• Title/Summary/Keyword: model of body

Search Result 5,019, Processing Time 0.031 seconds

Shock and vibration analysis of a tractor-trailer type vehicle system with air suspension (공기 현가 장치를 장착한 트랙터-트레일러형 차량 시스템의 충격진동 해석)

  • 김종길;하태완
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.3 no.2
    • /
    • pp.15-22
    • /
    • 2000
  • Shock and vibration characteristics of a tractor-trailer type vehicle system with air suspension and air coupler running on a single bump road are investigated. The vehicle system is modelled and solved to two types of models, i.e. rigid-multi-body and flexible-multi-body model, by ADAMS and NASTRAN software. And the shock impulse is given by a single bump model on the road. When the analysis results of the rigid-multi-body model is compared with those of the flexible-multi-body model, it is revealed that the vibration and accelerations of the latter model are more repetitive and larger than the former.

  • PDF

Primitive Body Model Encoding and Selective / Asynchronous Input-Parallel State Machine for Body Gesture Recognition (바디 제스처 인식을 위한 기초적 신체 모델 인코딩과 선택적 / 비동시적 입력을 갖는 병렬 상태 기계)

  • Kim, Juchang;Park, Jeong-Woo;Kim, Woo-Hyun;Lee, Won-Hyong;Chung, Myung-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Body gesture Recognition has been one of the interested research field for Human-Robot Interaction(HRI). Most of the conventional body gesture recognition algorithms used Hidden Markov Model(HMM) for modeling gestures which have spatio-temporal variabilities. However, HMM-based algorithms have difficulties excluding meaningless gestures. Besides, it is necessary for conventional body gesture recognition algorithms to perform gesture segmentation first, then sends the extracted gesture to the HMM for gesture recognition. This separated system causes time delay between two continuing gestures to be recognized, and it makes the system inappropriate for continuous gesture recognition. To overcome these two limitations, this paper suggests primitive body model encoding, which performs spatio/temporal quantization of motions from human body model and encodes them into predefined primitive codes for each link of a body model, and Selective/Asynchronous Input-Parallel State machine(SAI-PSM) for multiple-simultaneous gesture recognition. The experimental results showed that the proposed gesture recognition system using primitive body model encoding and SAI-PSM can exclude meaningless gestures well from the continuous body model data, while performing multiple-simultaneous gesture recognition without losing recognition rates compared to the previous HMM-based work.

Parametric Body Model Generation for Garment Drape Simulation

  • Kim, Sungmin;Park, Chang-Kyu
    • Fibers and Polymers
    • /
    • v.5 no.1
    • /
    • pp.12-18
    • /
    • 2004
  • A parametric body model generation system has been developed. Using various mathematic and geometric algorithms of this system, a three-dimensionally scanned human body can be converted into a resizable body model. Once a parametric body model is formed, its size and shape can be modified instantaneously by providing appropriate anthropometric data. To facilitate the subsequent pattern arrangement process for garment drape simulation, a bounding box generation algorithm has been developed in this study. Also the model can be converted into a set of parametric surfaces that it can also be used for three-dimensional garment pattern design system.

Detection of Foreign Body in Esophageal Foreign Body Model Using Three Dimensional Reconstruction Technique (식도 이물 모델에서 이물 탐색을 위한 삼차원 재구성법의 활용)

  • Woo, Kuk Sung;Yoo, Young Sam;Kim, Dong Won
    • Korean Journal of Bronchoesophagology
    • /
    • v.18 no.1
    • /
    • pp.13-18
    • /
    • 2012
  • Objective This study was conducted to gather basic information of 3D CT in detecting and gaining information of esophageal foreign body (FB) models. Materials and Methods The chest model was made using PVC bottle, rubber balloon and plaster. Fish bone, Persimmon stone were used to mimic foreign bodies of esophageal model. The foreign body models were inserted into the balloon removing air from it and the balloon was sealed. The esophageal FB model was inserted into the chest model. The remaining space in the chest model was filled with fish paste and water to simulate soft tissue around esophagus. CT of chest model was reconstructed three-dimensionally by Rapidia software to make images of foreign body models. The axial CT, MPR image and VOI image were compared with real foreign body materials as to shape, size, location and orientation. Results Esophageal FB models were easily made. CT data gave good 3D images and showed realistic foreign body materials. Conclusion The results indicate the usefulness of 3D CT technique to help in diagnosis of esophageal foreign body models.

  • PDF

Statistical Estimated Model of Chronological Change in Physical Growth and Development in Korean Youth(17 Years Old) - From 1983 To 1993 - (한국 청소년(만 17세) 체격의 시대적 변천에 대한 통계적 모형 추정 -1983년부터 1993년까지-)

  • 성웅현;윤석옥;윤태영;최중명;박순영
    • Korean Journal of Health Education and Promotion
    • /
    • v.12 no.2
    • /
    • pp.36-47
    • /
    • 1995
  • This research was obtained from analyzing how the physiques of the 3rd grade students of high school for males and females and developed for the last eleven years(from 1983 to 1993). By the physiques and nutritional index of physical growth and development, Relative Body Weight of 36.62 exceeded the standard, on the other hand females showed lower records than the standard. Relative Chest Girth Index belonged to the normal type of males and females in all, in the comparison of the records between 1983 and 1993, males increased in average 0.29 and females in average 0.55. Relative Chest Girth Index of females was greater than that of females. By the results of Relative Sitting Height Index, growth of the lower body for males and females was greater than that of males. In case of Vervaeck Index, males increased in average 2.04 but females increased in average 1, 20 relatively less than males. These phenomena provided for the evidence of the deficient nutrition in females. In the regression models of body height and body weight within a certain period, statistical regression model types which best indicated chronological average changes of body height and body weight, took 3rd Order Polynomial Regression Model rather than linear regression model. In females, statistical regression model types which best is suitable for chronological average change of body height and body weight, took 4th and 2nd Order Polynomial Regression Model respectively. The prediction value of 1995 by estimated polynomial regression model anticipated that body height of 3rd grade year students of high school of males in 1993 went on increasing from 170.87cm to 171.79cm in average 0.92cm growth and that of females from 158.99cm to 160.79cm in average 1.80cm growth. In addition, body weight of males seemed to increase from 62.58kg to 64.52kg in average 1.94kg growth and that of females seemed to increase from 54.05kg to 54.19kg in average 0.14kg growth. Linear Regression Model was suitable for the regression model of body weight for body height. Prediction on increase of an average body weight for body height was that, according to growth of body height 1cm in males, body weight increased 1.41kg averagely and that of females 0.86kg. For that reason, we came to conclusion that body weight increase for body height 1cm in males was greater than that in females on average.

  • PDF

A Physiologically Based Pharmacokinetic Model for Absorption and Distribution of Imatinib in Human Body

  • Chowdhury, Mohammad Mahfuz;Kim, Do-Hyun;Ahn, Jeong-Keun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.11
    • /
    • pp.3967-3972
    • /
    • 2011
  • A whole body physiologically based pharmacokinetic (PBPK) model was applied to investigate absorption, distribution, and physiologic variations on pharmacokinetics of imatinib in human body. Previously published pharmacokinetic data of the drug after intravenous (i.v.) infusion and oral administration were simulated by the PBPK model. Oral dose absorption kinetics were analyzed by adopting a compartmental absorption and transit model in gut section. Tissue/plasma partition coefficients of drug after i.v. infusion were also used for oral administration. Sensitivity analysis of the PBPK model was carried out by taking parameters that were commonly subject to variation in human. Drug concentration in adipose tissue was found to be higher than those in other tissues, suggesting that adipose tissue plays a role as a storage tissue for the drug. Variations of metabolism in liver, body weight, and blood/plasma partition coefficient were found to be important factors affecting the plasma concentration profile of drug in human body.

Comparison and Analysis for Evaluation of Ride and SEAT Index through Theoretical Seat-Human Body Model and Vehicle Test (시트-인체 해석 모델링과 차량 주행 시험을 통한 차량 승차감 평가와 시트 지수의 비교 및 분석)

  • Son, In-Suk;Kim, Jung-Hoon;Kang, Yeon-June
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.17 no.4
    • /
    • pp.1-9
    • /
    • 2009
  • A simplified model of seat-human body is presented to analyze vibrations of human body on a seat of vehicle. The theoretical model having seven degrees-of-freedom is composed of the inter-connected masses, springs and dampers. Until now, evaluation of ride comfort has been usually performed only through vehicle tests. This study aims to complement shortcomings of conventional vehicle tests in evaluation of ride comfort by using the theoretical model. The acceleration values of the human body are obtained from frequency response functions of the theoretical model. Thereafter, Ride and SEAT indexes are acquired by considering response characteristics of the human body for the 12 axes that are presented in BS 6841. A vehicle test is carried out to measure the acceleration values for the three parts of the human body such as upper body, hip and foot. Ride and SEAT indexes of the vehicle test are also obtained by considering the response characteristics of the human body, of which results are compared with the values from the theoretical model. It is found that the theoretical results are in good agreement with the experimental results.

The Simulation of LES Model For Premixed Combustion around A Bluff Body (LES 모델을 적용한 Bluff-body 주위의 예혼합 연소 해석)

  • Jung, Eui-Man;Ku, Ja-Yeo
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.4
    • /
    • pp.41-49
    • /
    • 2009
  • This paper present result of numerical simulation of premixed combustion around a triangle Bluff Body. And a numerical simulation of a premixed flame stabilization by a bluff body was performed using LES Model. The calculated results from the LES showed a good agreement with experiment data than k-model. Premixture combustion has flammability limit, quenching distance, smallest ignition energy has the combustion quality of the back. Bluff body makes a recirculation zone. Therefor velocity of behind bluff body is very slow. It was caused by slowly position speed and the fire occurred after the Bluff Body. Occurrence of fire it made the waste gas of high speed and the thrust made well.

  • PDF

Development of $5^{th}$ percentile female finite Element Model for Crashworthiness Simulation - Part I Articulated Rigid Body Model (충돌 안전도 해석을 위한 $5^{th}$ percentile 성인 여성 유한요소 모델 개발 - Part I 다물체 동력학 모델 개발)

  • 나상진;최형연;이진희
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.277-282
    • /
    • 2004
  • In order to investigate the small female occupant behavior and accompanying injury mechanisms in vehicular trash event, a finite element model of $5^{th}$ percentile female has been developed. The model consists of articulated rigid body, which represents the morphology of small female body, and internal components with anatomical details. Articulated rigid body model serves as a basic platform for joining the detail internal skeletons and organs, while itself can be used for representing the overall kinematics of small female occupant. The modeling details such as anthropometry and finite element structure as well as validation results for the articulated rigid body model are introduced in this paper. The second part of the modeling, i.e. the internal components with anatomical details of small female are presented in subsequent part II of the paper.