• 제목/요약/키워드: model scanner

검색결과 394건 처리시간 0.027초

자유 곡면 생성을 통한 역공학 적용에 관한 연구 (Study on Application of Reverse Engineering by Generation of the Free-Form Surface)

  • 허성민;최재원;이석희
    • 한국정밀공학회지
    • /
    • 제18권10호
    • /
    • pp.168-177
    • /
    • 2001
  • Reverse engineering has been widely used for the shape reconstruction of an object without CAD data and the measurement of clay or wood models fur the development of new products. To generate a surface from measured points by a laser scanner, typical steps include the scanning of a clay or wood model, the generation of compatible input curves, the generation of a surface and manufacturing data like G code or STL file. A laser scanner has a great potential to get geometrical data of a model for its frost measuring speed and higher precision. The data from a laser scanner are composed of many line stripes of points including small spikes and noise. A new approach using automated surface generating algorithm is introduced to deal with problems during reverse engineering process. And the input data and the generated surface are represented in IGES format, thus can be supplied to other CAD/CAM software without any data manipulation.

  • PDF

접촉식 3차원 형상스캐너를 이용한 터빈 블레이드의 형상 정밀도 측정 (Profile Error Measurement of a Turbine Blade Using a Contact Type 3D-Scanner)

  • 강병수;강재관
    • 한국공작기계학회논문집
    • /
    • 제15권6호
    • /
    • pp.76-81
    • /
    • 2006
  • In this paper, profile error measurement method of a turbine blade using 3D-scanner is developed. The method begins with scanning the upper and lower sides of the blade on which three small balls are attached, and constructs a solid measurement model by registering the two scanned surfaces. Airfoils are derived from the model at each interval by intersecting it with a plane, and arranged with design airfoils. The $2^2$ factorial design search method is engaged in arranging the two airfoils, from which the main blade parameters including the edge radius are computed. The developed measurement technique is applied to practical blade manufacturing and validates its effectiveness.

동영상 촬영방식의 구강스캐너로 채득된 전악치열 디지털모형의 정확도 분석 : CS-3600 시스템을 중심으로 (Accuracy of full arch digital model obtained from rendering-based intraoral scanner(IOS) : An example of CS-3600 system)

  • 김재홍
    • 대한치과기공학회지
    • /
    • 제42권1호
    • /
    • pp.17-25
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate and compare the accuracy of definitive casts that are fabricated from digital intraoral impression and conventional impression technique. Methods: A master model(ANNA-4, Frasaco GmbH, Tettnang, Germany) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CS-3600 intraoral scanner(n=10). Six linear measurements were recorded between landmarks, directly on each of the stone models on two occasions by a single examiner. Measurements were made with a digital caliper to the nearest 0.01mm from manual models and with the software(Delcam PowerSHAPE) from the virtual models. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed good reliability. The ICC of the two models were 0.88~0.91(stone model) and 0.94~0.99(digital model). The mean differences to master model for stone model and digital model were 0.10~0.14mm, and 0.14~0.20mm, respectively. Conclusion: The definitive casts obtained with digital intraoral technique model had significantly larger dimensions as compared to those of the stone model. However, the differences to the master model detected appear to provide enough accuracy and reliability for clinical application.

치과용 모형재 색상에 따른 디지털 모형의 체적 안정성 연구 (The study on the dimensional stability of digitized dental stone replicas according to difference color of gypsum materials)

  • 최석순;김기백;이경탁;전진훈;김재홍
    • 대한치과기공학회지
    • /
    • 제34권4호
    • /
    • pp.369-377
    • /
    • 2012
  • Purpose: The aim of study was to compare the dimensional stability of digitized dental stone replica using different color of gypsum materials using a white light scanner with three-dimensional software. Methods: A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Several type IV stones(white, yellow, green) were used for 30 stone casts(10 casts each) duplicated a master model of mandible. The master model and the replicas were digitized with the non-contacting white light scanner to create 3-dimensional digital models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad$^{(R)}$(Delcam plc, UK) 3D graphic software. One-way analysis of variance(ANOVA) combined with a Tukey multiple-range test were used to analysis the data(${\alpha}$=0.05). Results: There were considerable differences in mean values between gypsum materials within each color(white, yellow, green), and this difference was statistically significant, p=0.001. Conclusion: Digitization of dental materials on optical scanner was affected by color. Three different color of gypsum materials showed clinically acceptable accuracies of full arch digital model produced by them. Besides, these results will have to be confirmed in further clinical studies.

Clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement: A preliminary study

  • Yun, Dalsun;Choi, Dong-Soon;Jang, Insan;Cha, Bong-Kuen
    • 대한치과교정학회지
    • /
    • 제48권4호
    • /
    • pp.262-267
    • /
    • 2018
  • The aim of this study was to test the clinical application of an intraoral scanner for serial evaluation of orthodontic tooth movement. The maxillary dentitions of eight patients with fixed orthodontic appliances were scanned using an intraoral scanner at the beginning of treatment (T0), and at 1 month (T1), 2 months (T2), 3 months (T3), and 4 months (T4) after T0. The serial digital models were superimposed on the palatal surface as a reference area, and the linear and angular changes of the central incisors, canines, and first molars were evaluated. The intraclass correlation coefficient and method errors showed that this method was clinically acceptable. Various types of orthodontic tooth movements, including minute movements, could be observed every month. The intraoral scanner and digital superimposition technique enabled the serial evaluation of orthodontic tooth movement without taking serial impressions and/or acquiring radiographs.

단속형 가변적층쾌속조형공정을 이용한 3차원 스캔데이터로부터 3차원 시작품의 쾌속 제작 (Rapid Manufacturing of 3D Prototype from 3D scan data using VLM-ST)

  • 이상호;안동규;김효찬;양동열;박두섭;채희창
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.536-539
    • /
    • 2002
  • The reverse engineering (RE) technology can quickly generate 3D point cloud data of an object by capturing the surface of a model using a 3D scanner. In the rapid prototyping (RP) technology, prototypes are rapidly produced from 3D CAD models in a layer-by-layer additive basis. In this paper, a physical human head shape is duplicated using a new RP process, the Transfer-type Variable Lamination Manufacturing process using expandable polystyrene foam sheet (VLM-ST), after the point cloud data of a human head shape measured from 3D SNX scanner are converted to STL file. From the duplicated human head shape, it has been shown that the VLM-ST process in connection with the 3D scanner is a fast and efficient process in that shapes with free surface, such as the human head shape, can be duplicated with ease. Considering the measurement time and the shape duplication time, the use of 3D SNX scanner and the VLM-ST process is expected to reduce the lead-time fur the development of new products in comparison with the other existing RE-RP connected manufacturing systems.

  • PDF

구강스캐너를 이용한 임플란트 보철물 제작 증례 (Implant prosthesis using intraoral scanner: Case Report)

  • 강병길;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제53권3호
    • /
    • pp.256-261
    • /
    • 2015
  • 임플란트 보철물의 경우 무엇보다도 보철물의 정확성이 중요하며 이러한 이유로 인해 인상채득의 정확성을 확인하는 과정이 필수적이다. 그러나 인상재 자체의 오차가 존재하며 모형을 제작하는 과정에서도 오차가 발생하게 된다. 이에 대한 대안으로 구강스캐너를 통한 보철물 제작을 생각해 볼 수 있으며, 최근 구강스캐너와 기존의 인상법 간의 정확성에 있어 통계적으로 유의할만할 차이가 없다는 많은 문헌들이 발표되었다. 따라서 intraoral scanner를 이용하여 기존에 방법에 비해 보다 편하고, 빠르며, 정확한 임플란트 보철물을 제작하는 일련의 과정을 보고하고자 한다.

Development of Color 3D Scanner Using Laser Structured-light Imaging Method

  • Ko, Youngjun;Yi, Sooyeong
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.554-562
    • /
    • 2018
  • This study presents a color 3D scanner based on the laser structured-light imaging method that can simultaneously acquire 3D shape data and color of a target object using a single camera. The 3D data acquisition of the scanner is based on the structured-light imaging method, and the color data is obtained from a natural color image. Because both the laser image and the color image are acquired by the same camera, it is efficient to obtain the 3D data and the color data of a pixel by avoiding the complicated correspondence algorithm. In addition to the 3D data, the color data is helpful for enhancing the realism of an object model. The proposed scanner consists of two line lasers, a color camera, and a rotation table. The line lasers are deployed at either side of the camera to eliminate shadow areas of a target object. This study addresses the calibration methods for the parameters of the camera, the plane equations covered by the line lasers, and the center of the rotation table. Experimental results demonstrate the performance in terms of accurate color and 3D data acquisition in this study.

모델 스캐너와 구내 스캐너로 획득한 디지털 모형에서 시행한 공간 분석의 타당도, 신뢰도, 재현성 평가 (Validity, Reliability and Reproducibility of Space Analysis using Digital Model taken via Model Scanner and Intraoral Scanner: An In vivo Study)

  • 박서현;김종수;오소희
    • 대한소아치과학회지
    • /
    • 제47권2호
    • /
    • pp.176-187
    • /
    • 2020
  • 이 연구는 모델 스캐너로 석고 모형을 스캔한 디지털 모형(Model scanned digital model, MSD)과 구내 스캐너로 구강을 스캔한 디지털 모형(Intraoral scanned digital model, ISD)에서 계측한 치아 근원심 폭경(Tooth width, TW)과 치열궁 길이(Arch length, AL)의 신뢰도와 재현성, 치열궁 길이 편차(Arch length discrepancy, ALD) 분석의 타당도를 평가하였다. 만 12 - 18세의 남, 여 30명에게 석고 모형, MSD, ISD를 획득하고, 2번 계측한 TW, AL의 신뢰도는 Pearson 상관 분석, 4명의 재현성은 군간 상관 분석 그리고 TW, AL 및 ALD의 타당도는 대응표본 t검정으로 평가하였다. 결과적으로 모든 군에서 계측한 TW, AL는 높은 신뢰도와 재현성을 보였고 MSD군의 ALD분석은 적절한 타당도를 보였다. ISD 군의 TW는 가장 높은 타당도를 보인 반면에, AL와 ALD분석은 유의미하게 짧게 측정되어 낮은 타당도를 보였으므로 임상가는 디지털 모델을 이용하여 공간 분석 시행 시 이를 고려해야 할 것이다.

구조안전진단에서의 3D 레이저 스캐너 투입 성과 분석 (Analysis of 3D Laser Scanner Input Performance in Structual Safety Diagnosis)

  • 성도윤;백인수;김재준;함남혁
    • 한국BIM학회 논문집
    • /
    • 제11권3호
    • /
    • pp.34-44
    • /
    • 2021
  • This study quantitatively analyzes the work performance of the structural safety diagnosis team that diagnoses pipe racks. To this end, a method for evaluating the performance of the structural safety diagnosis team using the queuing model was proposed. For verification, the case of applying the existing method and the method of introducing a 3D laser scanner for one site was used. The period, number of people, and initial investment cost of each project were collected through interviews with case project experts. As a result of analyzing the performance of the structural safety diagnosis team using the queuing model, it was possible to confirm the probability of delay in the work of each project and the amount of delayed work. Through this, the cost (standby cost) when the project was delayed was analyzed. Finally, economic analysis was conducted in consideration of the waiting cost, labor cost, and initial investment cost. The results of this study can be used to decide whether to introduce 3D laser scanners.