• 제목/요약/키워드: module efficiency

검색결과 1,279건 처리시간 0.027초

방열특성 제어를 위한 PWM 전류제어 기반 LED 모듈 개발 (Development of LED Module Control-based PWM Current for Control of Heat-dissipation)

  • 이승현;문한주;허성범;최성대
    • 한국기계가공학회지
    • /
    • 제14권6호
    • /
    • pp.129-135
    • /
    • 2015
  • This paper shows significant methods that improve the lifespan of LED modules as well as efficiently using an aluminum heat-sink for LED module in high power. It proposes a method that raises stability and lifespan to protect LED modules and the power unit when the LED module has been used for a long hours at high temperatures. During the research, we applied a method of pulse-width modulation (PWM) in order to prevent the phenomenon that the entire power of a system is turned off and the lifespan is reduced when the LED nodule reacts to the high temperatures. To protect the LED module and SMPS based on high efficiency, a temperature sensor is attached underneath the circuit board and the sensor measures the temperature of circuit board when the LED module is powered on. The electrical power connected to SMPS is controlled by PWM when the temperature of the LED module reaches a particular temperature.

자동차용 모듈화 도어의 동특성 평가 시험법 개발 (The Development of Evaluation Process for Dynamic Characteristics of Door Module)

  • 배철용;김찬중;권성진;이봉현;장운성;이준우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.291-296
    • /
    • 2007
  • This study presents the evaluation process for door module. Its objective evades the resonance generated at module plate due to the operation of window regulator motor. For this study, the design improvement process is composed of experimental methods having three steps. First step is modal analysis at door assembly status for acquisition of dynamic characteristics which are modal frequency and damping. Second step is a vibration experiment to get the test mode considered an efficiency of window regulator motor. Last step is a vibration measurement by the form of $6{\times}6$ array on module plate. A vibration measurement of 6x6 array form can be got to three analysis results which are a transfer path of vibration using cross correlation function, a vibration map using OA level and a contribution by frequency band using coherent output power spectrum on module plate. These results are applied to SDM(structural dynamic modification) for design improvement to get around the resonance on module plate by the excitation of window regulator motor.

  • PDF

후면 유리 종류에 따른 투과형 태양광발전모듈의 열 및 광 특성 분석 (Analysis of Thermal and Optical Characteristic of Semi-transparent Module according to Various Types of the Backside Glass)

  • 박경은;강기환;김현일;김경수;유권종;김준태
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • Building Integrated PV(BIPV) is one of the best fascinating PV application technologies. To apply PV module in building, various factors should be reflected such as installation position, shading, temperature, and so on. Especially a temperature should be considered, for it affects both electrical efficiency of a PV module and heating/cooling load in a building. This study investigates a semitransparent PV module that is designed as finished material for windows. Therefore it needs to considerate about the optical characteristics of the transparent module. It reports the effect of thermal and optical characteristics of the PV module on generation performance. The study was performed by measuring sun spectrum and luminance through the PV modules and by monitoring the temperature and experiment. The results showed that 1 degree temperature rise reduced about 0.48% of output power.

  • PDF

자동차용 모듈화 도어의 동특성 분석에 관한 연구 (A Study on the Dynamic Characteristics of Door Module for Vehicle)

  • 배철용;김찬중;권성진;이봉현;장운성;이준우
    • 한국소음진동공학회논문집
    • /
    • 제17권11호
    • /
    • pp.1093-1101
    • /
    • 2007
  • This study presents the design improvement process for door module. Its objective evades the resonance generated at module plate due to the operation of window regulator motor. For this study, the design improvement process is composed of experimental methods having three steps. First step is modal analysis at door assembly status for acquisition of dynamic characteristics which are modal frequency and damping. Second step is a vibration experiment to get the test mode considered an efficiency of window regulator motor. Last step is a vibration measurement by the form of $6{\times}6$ array on module plate. A vibration measurement of $6{\times}6$ array form can be got to three analysis results which are a transfer path of vibration using cross correlation function, a vibration map using OA level and a contribution by frequency band using coherent output power spectrum on module plate. These results are applied to SDM(structural dynamic modification) for design improvement to get around the resonance on module plate by the excitation of window regulator motor.

다층 기판 위에 표면실장된 SRAM 모듈 설계 제작 (The Design and Fabrication of SRAM Modules Surface Mounted on Multilayer Borads)

  • 김창연;지용
    • 전자공학회논문지A
    • /
    • 제32A권3호
    • /
    • pp.89-99
    • /
    • 1995
  • In this paper, we ecamined the effect that MCM-L technique influencess on the design and fabrication of multichip memory modules in increasing the packing desity of memory capacity and maximizing its electrical characteristics. For that purpose, we examined the effective methods of reducing the area of module layout and the wiring length with the variation of chip allocation and the number of wiring layers. We fabricated a 256K${\times}$8bit SRAM module with eight 32K${\times}$8bit SRAM chips. The routing experiment showed that we could optimize the area of module layout and wiring length by placing chips in a row, arranging module I/O pads parallel to chip I/O pads, and equalizing the number of terminal sides of module I/O's to that of chip I/O's. The routing was optimized when we used three wire layers in case of one sided chip mounting or five wire layers in case of double sided chip mounting. The fabricated modules showed 18.9 cm/cm$^{2}$ in wiring density, 65 % in substrate occupancy efficiency, and module substrate and functionally tested to find out the module working perfectly.

  • PDF

콘크리트 구조물에서의 열전모듈 거동에 관한 기초연구 (Fundamental Study of the Behavior of Thermoelectric Module on Concrete Structure)

  • 임치수;이재준
    • 한국도로학회논문집
    • /
    • 제17권5호
    • /
    • pp.33-38
    • /
    • 2015
  • PURPOSES : The purpose of this paper is to investigate the application of thermoelectric technology to concrete structures for harvesting solar energy that would otherwise be wasted. In various fields of research, thermoelectric technology using a thermoelectric module is being investigated for utilizing solar energy. METHODS: In our experiment, a halogen lamp was used to produce heat energy instead of the solar heat. A data logger was used to record the generated voltage over time from the thermoelectric module mounted on a concrete specimen. In order to increase the efficiency of energy harvesting, various factors such as color, architecture, and the ability to prevent heat absorption by the concrete surface were investigated for the placement of the thermoelectric module. RESULTS : The thermoelectric module produced a voltage using the temperature difference between the lower and upper sides of the module. When the concrete specimen was coated with an aluminum foil, a high electric power was measured. In addition, for the power generated at low temperatures, it was confirmed that the voltage was generated steadily. CONCLUSIONS: Thermoelectric technology for energy harvesting can be applied to concrete structures for generating electric power. The generated electricity can be used to power sensors used in structure monitoring in the future.

Investigation of EVA Accelerated Degradation Test for Silicon Photovoltaic Modules

  • Kim, Jaeun;Rabelo, Matheus;Holz, Markus;Cho, Eun-Chel;Yi, Junsin
    • 신재생에너지
    • /
    • 제17권2호
    • /
    • pp.24-31
    • /
    • 2021
  • Renewable energy has become more popular with the increase in the use of solar power. Consequently, the disposal of defective and old solar panels is gradually increasing giving rise to a new problem. Furthermore, the efficiency and power output decreases with aging. Researchers worldwide are engaged in solving this problem by developing eco-module technologies that restore and reuse the solar panels according to the defect types rather than simple disposal. The eco-module technology not only solves the environmental problem, but also has economic advantages, such as extending the module life. Replacement of encapsulants contributes to a major portion of the module maintenance plan, as the degradation of encapsulants accounts for 60% of the problems found in modules over the past years. However, the current International Electrotechnical Commission (IEC) standard testing was designed for the commercialization of solar modules. As the problem caused by long-term use is not considered, this method is not suitable for the quality assurance evaluation of the eco-module. Therefore, to design a new accelerated test, this paper provides an overview of EVA degradation and comparison with the IEC and accelerated tests.

비행 절차에 따른 항공기 소음 분석용 INM 입력 자료 생성 모듈 설계 (Design of INM Input Generation Module for Aircraft Noise Analysis with Flight Procedures)

  • 최철희;은연주;전대근;전향식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.178-182
    • /
    • 2012
  • PEAT(Procedure/airspace Efficiency Assessment Tool)는 비행절차 및 공역 설계 프로그램을 이용하여 설계된 비행절차에 대해, 연료소모, 비행시간, 비행적합성, 소음분석 등의 효율성을 평가한다. 이 중 본 연구에서는 소음 분포 해석을 위한 INM(Integrate Noise Model)의 입력 자료를 생성하는 모듈을 설계하였다. 소음 분포 해석을 위한 INM 입력 파일은 항공기 기종, 소음 모델, 공항 환경, 활주로 트랙, 항공기 운항 횟수, 비행로 등에 관한 데이터를 담고 있어야 하며, 본래 파일 형태의 입력으로 구동하도록 설계되어 있지 않은 INM의 특성상 적절한 파일 형식을 만족시켜야 하는 구속조건 또한 뒤따른다. 따라서 입력될 데이터는 원래 주어진 확장성 마크업 언어(XML)에서 데이터베이스파일(DBF) 변환되도록 설계하였으며, 본 논문에서는 INM의 입력 자료를 제공하고 INM의 소음 분석 결과를 변환하여 저장하는 기능을 갖는 모듈의 설계 결과를 제시한다.

  • PDF

함정용 다기능 AESA 레이더 시스템을 위한 고전압·고효율 DC-DC 전원모듈 개발 (Development of High Voltage, High Efficiency DC-DC Power Module for Modern Shipboard Multi-Function AESA Radar Systems)

  • 정민길;이원영;김상근;김수태;권영수
    • 한국군사과학기술학회지
    • /
    • 제24권1호
    • /
    • pp.50-60
    • /
    • 2021
  • For conventional AESA radars, DC-DC power modules using 300 Vdc have low efficiency, high volume, heavy weight, and high price, which have problems in modularity with T/R module groups. In this paper, to improve these problems, we propose a distributed DC-DC power module with high-voltage 800 Vdc and high-efficiency Step-down Converter. In particular, power requirements for modern and future marine weapons systems and sensors are rapidly evolving into high-energy and high-voltage power systems. The power distribution of the next generation Navy AESA radar antenna is under development with 1000 Vdc. In this paper, the proposed highvoltage, high-efficiency DC-DC power modules increase space(size), weight, power and cooling(SWaP-C) margins, reduce integration costs/risk, and reduce maintenance costs. Reduced system weight and higher reliability are achieved in navy and ground AESA systems. In addition, the proposed architecture will be easier to scale with larger shipboard radars and applicable to other platforms.

표준기상 데이터와 열해석을 이용한 태양광열 모듈의 필요 냉각수량 산출 (Calculation of Required Coolant Flow Rate for Photovoltaic-thermal Module Using Standard Meteorological Data and Thermal Analysis)

  • 이천규;정효재
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.18-22
    • /
    • 2022
  • Photovoltaics (PV) power generation efficiency is affected by meteorological factors such as temperature and wind speed. In general, it is known that the power generation amount decreases because photovoltaics panel temperature rises and the power generation efficiency decreases in summer. Photovoltaics Thermal (PVT) power generation has the ad-vantage of being able to produce heat together with power, as well as preventing the reduction in power generation efficien-cy and output due to the temperature rise of the panel. In this study, the amount of heat collected by season and time was calculated for photovoltaics thermal modules using the International Weather for Energy Calculations (IWEC) data provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). Based on this, we propose a method of predicting the temperature of the photovoltaics panel using thermal analysis and then calculating the flow rate of coolant to improve power generation efficiency. As the results, the photovoltaics efficiencies versus time on January, April, July, and October in Jeju of the Republic of Korea were calculated to the range of 15.06% to 17.83%, and the maxi-mum cooling load and flow rate for the photovoltaics thermal module were calculated to 121.16 W and 45 cc/min, respec-tively. Though this study, it could be concluded that the photovoltaics thermal system can be composed of up to 53 modules with targeting the Jeju, since the maximum capacity of the coolant circulation pump of the photovoltaics thermal system applied in this study is 2,400 cc/min.