• Title/Summary/Keyword: model factor

Search Result 11,931, Processing Time 0.045 seconds

Evaluating the reliability of using the deflection amplification factor to estimate design displacements with accidental torsion effects

  • Lin, Jui-Liang;Wang, Wei-Chun;Tsai, Keh-Chyuan
    • Earthquakes and Structures
    • /
    • v.8 no.2
    • /
    • pp.443-462
    • /
    • 2015
  • Some model building codes stipulate that the design displacement of a building can be computed using the elastic static analysis results multiplied by the deflection amplification factor, $C_d$. This approach for estimating the design displacement is essential and appealing in structural engineering practice when nonlinear response history analysis (NRHA) is not required. Furthermore, building codes stipulate the consideration of accidental torsion effects using accidental eccentricity, whether the buildings are symmetric-plan, or asymmetric-plan. In some model building codes, the accidental eccentricity is further amplified by the torsional amplification factor $A_x$ in order to minimize the discrepancy between statically and dynamically estimated responses. Therefore, this warrants exploration of the reliability of statically estimated design displacements in accordance with the building code requirements. This study uses the discrepancy curves as a way of assessing the reliability of the design displacement estimates resulting from the factors $C_d$ and $A_x$. The discrepancy curves show the exceedance probabilities of the differences between the statically estimated design displacements and NRHA results. The discrepancy curves of 3-story, 9-story, and 20-story example buildings are investigated in this study. The example buildings are steel special moment frames with frequency ratios equal to 0.7, 1.0, 1.3, and 1.6, as well as existing eccentricity ratios ranging from 0% to 30%.

Probabilistic Estimation of Thermal Fatigue Performance of Three-Way Catalyst Substrate (삼원 촉매 담체의 확률론적 열피로 성능 평가)

  • Cho, Seok-Swoo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.6
    • /
    • pp.669-676
    • /
    • 2014
  • A three-way catalyst substrate for domestic passenger car satisfies the design criteria for exhaust gas exchange and pressure drop but does not have satisfactory thermal fatigue performance. Prefracture faults in this three-way catalyst substrate has often been discovered in vehicle repair or vehicle inspection facilities. This paper presents a thermal fatigue performance estimation method for a three-way catalyst substrate using a probabilistic strength reduction factor model. This method is superior to the thermal fatigue performance estimation method for a three-way catalyst substrate that uses a deterministic strength model.

Dynamic load concentration caused by a break in a Lamina with viscoelastic matrix

  • Reza, Arash;Sedighi, Hamid M.;Soleimani, Mahdi
    • Steel and Composite Structures
    • /
    • v.18 no.6
    • /
    • pp.1465-1478
    • /
    • 2015
  • The effect of cutting off fibers on transient load in a polymeric matrix composite lamina was studied in this paper. The behavior of fibers was considered to be linear elastic and the matrix behavior was considered to be linear viscoelastic. To model the viscoelastic behavior of matrix, a three parameter solid model was employed. To conduct this research, finite difference method was used. The governing equations were obtained using Shear-lag theory and were solved using boundary and initial conditions before and after the development of break. Using finite difference method, the governing integro-differential equations were developed and normal stress in the fibers is obtained. Particular attention is paid the dynamic overshoot resulting when the fibers are suddenly broken. Results show that considering viscoelastic properties of matrix causes a decrease in dynamic load concentration factor and an increase in static load concentration factor. Also with increases the number of broken fibers, trend of increasing load concentration factor decreases gradually. Furthermore, the overshoot of load in fibers adjacent to the break in a polymeric matrix with high transient time is lower than a matrix with lower transient time, but the load concentration factor in the matrix with high transient time is lower.

Acoustic Noise Reduction and Power Factor Correction in Switched Reluctance Motor Drives

  • Rashidi, Amir;Saghaiannejad, Sayed Mortaza;Mousavi, Sayed Javad
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.37-44
    • /
    • 2011
  • In this paper, a four-phase 8/6-pole 4-kW SR motor drive model is presented. Based on experimental data, the model allows an accurate simulation of a drive in dynamic operation. Simulations are performed and a laboratory type set-up is built based on a TI TMS320F2812 platform to experimentally verify the theoretical results obtained for a SR motor. To reduce acoustic noise and to correct the power factor of this drive, a two-stage power converter is proposed that uses a current source rectifier (CSR) as the input stage for the asymmetrical converter of the studied SRM. Employing the space-vector modulation (SVM) method in matrix converters, the CSR switching allows the dc link's capacitors to be eliminated and the power factor of the SRM drive to be improved. As the electrical motive force (emf) is directly proportional to the rotor speed, the input voltage to the machine can be programmed to be a function of the speed with the modulation index of the CSR, leading to a reduction in the acoustic noise of the SRM drive. Simulation of the whole SRM drive system is performed using MATLAB-Simulink. The results fully comply with the required conditions such as power factor correction with an improvement in the THD.

Uncertainty Evaluation of Velocity Integration Method for 5-Chord Ultrasonic Flow Meter Using Weighting Factor Method (가중계수법을 이용한 5회선 초음파 유량계의 유속적분방법의 불확도 평가)

  • Lee, Ho-June;Lee, Kwon-Hee;Noh, Seok-Hong;Hwang, Sang-Yoon;Noh, Young-Ah
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.287-294
    • /
    • 2005
  • Flow rate measurement uncertainties of the ultrasonic flow meter are generally influenced by many different factors, such as Reynolds number, flow distortion, turbulence intensity, wall surface roughness, velocity integration method along the acoustic paths, and transducer installation method, etc. Of these influencing factors, one of the most important uncertainties comes from the velocity integration method. In the present study, a optimization weighting factor method for 5-chord, which is given by a function of the chord locations of acoustic paths, is employed to obtain the mean velocity in the flow through a pipe. The power law profile is assumed to model the axi-symmetric pipe flow and its results are compared with the present weighting factor concept. For an asymmetric pipe flow, the Salami flow model is applied to obtain the velocity profiles. These theoretical methods are also compared with the previous Gaussian, Chebyshev, and Tailor methods. The results obtained show that for the fully developed turbulent pipe flows with surface roughness effects, the present weighting factor method is much less sensitive than Chebyshev and Tailor methods, leading to a better reliability in flow rate measurement using the ultrasonic flow meters.

  • PDF

Application of the Daylight Factor Formula with the Modified Split Flux (Modified Split Flux를 이용한 주광률 계산식 적용에 관한 연구)

  • Yun, Su-In;Yun, Gyeong;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.39-47
    • /
    • 2014
  • Daylighting has a great effect on people inside the room. It is also closely related to the lighting energy consumption. Daylight factor(DF) is a very important index for evaluation of the daylighting in overcast sky. The objective of this study is to verify the suitability of the Tregenza's Modified Split Flux formula for the calculation of the daylight factor. We compared the daylight factors calculated by two methods; one by a measurement with 1/5 scale model and the other by the Daysim program. We used variables for verification as window wall ratios(WWR) and angles of the sky visible. As a result, daylight factor calculated by Modified Split Flux is similar to the measurement when more daylight enters the inside. And error is significantly increased when the angle of the sky visible is $50^{\circ}$.

Dynamic increase factor for progressive collapse analysis of semi-rigid steel frames

  • Zhu, Yan Fei;Chen, Chang Hong;Yao, Yao;Keer, Leon M.;Huang, Ying
    • Steel and Composite Structures
    • /
    • v.28 no.2
    • /
    • pp.209-221
    • /
    • 2018
  • An empirical and efficient method is presented for calculating the dynamic increase factor to amplify the applied loads on the affected bays of a steel frame structure with semi-rigid connections. The nonlinear static alternate path analysis is used to evaluate the dynamic responses. First, the polynomial models of the extended end plate and the top and seat connection are modified, and the proposed polynomial model of the flush end plate connection shows good agreement as compared with experimental results. Next, a beam model with nonlinear spring elements and plastic hinges is utilized to incorporate the combined effect of connection flexibility and material nonlinearity. A new step-by-step analysis procedure is established to obtain quickly the dynamic increase factor based on a combination of the pushdown analysis and nonlinear dynamic analysis. Finally, the modified dynamic increase factor equation, defined as a function of the maximum ratio value of energy demand to energy capacity of an affected beam, is derived by curve fitting data points generated by the different analysis cases with different column removal scenarios and five types of semi-rigid connections.

Design of Active Power Factor Corrector for Low Power Supply by Loss Free Resistor Concept (무손실 저항개념을 이용한 저전력 전원설비용 능동 역률보정기의 설계)

  • 임영철;정영국;최찬학;나석환;이건식;장영학
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.7 no.1
    • /
    • pp.30-36
    • /
    • 1993
  • A simple discontinuous conduction mode(DCM) flyback type active power factor corrector for low power supply resents an effective resistive load to its power input. It is therefore well suited as an inexpensive high power factor rectifier for office equipment. An equivalent circuit model for the Active Power Factor Corrector based on the "Loss Free Resistor" concept is presented. This simple model correctly describes the basic power processing properties of the Active Power Factor Corrector, including input port resistor emulation, output port power some characteristics.teristics.

  • PDF

Development of a Scale for Measuring Nurses' Stress (간호사의 스트레스 측정도구 개발)

  • Kang, Younhee;Lee, Kyungmi;Hur, Yujin
    • Journal of Korean Clinical Nursing Research
    • /
    • v.30 no.1
    • /
    • pp.11-23
    • /
    • 2024
  • Purpose: This study developed a scale of nurses' stress and examined the validity and reliability of the scale. Methods: The scale was developed according to DeVellis' scale development procedure. Based on the Nursing Work Environment Stress model and the results of focus group interviews, 43 preliminary items were generated. A survey was conducted with 208 clinical nurses to test the psychometric properties of the scale. Both exploratory factor analysis and confirmatory factor analysis were employed to figure out and confirm the scale's theoretical structure statistically. In addition, content, convergent, and discriminative validity were evaluated and Cronbach's α was calculated to test internal reliability. Results: The final scale consisted of 19 items and verified four-factor structures. The structure of the scale was confirmed using confirmatory factor analysis, and it showed moderate correlations with the Copenhagen Burnout Inventory and Korean Nurses Occupational Stress Scale. Cronbach's α was .87. Conclusion: A scale of nurses' stress to nursing work was developed to embrace a wide range of nurses' psychological responses to nursing work based on the theoretical model.

A Study of Influencing Factors Upon Using C4I Systems: The Perspective of Mediating Variables in a Structured Model (C4I 시스템 사용의 영향 요인에 관한 연구: 구조모형의 매개변수의 관점에서)

  • Kim, Chong-Man;Kim, In-Jai
    • Asia pacific journal of information systems
    • /
    • v.19 no.2
    • /
    • pp.73-94
    • /
    • 2009
  • The general aspects for the future warfare shows that the concept of firepower and maneuver centric warfare has been replacing with that of information and knowledge centric warfare. Thus, some developed countries are now trying to establish the information systems to perform intelligent warfare and innovate defense operations. The C4I(Command, Control, Communication, Computers and Intelligence for the Warrior) systems make it possible to do modern and systematic war operations. The basic idea of this study is to investigate how TAM(Technology Acceptance Model) can explain the acceptance behavior in military organizations. Because TAM is inadequate in explaining the acceptance processes forcomplex technologies and strict organizations, a revised research model based upon TAM was developed in order to assess the usage of the C4I system. The purpose of this study is to investigate factors affecting the usage of C4I in the Korean Army. The research model, based upon TAM, was extended through a belief construct such as self-efficacy as one of mediating variables. The self-efficacy has been used as a mediating variable for technology acceptance, and the variable was included in the research model. The external variables were selected on the basis of previous research. The external variables can be classified into following: 1) technological, 2) organizational, and 3) environmental factors on the basis of TOE(Technology-Organization-Environment) framework. The technological factor includes the information quality and the task-technology fitness. The organizational factor includes the influence of senior colleagues. The environmental factor includes the education/train data. The external variables are considered very important for explaining the behavior patterns of information technology or systems. A structured questionnaire was developed and administrated to those who were using the C4I system. Total 329 data were used for statistical data analyses. A confirmatory factor analysis and structured equation model were used as main statistical methods. Model fitness Indexes for measurement and structured models were verified before all 18 hypotheses were tested. This study shows that the perceived usefulness and the self-efficacy played their roles more than the perceived ease of use did in TAM. In military organizations, the perceived usefulness showed its mediating effects between external variables and dependent variable, but the perceived ease of use did not. These results imply that the perceived usefulness can explain the acceptance processes better than the perceived ease of use in the army. The self-efficacy was also used as one of the three mediating variables, and showed its mediating effects in explaining the acceptance processes. Such results also show that the self-efficacy can be selected as one possible belief construct in TAM. The perceived usefulness was influenced by such factors as senior colleagues, the information quality, and the task-technology fitness. The self-efficacy was affected by education/train and task-technology fitness. The actual usage of C4I was influenced not by the perceived ease of use but by the perceived usefulness and selfefficacy. This study suggests the followings: (1) An extended TAM can be applied to such strict organizations as the army; (2) Three mediation variables are included in the research model and tested at real situations; and (3) Several other implications are discussed.