• Title/Summary/Keyword: modified PET

Search Result 90, Processing Time 0.025 seconds

Core-shell TiO2/Ag Nanoparticle Synthesis and Characterization for Conductive Paste (전도성 페이스트용 코어-쉘 TiO2/Ag 나노입자의 합성 및 특성 연구)

  • Sang-Bo, Sim;Jong-Dae, Han
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.36-44
    • /
    • 2023
  • Core-shell TiO2/Ag nanoparticles were synthesized by a modified sol-gel process and the reverse micelle method using acetoxime as a reducing agent in water/dodecylbenzenesulfonic acid (DDBA)/cyclohexane. The structure, shape, and size of the TiO2/Ag nanoparticles were investigated using X-ray diffraction (XRD), UV-visible spectroscopy, scanning electron microscope (SEM), transmission electron microscope (TEM), and thermogravimetric analysis (TGA). The size of TiO2/Ag nanoparticles could be controlled by changing the [water]/[DDBA] molar ratio values. The size and the polydispersity of TiO2/Ag nanoparticles increased when the [water]/[DDBA] molar ratio rose. The resultant Ag nanoparticles over the anatase crystal TiO2 nanoparticles exhibited a strong surface plasmon resonance (SPR) peak at about 430 nm. The SPR peak shifted to the red side with the increase in nanoparticle size. Conductive pastes with 70 wt% TiO2/Ag nanoparticles were prepared, and the pastes were coated on the PET films using a screen-printing method. The printed paste films of the TiO2/Ag nanoparticles demonstrated greater surface resistance than conventional Ag paste in the range of 405~630 μΩ/sq.

A Case of Recurrent Papillary Thyroid Carcinoma with Adrenal Metastasis (재발 유두 갑상선암의 부신전이 1예)

  • Kim, Chang-Woo;Yun, Ji-Sup;Lee, Yong-Sang;Nam, Kee-Hyun;Chung, Woong-Youn;Hong, Soon-Won;Park, Cheong-Soo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.23 no.1
    • /
    • pp.50-53
    • /
    • 2007
  • Adrenal metastasis from papillary thyroid carcinoma is extremely rare. We present herein a patient with adrenal metastases from recurrent papillary carcinoma of the thyroid. A 54 year-old woman had received a total thyroidectomy and postoperative radioactive iodine therapy for locally advanced papillary thyroid carcinoma. One year after initial surgery, distant metastases to multiple organs including right cervical lymph nodes, left upper lung, left 2nd and 3rd ribs, 2nd thoracic vertebra and left adrenal gland were found by 18-FDG-PET-CT whole body scan. She underwent right modified neck dissection, partial resection of left 2nd and 3rd ribs, posterior arch of 2nd thoracic vertebra, left upper lobectomy of lung, and left adrenalectomy. On histologic examination, metastases to the left adrenal gland and cervical lymph nodes were papillary thyroid carcinomas, while other metastatic sites turned out to be anaplastic thyroid carcinomas. Despite aggressive surgery and postoperative adjuvant therapy, her general clinical conditions were getting worse day by day due to regrowing of the anaplastic thyroid carcinomas. To our knowledge, this is the first case reported in Korea.

Assessment of chemical purity of [13N]ammonia injection: Identification of aluminium ion concentration

  • Kim, Ho Young;Park, Jongbum;Lee, Ji Youn;Lee, Yun-Sang;Jeong, Jae Min
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.4 no.2
    • /
    • pp.80-84
    • /
    • 2018
  • $[^{13}N]$Ammonia or $[^{13}N]NH_3$ is one of the most widely used PET tracer for the measurement of MBF. To produce $[^{13}N]NH_3$, devarda's alloy which contains aluminum, copper and zinc is used for the purpose of reduction from $^{13}N$-nitrate/nitrite to $[^{13}N]NH_3$. Since aluminum has neurotoxicity and renal toxicity, the amount of it should be carefully limited for the administration to the human body. Although USP and EP provide a way to identify the aluminum ion concentration, there are some difficulties to perform. Therefore, we tried to develop the modified method for verifying aluminum concentration of test solution. We compared color between test and standard solutions using chrome azurol S in pH 4.6 acetate buffer. We also tested color change of test and standard solutions according to pH, amounts and the order of reagent and time difference These results demonstrated that the color change of the solution can reflect quantitatively measure aluminum ion concentration. We hope the method is to be used effectively and practically in many sites where $[^{13}N]NH_3$ is produced.

Current Postharvest Management and Packaging Technology of Strawberries in Korea (국내 딸기의 수확 후 관리와 포장기술 현황)

  • Lee, Seongmin;Park, Insik;Chung, Dae-Sung;Jeong, Cheon Soon;Lee, Youn Suk
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.1
    • /
    • pp.17-24
    • /
    • 2014
  • The purpose of this study was to review the brief physiological characteristics and some factors of the quality decay of strawberry harvested in Korea. Strawberries are highly perishable with soft surface. Surface injury and fungus growth are common as a result of handling and distribution. Many growers and distributers are considered to protect the physical impact and inhibit the fungus growth for prolonging the shelf life in the distribution and market channels. Post-harvest treatments of precooling, carbon dioxide, chlorine dioxide, ozone, and ultrasound are practiced on strawberry in order to extend shelf-life and preserve the quality. Modified atmosphere packaging, edible coating, and oxygen absorbent application can be used as supplemental treatments to extend postharvest-life of strawberry. The packaging types for current domestic and export strawberry in Korea were summarized. The findings from this study can be lead to a better understanding of strawberry packaging development associated with the proper handling and distribution of strawberry. This could be useful for the strawberry growers, distributors, and buyers.

  • PDF

Storage Quality of Sulhyang Strawberries as Affected by High O2 Atmosphere Packaging (고산소 환경기체조절 포장조건에 따른 설향 딸기의 저장 중 품질변화)

  • Lee, Hyun-Hee;Hong, Seok-In;Kim, Dongman
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.2
    • /
    • pp.191-198
    • /
    • 2013
  • The storage quality of fresh Sulhyang strawberries packaged under modified atmospheres was investigated to examine the effect of high $O_2$ on the fruit. Fresh strawberries were packed into PP trays and top-sealed with PET/PP film. Initial gas compositions inside the packages were varied with air, 40% $O_2$/60% $N_2$, 60% $O_2$/40% $N_2$, and 80% $O_2$/20% $N_2$. Sealed packages in PE film bags with air and perforated PP trays were also used as another treatment and control, respectively. Quality attributes and viable cell counts of pathogenic bacteria were assessed during storage at $5^{\circ}C$ for 12 days. High $O_2$ concentration showed no significant effects on the physicochemical and microbial qualities of strawberries. Fruit packaged in PE film bags with 6-15% $O_2$ and 7-9% $CO_2$ during storage had the lowest viable cell counts of inherent microorganisms among the treatment samples. Growth of pathogenic bacteria was suppressed in perforated packages where molds occurred frequently. In an overall sensory aspect, the PE film packages exhibited higher scores than the others at the end of storage period. The experimental results suggested that gas-permeable film packaging with an appropriate combination of $O_2$ and $CO_2$ rather than gas-barrier tray packaging with an initially high $O_2$ concentration would be suitable for improving the storability of strawberries.

Effect of Selenium on Internal Quality of Basil (Ocimum basilicum L.) During Storage (Basil 양액재배 시 Selenium 첨가가 저장 중 품질에 미치는 영향)

  • 박권우;김민순;강호민;이문정
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.193-200
    • /
    • 2000
  • The object of this study is to investigate the quality change of sweet basil grown with selenium(Se) in hydroponic culture. Sweet basil was cultured with 1 fold herb nutrient solution as suggested by European vegetable R & D Center in Belgium. Before three weeks harvest, sodium selenate(N $a_2$Se $O_4$) was supplied to 2 and 4 mg. $L^{-1}$ in the nutrient solution. Sweet basil was stored at 1$0^{\circ}C$ using 40um ceramic film and PET (polyethylene terephalate) for 15 days in modified atmosphere(MA) storage condition. The weight loss of sweet basil was higher in non-treatment compared to Se treatments in both of two films but it was decreased over 5% in PET treatment. Se concentrations in leaf tissues increased in the response to the treated levels of N $a_2$Se $O_4$concentrations, and this tendency was appeared similar results after storage. There was no significant effect of packing materials on volatilization of Se in sweet basil. The total chlorophyll and essential oil content was increased with increasing N $a_2$Se $O_4$concentration in nutrient solution. The amount of volatilization flavor was not higher at N $a_2$Se $O_4$4mg. $L^{-1}$ treatment compare to others during storage. Se content was 112.73 ug. $g^{-1}$ dry mass at 2 mg. $L^{-1}$ treatment before storage and the decrease of Se content was observed by 50% at 15 days after storage. The condition, which N $a_2$Se $O_4$2mg. $L^{-1}$$^{plement}$ in nutrient solution during growth stage and stored with 40um ceramic film on 1$0^{\circ}C$are acceptable for maintaining of sweet basil quality. Moreover it can be a proper Se concentration for human health. Overall, Se treatment in nutrient solution has effect on promoting and maintaining quality of herb during storage life. Also, there was not significant change of essential oil compounds by volatilization of Se.mpounds by volatilization of Se.

  • PDF

Applications of Functional Tray Form Packaging to Extend the Freshness of High-Quality 'Fuji' Apples (특 등급 품질 후지사과 선도유지를 위한 플라스틱 용기 포장 효과 연구)

  • Chung, Dae-Sung;Lee, Youn-Suk
    • Food Science and Preservation
    • /
    • v.16 no.6
    • /
    • pp.817-823
    • /
    • 2009
  • We investigated the effects of storage temperature and packaging treatment on the freshness of high-quality 'Fuji' apples to improve consumer confidence in the maintenance of high fruit quality during distribution. A 0.35 mm-deep PET tray form-sealed with a 0.05 mm LDPE film lid was developed and tested with the aim of optimizing gas composition within the package headspace to utilize potential modified atmosphere (MA) storage to maintain the freshness of apples. Weight loss, color difference, firmness, respiration rate, gas concentrations in packages, acidity, solid soluble content, and fruit decay rate were measured during storage at $5^{\circ}C$ and $25^{\circ}C$. The results showed that respiration rate, weight loss, color difference, and firmness were lower and overall quality better during storage at $5^{\circ}C$ compared with $25^{\circ}C$. Also, the fruits packed in the functional tray form showed a low level of quality changes compared with the control (no packaging). The accumulated gasconcentrations in the headspace of the packages decreased from 21% to 12% $O_2$ and increased from 0% to 5% $CO_2$ (v/v) on day 7, and after remained at those levels thereafter. Soluble solid contents and total acidities of the packaged fruits were in the range of $11\;-\;14^{\circ}Brix$ and 0.2 0.3% during storage. Decay rates in the control and packaged fruits were more than 20% and less than 10% at 3 weeks, respectively. Based on the standard acceptable level (less than 10%) of total weight loss, it could be estimated that the shelf life of top-quality fruits packed in functional trays was 3 weeks at $5^{\circ}C$ and 16 weeks at $25^{\circ}C$, whereas the shelf life of the control fruit was 1 week and 12 weeks, respectively. For the top-quality fruit "Fuji" apples, the best results were obtained with a functional tray form for packaging treatment and a storage temperature of $5^{\circ}C$.

Production of $^{11}C$ labeled Radiopharmaceuticals using $[^{11}C]CO_2$ Produced in the KOTRON-13 (한국형 사이클로트론(KOTRON-13)을 이용한 $[^{11}C]CO_2$ 생산과 다양한 $^{11}C$-표지 방사성의약품 생산 적용)

  • Lee, Hong Jin;Park, Jun Hyung;Moon, Byung Seok;Lee, In Won;Lee, Byung Chul;Kim, Sang Eun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.106-109
    • /
    • 2012
  • Purpose : The KOTRON-13 cyclotron was developed and installed in regional cyclotron centers to produce short-lifetime medical radioisotopes. However, this cyclotron has limited capacity to produce $^{11}C$ so far. In present study, we developed an effective $^{11}C$ target system combining with fluorine-18 target and applied to the production of various $^{11}C$ radiopharmaceuticals. Materials and Methods : To develop the optimal $^{11}C$ target system and effective its cooling system, we designed the $^{11}C$ target system by Stopping and Range of Ions in Matter (SRIM) simulation program and considered the cavity pressure during irradiation at target grid. In this investigation, we modified target materials, cavity shapes and the position of cooling system in $^{11}C$ target and then evaluated $[^{11}C]CO_2$ production at different beam currents, thickness of the target foil, oxygen content of nitrogen gas and target gas loading pressure. Also, we evaluate the production of several $^{11}C$ radiopharmaceuticals such as [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine. Results : $[^{11}C]CO_2$ was produced about 74 GBq for 30min irradiation at 60 ${\mu}A$ of beam current as following conditions: thickness of the target foil: 19 nm HAVAR, oxygen content of nitrogen: under 50 ppb, target gas loading pressure: 24 bar. Additionally, the cooling system was stable to produce $[^{11}C]CO_2$ at high beam current. The radiochemical yields of [$^{11}C$]PIB, [$^{11}C$]DASB, and [$^{11}C$]Clozapine showed about 26-38% with over 127 GBq/umol of specific activity. Conclusion : The carbon-11 target system in the KOTRON-13 cyclotron was successfully developed and showed stable production of $[^{11}C]CO_2$. These results showed that our $^{11}C$ target system will be compatible with other commercial system for the routine $^{11}C$ radiopharmaceuticals production in the KOTRON-13 cyclotron.

  • PDF

A Study on GPU-based Iterative ML-EM Reconstruction Algorithm for Emission Computed Tomographic Imaging Systems (방출단층촬영 시스템을 위한 GPU 기반 반복적 기댓값 최대화 재구성 알고리즘 연구)

  • Ha, Woo-Seok;Kim, Soo-Mee;Park, Min-Jae;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.459-467
    • /
    • 2009
  • Purpose: The maximum likelihood-expectation maximization (ML-EM) is the statistical reconstruction algorithm derived from probabilistic model of the emission and detection processes. Although the ML-EM has many advantages in accuracy and utility, the use of the ML-EM is limited due to the computational burden of iterating processing on a CPU (central processing unit). In this study, we developed a parallel computing technique on GPU (graphic processing unit) for ML-EM algorithm. Materials and Methods: Using Geforce 9800 GTX+ graphic card and CUDA (compute unified device architecture) the projection and backprojection in ML-EM algorithm were parallelized by NVIDIA's technology. The time delay on computations for projection, errors between measured and estimated data and backprojection in an iteration were measured. Total time included the latency in data transmission between RAM and GPU memory. Results: The total computation time of the CPU- and GPU-based ML-EM with 32 iterations were 3.83 and 0.26 see, respectively. In this case, the computing speed was improved about 15 times on GPU. When the number of iterations increased into 1024, the CPU- and GPU-based computing took totally 18 min and 8 see, respectively. The improvement was about 135 times and was caused by delay on CPU-based computing after certain iterations. On the other hand, the GPU-based computation provided very small variation on time delay per iteration due to use of shared memory. Conclusion: The GPU-based parallel computation for ML-EM improved significantly the computing speed and stability. The developed GPU-based ML-EM algorithm could be easily modified for some other imaging geometries.

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF