  • This paper presents the design, fabrication sequence and measurement results of a highly sensitive capacitive-type humidity sensor using a polyimide film without hydrophobic elements. The structure of the humidity sensor is MIM (metalinsulator-metal). For a high sensitivity, a modified aromatic polyimides as a moisture absorbing layer has been synthesized instead of using general polyimides containing hydrophobic elements. The polyimide film was obtained by synthesizing and thermally polymerizing polyamic acid composed of m-pyromellitic dianhydride, phenelenediamine and dimethylacetamide. Characteristics of fabricated sensors which include sensitivity, hysteresis and stability have been measured. The measurement result shows the percent normalized capacitance change of 0.37/%RH over a range from 10 to 90%RH, hysteresis of 0.77% over the same %RH range and maximum drift of 0.25% at 50%RH. The result shows that the developed humidity sensor can be applied to evaluate a hermeticity of various sensors and actuator systems as well as micro packages.