• Title/Summary/Keyword: modular steel building

Search Result 47, Processing Time 0.024 seconds

A Experimental Study on Structural Behavior of Hybrid Precast Concrete Panel (복합 프리캐스트 콘크리트 패널의 구조 거동에 대한 실험적 연구)

  • Lee, Sang-Sup;Park, Keum-Sung
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.9
    • /
    • pp.11-18
    • /
    • 2018
  • As the height of the modular buildings increases, their stability becomes more and more dependent on the core. All traditional construction methods in structural concrete and steel can be utilized for cores in modular buildings but a core system with dry connection is more desirable to complete a greater degree of factory finish and faster erection of modular buildings. In order to do that, the hybrid PC(precast concrete) panel, which has a pair of C-shaped steel beams combined at the top and bottom of a concrete wall, was developed, In this study the cyclic lateral loading test on the hybrid PC panel is carried out and the panel configurations are examined to enhance the structural performance in comparison with the RC wall. Experimental results show that the strength of hybrid PC panel is about 70% of thar ot RC wall and the anchorage of vertical reinforcing bar welded to C-shaped steel beam needs to be improved.

Experimental Study on the Cyclic Behavior of Modular Building with Strap Braced Load Bearing Steel Stud Walls (스트랩 브레이스를 갖는 내력벽식 모듈러건축 스틸스터드 벽체의 반복하중에 대한 거동 연구)

  • Lee, Doo Yong;Cho, Bong Ho;Kim, Tae Hyeong;Ha, Tae Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.6
    • /
    • pp.415-425
    • /
    • 2016
  • Load-bearing steel stud wall system is widely used for the middle-to-high rise modular buildings worldwide. Seismic performance is a key issue to apply load-bearing steel stud wall system to modular buildings in Korea. This study proposes a new strap braced steel stud wall system with enhanced seismic performance and design equations considering the flexural behaviour of the vertical outer studs. For the verification, two specimens with different strap braces and vertical outer stud were designed and tested. The test results showed that the total strengths were evaluated to be 1.11 to 1.18 times higher than the predicted values. Usually strap braced walls are considered to have low energy dissipation capacities. The proposed system showed enhanced seismic performance with equivalent damping of 9.42% due to the reduced pinching effects.

Lateral-resisting Structural Systems for Tall Modular Buildings (모듈러 건축물의 수평력 저항 구조시스템)

  • Lee, Chang-Hwan;Chung, Kwang-Ryang
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.79-88
    • /
    • 2016
  • Modular buildings are constructed by assembling modular units which are prefabricated in a factory and delivered to the site. However, due to a problem of noise between floors, concrete slab is usually poured at the top or bottom level of a modular unit in Korea. This greatly increases the weight of buildings, but designing vertical members of modular units to resist overall gravity loads is very inefficient. In this study, considering domestic building construction practices, feasible structural systems for tall modular buildings are proposed in which separate steel frames and reinforced concrete core walls are designed to resist gravity and lateral loads. To verify performance, a three-dimensional structural analysis has been performed with two types of prototype buildings, i.e., a residential building and a hotel. From the results, wind-induced lateral displacements and seismic story drifts are examined and compared with their limit values. Between the two kinds of buildings, the efficiency of the proposed system is also evaluated through a comparison of the weight of structural components. Finally, the effect of a floor diaphragm on the overall behavior is analyzed and discussed.

Lateral stiffness of corner-supported steel modular frame with splice connection

  • Yi-Fan Lyu;Guo-Qiang Li;Ke Cao;Si-Yuan Zhai;De-Yang Kong;Xuan-Yi Xue;Heng Li
    • Steel and Composite Structures
    • /
    • v.48 no.3
    • /
    • pp.321-333
    • /
    • 2023
  • This paper proposes a comprehensive investigation on lateral stiffness of corner-supported steel modular frame using splice connection. A full-scale modular frame with two stacked steel modules under lateral load is tested. Ductile pattern in the transfer of lateral load is found in the final failure mode. Two types of lateral stiffness, including tangent stiffness and secant stiffness, are defined from the load-displacement due to the observed nonlinearity. The difference between these two types of stiffness is found around 20%. The comparisons between the experimental lateral stiffness and the predictions of classical methods are also conducted. The D-value method using hypothesis of independent case is a conservative option for predicting lateral stiffness, which is more recommended than method of contraflexural bending moment. Analyses on two classical short-rod models, including fix-rod model and pin-rod model, are further conducted. Results indicate that fix-rod model is more recommended than pin-rod model to simplify splice connection for simulation on lateral stiffness of modular frame in elastic design stage.

Structural Performance Evaluation for Composite Beam Member of Hybrid Modules Frame with Steel-Precast Concrete (강-PC 복합모듈러 골조의 합성보에 대한 구조성능 평가)

  • Lee, Sang Sup;Park, Keum Sung;Bae, Kyu Woong;Choi, Yoon Chul
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.5
    • /
    • pp.331-340
    • /
    • 2017
  • This study was performed in order to develop of the new modular construction system. For the modular construction method that is currently applied in the country, it is very expensive in terms of material costs and fire resistance because it uses only the steel C-type beam. In order to overcome this, and the practical application of new steel-PC hybrid module construction system. Improvement and development of the cross-section of the structural beam member in order to be carried out first. An experiment was carried out by making three specimens. Experiment result, the composite beam was dominated by the horizontal shear failure. It was evaluated through a nonlinear analysis and experimental & theoretical for the structural performance the composite beam member.

4th Industrial Revolution Construction and Machinery Covergence Technology base Rotational Modular Housing of CFT Central Axis Structure (4차산업혁명 건설 및 기계 융합기술기반 CFT 중심축 구조체의 회전형 모듈러주택)

  • Kim, Dae-Geon;Woo, Jong-Yeol;Woo, A-Jin;Jeon, ho gyeong;Hong, young ju;Lee, Dong-Oun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.179-180
    • /
    • 2018
  • This study aims to provide a more comfortable environment for the external environment by designing a rotable dwelling that deviates from the conventional fixed residential concept. The round pillars, which are the center of the building, are constructed by placing the CFT (concrete Filled steel Tube) technique in place and assembling modular houses with columns. This study combines existing building techniques. Korea also needs to develop various related studies quickly.

  • PDF

Development of Hybrid Panel with C-shaped Steel Beam at Top and Bottom of Precast Concrete Wall (프리캐스트 콘크리트 벽체의 상하부에 C형강 보가 결합된 복합 패널의 개발)

  • Lee, Sang Sup;Park, Keum Sung
    • Journal of Korean Society of Steel Construction
    • /
    • v.29 no.6
    • /
    • pp.435-442
    • /
    • 2017
  • A lateral load resisting system is a necessary structural element for the mid- to high-rise modular buildings and concrete cores are known as the most typical lateral load resisting systems in 10- to 20-story modular buildings. It is difficult to construct a concrete core simultaneously with the installation and finishing work of modular units because concrete placed using wet methods might contaminate or destroy the modular unit. Therefore, we have developed a hybrid PC (precast concrete) panel construction method that can construct a concrete core together with the installation of modular units. The hybrid PC panel is a load-bearing element in which a pair of C-shaped beams are combined at the top and bottom of a concrete wall. Concrete cores can be constructed by dry method to connect the hybrid PC panels with bolts. In this study, the details and connection of hybrid PC panels are improved to have the lateral performance comparable to reinforced concrete structural walls and are verified through FE analysis.

Analytical Models of Beam-Column joints in a Unit Modular Frame (단위 모듈러 구조체의 보-기둥 접합부 해석 모델)

  • Choi, Kyung-Suk;Kim, Hyung-Joon
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.6
    • /
    • pp.663-672
    • /
    • 2014
  • Recently, modular structural systems have been applicable to building construction since they can significantly reduce building construction time. They consists of several unit modular frames of which each beam-column joint employs an access hole for connecting unit modular frames. Their structural design is usually carried out under the assumption that their load-carrying mechanism is similar to that of a traditional steel moment-resisting system. In order to obtain the validation of this assumption, the cyclic characteristics of beam-column joints in a unit modular frame should be investigate. This study carried out finite element analyses(FEM) of unit modular frames to investigate the cyclic behavior of beam-column joints with the structural influence of access holes. Analysis results show that the unit modular frames present stable cyclic response with large deformation capacities and their joints are classified into partial moment connections. Also, this study develops a simple spring model for earthquake nonlinear analyses and suggests the Ramberg-Osgood hysteretic rule to capture the cyclic response of unit modular frames.

IFC-based Representation Method of Part Information in Superstructure Module of Modular Steel Bridge with Assembly System (모듈러 강교량 상부모듈의 조립체계 정의를 통한 IFC 기반의 부품정보 표현방법)

  • An, Hyun Jung;Lee, Sang-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.307-314
    • /
    • 2012
  • IFC-based representation method of part library for superstructure module of modular steel bridge is proposed. The library is capable of efficiently offering and exchanging part information in process of manufacture, assembly, design, and construction of modular steel bridge. Entities, representing physical part information in IFC model, are matched semantically with parts of the superstructure module for representation of part information with IFC model. Either types of matched entities are applied in order to verify the role of each part, or new types are defined as a user-defined types. In addition, assembly system has been classified and defined into 4 levels of LoD(Level of Detail) to provide appropriate part information efficiently from the part library in each step of the process. Then, new property is defined for representing the LoD information with IFC Model. Finally, IFC-based test library of modular steel bridge is generated by applying the matched entities and entity types to the actual the superstructure module of modular steel bridge.

Behavior of C-Shaped Beam to Square Hollow Section Column Connection in Modular Frame (모듈러 골조의 각형강관 기둥과 C형강 보 접합부의 거동 평가)

  • Lee, Sang Sup;Park, Keum Sung;Hong, Sung Yub;Bae, Kyu Woong
    • Journal of Korean Society of Steel Construction
    • /
    • v.27 no.5
    • /
    • pp.471-481
    • /
    • 2015
  • Modular building is a prefabricated construction system for building where factory-produced pre-engineered modular units are delivered to site and assembled as substantial elements of a building. There are two basic kinds of modular structures. One is a load-bearing wall structure designed to transfer the load through longitudinal walls. The other is a frame structure composed of columns and beams. For frame structure, square hollow section is often used as a column member and channel as a beam member in modular unit. Lower and upper modules are fasten with bolts via a pre-installed access hole in the SHS column. However, the access holes can weaken the panel zone that would affect the behavior of beam to column connection. The 5 specimens of beam to column connections with parameters of access hole, column thickness and diaphragm were made and this paper describes the test results.