• 제목/요약/키워드: module efficiency

Search Result 1,294, Processing Time 0.033 seconds

The Development of Level Net Information System (수준망(水準網) 정보(情報)시스템의 개발(開發))

  • Lee, Suck Chan;Cho, Kyu Jon;Lee, Chang Kyung;Choi, Byoung Gil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.39-49
    • /
    • 1991
  • An information system to manage leveling data efficiently is presented. The system is consisted of input, adjustment, and query/answer module. The input module manipulating leveling data is based on the chain structure. The adjustment module adjusts the abservations by least squares method, and tests outlier by Baarda's data snooping method. The query/answer module serves user with the height and location of bench marks. In this system, the efficiency of works was increased as a result of removing the boring routine by applying the characteristics of leveling data. If necessary, for the special purpose, the system is expanded easily by appending some pertinent unit modules.

  • PDF

Experimental Study of a Power-Over-Fiber Module and Multimode Optical Fiber for a Fishing Camera System

  • Lee, Hyuek Jae;Jung, Gwang S.
    • Current Optics and Photonics
    • /
    • v.1 no.5
    • /
    • pp.468-473
    • /
    • 2017
  • We determined the feasibility of a fishing camera system using an optical fiber as the fishing line by testing a power-over-fiber (POF) module and multimode optical fiber. Operation of the remote camera module (RCM) without the battery was preferred because the removal of the charging or battery replacement section enabled a waterproof single-body type design. The average efficiency of the photovoltaic power converter (PPC) in the tested POF module was 32.6% at 820 nm, and thus, a high-power laser of at least 1.27 W was required for operating the developed RCM with an electrical dissipation of 413 mW. Because the optical fiber was wound on a fishing reel, composite loss composed of bending and tensile loss occurred. To mitigate the composite loss, we employed a simple holder that showed an improvement in the composite loss of 0.38 dB to 0.8 dB, which was considerably better than the losses without the holder.

A Computational Study on the Cooling Performance of a Near Infrared Radiative Heating System (근적외선 가열 시스템의 냉각 성능에 대한 수치적인 연구)

  • Yoo, Keun-Pyo;Han, Minsub;Kim, Jae-Duck;Choi, Won-Taek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.5
    • /
    • pp.289-296
    • /
    • 2013
  • A near infrared (NIR) heating system has advantages over the conventional convection-based systems, in terms of heating uniformity and energy efficiency. When it is over-heated during its operation, the radiation lamp gets blackened, and the life of the radiation module becomes severely limited. The heat transfer system in the module is based on a high operating-temperature, and the radiation makes it difficult to analyze in detail the reliability issue, with an experimental approach alone. We developed a numerical heat-transfer model of the NIR heating system. We applied a ray-tracing method on the radiative heat transport, and a finite volume method on the conductive and convective systems, respectively. The cooling performance of the system is presented, based on the energy and flow distributions in the module. The factors that directly affect the module life are analyzed, such as the surface temperatures of the lamp glass and the reflector, and design improvements are discussed.

A study of high-efficiency rotating condensing hybrid solar LED street light module system (고효율 회전 집광형 하이브리드 태양광 LED 가로등 모듈 시스템 연구)

  • Min, Kyung-Ho;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.50-55
    • /
    • 2021
  • Solar power generation, which is one of the methods of using solar energy, has a high possibility of practical implementation compared to other renewable energy power generation, and it has the characteristic that it can generate as much power as needed in necessary places. In addition, maintenance is easy, unmanned operation is possible, and power management can be performed more efficiently if operated in a hybrid method with existing electric energy. Therefore, in this study, numerical analysis using a computer program was performed to analyze the efficient operation and performance improvement of solar energy of the rotating condensing type solar LED street lamp. As a result, the two-axis tracking type could obtain 15.23 % more electricity per year than the fixed type, and additional auxiliary power generation was required for the fixed type by 19 % per year than the tracking type. As a result of computational fluid dynamics(CFD) simulation for PV module surface temperature prediction, the The surface temperature of the Photovoltaics(PV) module incident surface was predicted to be about 10℃ higher than that of the fixed type.

A New pattern Diffuser for LCD Backlight Application

  • Tai, Tsai-Lin;Li, Yu-Tang;Chu, Chang-Sheng;Tien, Wan-Ting;Fan, Chih-Hsun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1450-1452
    • /
    • 2009
  • In this work, a plastic diffuser which has a surface similar to Sinusoidal wave profile for application of LC D backlighting is proposed. This new pattern diffuser is achieved the values of the transmission efficiency an d diffusion efficiency all over 70%, and it also has the value about gain over 1.1. Additionally, this new patter n diffuser has high uniformity when we put it in the LCD backlight module and its thickness is only 2mm. With these foregoing properties, this diffuser film can widely applied to LCD displays systems etc.

  • PDF

Thermal Characteristics Evaluation of Concentrated Hybrid Panel with cooling system on PV module (PV모듈의 냉각장치를 적용한 집속형 복합패널의 집열 특성 평가)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.3
    • /
    • pp.47-52
    • /
    • 2005
  • Normally if sunlight is directed on a solar cell without any increasing in temperature, the amount of absorption energy per unit area of each cell is increasing. In a silicon solar cell. however, cell conversion efficiency decreases with the increase of temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. We tried to design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect and use thermal energy more effectively. We compared performance of this new hybrid panel with current thermal panel. We also evaluated conversion efficiency, thermal capacity and confirmed cooling effects from thermal absorption efficiency.

An Efficiency Improvement of the Photovoltaic Generation System by Using the PPT based MPPT Converter (PPT 기반 MPPT 컨버터에 의한 태양광 발전시스템의 효율 개선)

  • Lee, Eun-Chul;Lee, Seong-Ryong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.4
    • /
    • pp.216-223
    • /
    • 2006
  • In this paper, a methodology for the efficiency improvement of the photovoltaic system without adding some elements or increasing the cost comparing with the conventional system is discussed. It is suggested the optimal photovoltaic module configuration through its performance analysis, and also the suitable maximum power point tracking (MPPT) voltage considered the system cost and the efficiency of the converter. The high efficiency photovoltaic system by using the parallel power transfer (PPT) based MPPT converter is proposed and analyzed theoretically comparing with the conventional Buck type MPPT converter. Finally, it is designed and implemented the proposed photovoltaic system for supplying DC 48V by using the PPT based MPPT converter. And the effect of the efficiency improvement and the usefulness of the proposed system is proved through some preliminary simulation and experiment results.

Comparative Analysis of Efficiency and Power Density of Single-Phase and 3-Level Boost Converters for PV System (태양광 시스템용 단상 및 3-레벨 부스트 컨버터의 효율 및 전력밀도 비교 분석)

  • Kim, Chul-Min;Kim, Jong-Soo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.2
    • /
    • pp.127-132
    • /
    • 2020
  • In this study, single-phase and three-level boost converters applied to the photovoltaic system were compared and analyzed in terms of efficiency and power density according to the input voltage and load conditions. For accurate analysis of efficiency, the losses in each device of the single-phase and three-level boost converters were derived using mathematical equations and simulations by using the PSIM thermal module. Then, the losses were compared with the efficiency confirmed through the actual experiments. Results confirmed that the efficiency and power density can be improved by applying the three-level boost converter to the system according to the selection of the switching frequency.

Electric Vehicle Wireless Charging Control Module EMI Radiated Noise Reduction Design Study (전기차 무선충전컨트롤 모듈 EMI 방사성 잡음 저감에 관한 설계 연구)

  • Seungmo Hong
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.16 no.2
    • /
    • pp.104-108
    • /
    • 2023
  • Because of recent expansion of the electric car market. it is highly growing that should be supplemented its performance and safely issue. The EMI problem due to the interlocking of electrical components that causes various safety problems such as fire in electric vehicles is emerging every time. We strive to achieve optimal charging efficiency by combining various technologies and reduce radioactive noise among the EMI noise of a weirless charging control module, one of the important parts of an electric vehicle was designed and tested. In order to analyze the EMI problems occurring in the wireless charging control module, the optimized wireless charging control module by applying the optimization design technology by learning the accumulated test data for critical factors by utilizing the Python-based script function in the Ansys simulation tool. It showed an EMI noise improvement effect of 25 dBu V/m compared to the charge control module. These results not only contribute to the development of a more stable and reliable weirless charging function in electric vehicles, but also increase the usability and efficiency of electric vehicles. This allows electric vehicles to be more usable and efficient, making them an environmentally friendly alternative.

Design of DC OPTIMIZER for Maximum Power Generation System of Solar Panel (태양광 패널의 최대 전력 발생 시스템을 위한 DC OPTIMIZER 설계)

  • Kim, Jeong Gyu;Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.1
    • /
    • pp.40-44
    • /
    • 2018
  • In this paper, the efficiency of the solar system is lowered due to the partial shading such as the environmental factors of the solar panel. In order to solve this problem, a DC OPTIMIZER is proposed for a maximum power generation system of a photovoltaic panel. The proposed DC OPTIMIZER is composed of a buck structure that performs the maximum power point tracking (MPPT) control of each module of the solar panel, thus maximizing the efficiency. In order to verify the proposed DC Optimizer, the efficiency was measured by varying the irradiance using a solar simulator instead of the solar panel. As a result, it showed high efficiency characteristics as the maximum energy conversion efficiency was 99.3% at $800w/m^2$, $900w/m^2$, and the average efficiency was 99.06% excluding $100w/m^2$. The maximum efficiency of MPPT was 99.97% at $200w/m^2$, efficiency showed excellent performance.