등의 다양한 하위모듈로 구성된다. 로봇의 성능은 알고리즘 자체의 우수성 뿐 아니라 그 구현에도 큰 영향을 받는데, 효과적인 구현에 가장 큰 영향을 미치는 부분 중의 하나는 모듈간의 신호 및 데이터 전달을 담당하여 센싱 및 제어 주기에 영향을 주는 데이터 공유 모듈의 효율성이다. 이상적인 데이터 공유 모듈은 시스템의 H/W 및 S/W 구성에 상관없이 데이터 싱크로부터 데이터 소스에 지연 없이 접근할 수 있게 해야 한다. 그러나 실제에 있어서는 시스템 구성 특성에 의한 데이터 소스 모듈의 접근 처리 용량 한계, 네트워크 지연 및 운영체제의 스케쥴링 등으로 인하여 다양한 접근 지연이 요인이 존재한다. 본 논문은 수중로봇과 같이 소수의 컴퓨터로 이뤄진 소규모 분산시스템에서 이러한 접근 지연을 효과적으로 처리하기 위한 데이터 공유 모듈 구조 및 프로그래밍 모델을 제안하고 있다.

디지털 병렬 통신을 이용한 부하분담 알고리즘 (Load-Sharing Algorithm using Digital Parallel Communication)

  • 박성미;김춘성;이상혁;이상훈;박성준;이배호
    • 전력전자학회논문지
    • /
    • 제16권1호
    • /
    • pp.50-57
    • /
    • 2011
  • 본 논문에서는 마이컴(ATmega-2560) 기반의 디지털 통신 방식을 이용한 새로운 부하분담(Load-sharing) 알고리즘(Algorithm)을 제안한다. 기존의 아날로그 방식과 달리 고속 통신과 디지털 제어를 수행하고 실시간 제어를 위한 시분할 토큰버스 방식을 적용함으로서 효율적인 부하분담 및 리던던시(Redundancy)를 구현하였다. 또한 자동 ID 설정 알고리즘을 적용함으로서 시스템 비용을 낮추었으며, 제어기의 전압 및 전류 적분값을 공유하는 새로운 알고리즘으로 시스템의 속응성을 향상시켰다. 제작된 병렬 시스템은 각 모듈마다 독립된 제어기가 구성되어 있으며, 마스터(Master) 모듈의 지령치에 따라 슬레이브(Slave) 모듈이 부하분담을 수행한다. 본 논문에서는 PSIM을 통한 시뮬레이션과 시작품 제작을 통해 제안된 알고리즘의 타당성을 검증하였다.

서로 다른 PDM 시스템 간에 OpenPDM을 이용한 제품데이터의 교환 (Sharing Product Data among Heterogeneous PDM Systems Using OpenPDM)

  • 양정삼;한순흥;문두환
    • 한국CDE학회논문집
    • /
    • 제13권2호
    • /
    • pp.89-97
    • /
    • 2008
  • Today's manufacturing environment is becoming a distributed manufacturing process in which a unique and specialized technological background is required in specific domains rather than having a single company execute all the manufacturing processes. This phenomenon is especially true in the automotive industry, where the sharing of product data between companies is rampant; however, this kind of interoperability causes many problems. When each company has its own method of managing product data, the sharing of product data in a distributed environment is a major problem. A data translator module or a data mapping module had to be developed for the exchange of data in heterogeneous systems of product data management (PDM); moreover, this type of module must be continually changed and improved due to the fact that PDM systems change for many reasons. In addition, the growth in corporate partnerships deepens the burden of developing and maintaining this module and creates further data exchange problems due to the increasing complexity of the system. This paper introduces a way of exchanging product data among heterogeneous PDM systems through the use of OpenPDM, which is a kind of virtual data warehouse. The implementation of a PDM integrating system is also discussed with respect to the requirement for a logical integration of product data which are physically distributed.

A Study on the IPv6 Multihoming Mechanism using Loadsharing Broker.

  • Kim, Dong-Kyun;Park, Hak-Soo;Kim, Seong-Hae;Whang, Il-Sun
    • 지식정보인프라
    • /
    • 통권7호
    • /
    • pp.141-148
    • /
    • 2001
  • This paper describes a mechanisms for IPv6 multihomming with loadsharing broker, focusing on the interdomain scalability and load sharing with redundancy on IPv6 networks. Unlike currently-practiced IPv4 multihoming, this model does not impact the worldwide routing table size, also it provides inbound load sharing at site level based on router renumbering, and multiple-prefix assigning techniques of IPv6. The proposed model has four modules such as building interfaces MIB module, priority list maintaining module, load detection module, and RRP configuration module.

  • PDF

Interleaved 부스트 컨버터의 새로운 전류 분배 기법 (A Novel Current Sharing Technique for Interleaved Boost Converter)

  • 민병선;박남주;현동석
    • 전력전자학회논문지
    • /
    • 제12권2호
    • /
    • pp.165-173
    • /
    • 2007
  • 본 논문에서는 캐리어 상승 기울기 보상을 통한 교호 승압 컨버터(Interleaved Boost Converter: IBC)의 새로운 전류 분배 기법을 제안한다. 교호 승압 컨버터는 저 전압 입력을 상승시키면서 대전류 출력 운용이 가능한 DC/DC 컨버터로서 단일 컨버터에 비해 다양한 장점을 갖고 있으나, 병렬로 연결된 모듈 간 전류의 분배가 여전히 주요한 문제로 남아있다. 제안한 기법은 이러한 문제를 해결하기 위해 마스터-슬레이브 전류 분배 기법에 근거하여 병렬로 연결된 모듈 간 전력과 상전류를 균등하게 제어할 수 있다. 기존의 균등 전류 분배 기법과 달리 슬레이브 모듈에 사용된 스위칭 소자의 전류 정격이 마스터 모듈 대비 상대적으로 낮은 스위칭 소자가 사용되었다 하더라도 제안한 기법을 통해 최적의 전류 분배를 이룰 수 있다. 제안한 기법의 유효성을 보이기 위해 시뮬레이션과 실험을 통해 이를 검증하였다.