• Title/Summary/Keyword: model factor

Search Result 11,932, Processing Time 0.036 seconds

Capillary Hysteresis Model in Unsaturated Flow - Development of Model - (비포화 흐름에서 모세관 이력현상 모형의 고찰 - 모형의 개발 -)

  • Park, Chang Kun;Sonu, Jung Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.4
    • /
    • pp.131-140
    • /
    • 1993
  • A new model which requires one branch of main curves for the model calibration is developed based on the assumption that the weighting factor accounting for the pore blockage effect against air entry, $P_a({\theta})$, in Mualem's Model III-1 has a linear relation to the dimensionless pore radius r. The proposed model simulates experimental data more accurately than existing models which require one branch of main curves for the model calibration. Previous study showed that Model III-1 is the most appropriate model among domain models which require two branches of main curves for the model calibration. In comparison of the proposed model with Model III-1, both simulate hysteresis curves with almost the same accuracy. The proposed model can be applied efficiently in analyzing the unsaturated flow.

  • PDF

Development of a hybrid regionalization model for estimation of hydrological model parameters for ungauged watersheds (미계측유역의 수문모형 매개변수 추정을 위한 하이브리드 지역화모형의 개발)

  • Kim, Youngil;Seo, Seung Beom;Kim, Young-Oh
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.8
    • /
    • pp.677-686
    • /
    • 2018
  • There remain numerous ungauged watersheds in Korea owing to limited spatial and temporal streamflow data with which to estimate hydrological model parameters. To deal with this problem, various regionalization approaches have been proposed over the last several decades. However, the results of the regionalization models differ according to climatic conditions and regional physical characteristics, and the results of the regionalization models in previous studies are generally inconclusive. Thus, to improve the performance of the regionalization methods, this study attaches hydrological model parameters obtained using a spatial proximity model to the explanatory variables of a regional regression model and defines it as a hybrid regionalization model (hybrid model). The performance results of the hybrid model are compared with those of existing methods for 37 test watersheds in South Korea. The GR4J model parameters in the gauged watersheds are estimated using a shuffled complex evolution algorithm. The variation inflation factor is used to consider the multicollinearity of watershed characteristics, and then stepwise regression is performed to select the optimum explanatory variables for the regression model. Analysis of the results reveals that the highest modeling accuracy is achieved using the hybrid model on RMSE overall the test watersheds. Consequently, it can be concluded that the hybrid model can be used as an alternative approach for modeling ungauged watersheds.

Development and Validation of the Empowerment Scale for Woman with Breast Cancer (유방암여성 임파워먼트 측정도구 개발 및 타당화)

  • Shin, Sun Hwa;Park, Hyojung
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.4
    • /
    • pp.613-624
    • /
    • 2015
  • Purpose: The purpose of this study was to develop a scale to evaluate empowerment in woman with breast cancer and to examine the validity and reliability of the scale. Methods: The development process for the initial items included a literature review, interviews, and construction of a conceptual framework. The identified items were evaluated for content validity by experts, resulting in 3 factors and 48 preliminary items. Participants were 319 women with breast cancer recruited to test reliability and validity of the preliminary scale. Data were analyzed using item analysis, confirmatory factor analysis, criterion related validity, internal consistency and test-retest reliability. Results: The final scale consisted of 30 items and 3 factors. Factors, including 'intrapersonal factor' (14 items), 'interactional factor' (8 items), and 'behavioral factor' (8 items), were drawn up after confirmatory factor analysis. Goodness of fit of the final research model was very appropriate as shown by ${\chi}^2/df=1.86$, TLI=.90, CFI=.92, SRMR=.06, and RMSEA=.05. Criterion validity was evaluated by total correlation with the Cancer Empowerment Questionnaire .78. Cronbach's alpha for total items was .93 and test-retest reliability was .69. Conclusion: Findings from this study indicate that the scale can be used in the development of nursing interventions to promote the empowerment of women having breast cancer.

Cross-cultural Validation of Instruments Measuring Health Beliefs about Colorectal Cancer Screening among Korean Americans

  • Lee, Shin-Young;Lee, Eunice E.
    • Journal of Korean Academy of Nursing
    • /
    • v.45 no.1
    • /
    • pp.129-138
    • /
    • 2015
  • Purpose: The purpose of this study was to report the instrument modification and validation processes to make existing health belief model scales culturally appropriate for Korean Americans (KAs) regarding colorectal cancer (CRC) screening utilization. Methods: Instrument translation, individual interviews using cognitive interviewing, and expert reviews were conducted during the instrument modification phase, and a pilot test and a cross-sectional survey were conducted during the instrument validation phase. Data analyses of the cross-sectional survey included internal consistency and construct validity using exploratory and confirmatory factor analysis. Results: The main issues identified during the instrument modification phase were (a) cultural and linguistic translation issues and (b) newly developed items reflecting Korean cultural barriers. Cross-sectional survey analyses during the instrument validation phase revealed that all scales demonstrate good internal consistency reliability (Cronbach's alpha=.72~.88). Exploratory factor analysis showed that susceptibility and severity loaded on the same factor, which may indicate a threat variable. Items with low factor loadings in the confirmatory factor analysis may relate to (a) lack of knowledge about fecal occult blood testing and (b) multiple dimensions of the subscales. Conclusion: Methodological, sequential processes of instrument modification and validation, including translation, individual interviews, expert reviews, pilot testing and a cross-sectional survey, were provided in this study. The findings indicate that existing instruments need to be examined for CRC screening research involving KAs.

Performance Test of A Reverse-Annular Type Combustor (TS2) for APU (보조동력장치용 환형 역류형 연소기 (TS2) 성능 시험)

  • Ko, Young-Sung;Han, Yeoung-Min;Yang, Soo-Seok;Lee, Dae-Sung;Yun, Sang-Sig;Choi, Sung-Man
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.840-845
    • /
    • 2001
  • Development of a small gas-turbine combustor for 100kW class APU(Auxiliary Power Unit) has been performed. This combustor is a reverse-annular type and has a tangential swirler in the liner head to improve the fuel/air mixing and flame stability. Three main and three pilot fuel injectors of the simplex pressure-swirl type are used. The performance target at the design condition includes a turbine inlet temperature of 1170K, a combustion efficiency of 99%, a pattern factor of 30%, and an engine durability of 3000 hours. Under developing the combustor, we conducted performance test of our first prototype(TS1) with some variants. As a result of the test, the performance targets of the combustor are satisfied except that the pattern factor is about 4% higher than target value. So, we redesigned the second prototype(TS2) and conduct performance test with the critical focus on pattern factor and exit mean temperature. We adopted TS2 four variant to check the improvement of pattern factor. As the result, the pattern factors of several variants were satisfied with the performance target. Finally, We chose the TS2A variant as a final combustor for our APU model.

  • PDF

Development of a Teacher-Efficacy Scale for Health Education Teachers (보건교사의 교사효능감 척도 개발)

  • Yi, Chung-Ran;Kwon, Nak-Won
    • Research in Community and Public Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.247-259
    • /
    • 2008
  • Purpose: This study was conducted to develop a teacher-efficacy scale which is adequate for heath education teachers. Method: A preliminary questionnaire was made based on the hypothetical factors. A total of 364 health education teachers answered to the preliminary test, and the potential factors of teacher-efficacy were checked out by exploratory factor analysis (EFA). In the main test 378 health education teachers answered, the factor structure was drawn by EFA, and confirmatory factor analysis (CFA) was conducted to test and the fitness of the factor model. Results: Through the preliminary test, 5 potential factors were found, which were instruction, health-service, administrative task, interpersonal relationship, and community connection. Also, 48 items were reduced to 31 items. Through the main test, from the 34 items were extracted 4 factors with 24 items, And then teacher-efficacy scale was developed, which included the subscales of instruction efficacy, health-service efficacy, task-interpersonal efficacy, and community connection efficacy. Conclusion: Different from that for other subject teachers, the factor structure for health teachers had 4 factors with 24 items. The scale developed in this study is consistent with health teachers' work areas, and for this reason, has significance as a adequate and valid scale to measure teacher-efficacy of health education teachers.

  • PDF

Robust and Unity Input Power Factor Control Scheme for Electric Vehicle Battery Charger (전기차 배터리 충전기용 강인한 단위 입력 역률 제어장치)

  • Nguyen, Cong-Long;Lee, Hong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.20 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • This study develops a digital control scheme with power factor correction for a front-end converter in an electric vehicle battery charger. The front-end converter acts as the boost-type switching-mode rectifier. The converter assumes the two roles of the battery charger, which include power factor control and robust charging performance. The proposed control scheme consists of a charging control algorithm and a grid current control algorithm. The scheme aims to obtain unity input power factor and robust performance. Based on the linear average model of the converter, a constant-current constant-voltage charging control algorithm that passes through only one proportional-integral controller and a current feed-forward path is proposed. In the current control algorithm, we utilized a second band pass filter, a single-phase phase-locked loop technique, and a duty-ratio feed-forward term to control the grid current to be in phase with the grid voltage and achieve pure sinusoidal waveform. Simulations and experiments were conducted to verify the effectiveness of the proposed control scheme, both simulations and experiments.

A Photoelastic Study on Change of Stress Concentration Factor Due to Unsymmetrical Change of Notch Angle (Pure Bending Moment 하(下)에 있는 Notched Strip에서의 Notch Angle의 비대칭적(非對稱的) 변화(變化)에 의(依)한 응력집중계수(應力集中係數)의 변화(變化))

  • Jang-Chule,Mun
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.4 no.1
    • /
    • pp.55-58
    • /
    • 1967
  • It is investigated that in what shape the stress concentration factor of a notched strip under pure bending changes due to unsymmetrically varying notch angle. Four models made of CR-39, having parameters of r/d-0.225, h/r=4; r/d=0.225, h/r=2; r/d=0.4, h/r=4 and r/d=0.4, h/r=2 respectively as shown in Fig.1, Fig.2 and Table are tested with the use of polariscope. For each model, notch angle is unsymmetrically varied from $0^{\circ}$ to $180^{\circ}$ at intervals of $15^{\circ}$ as shown in Fig. 1 and Fig. 2. The results of this experiment are Fig. 7 and Fig. 8 and the following are deduced. As notch angle increases 1) from $0^{\circ}$ to $50^{\circ}$, the decrement of concentration factor is slight. 2) from $50^{\circ}$ to 90, the decrement of concentration factor is a little steeper. 3) from $30^{\circ}$ to $140^{\circ}$, the decrement of concentration factor is slight. 4) from $140^{\circ}$ to $180^{\circ}$, the decrement is very steep with an abrupt with an abrupt change in the neighborhood of $140^{\circ}$.

  • PDF

A Study of Factors Affecting on Trust and Participation of Group Buying on the Internet (인터넷 공동구매 신뢰와 참여에 영향을 미치는 요인에 관한 연구)

  • 고일상;장정주;이영훈
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2002.11a
    • /
    • pp.125-135
    • /
    • 2002
  • With rapid growth and competition of electronic commerce through internet, various buying types and business models are being appeared In this paper, we studied group buying which is new business model to consumer and factors affecting on trust and participation of group buying. The following are the regression result of this study. First, factors affecting on trust of group buying were different from factors affecting on participation of group buying. Second, perceived reputation factor, familiarity factor and product value factor made a significant effect on participation of group buying. Third customer service factor didn't make a significant effect on both participation and trust of group buying. Fourth, product value factor made a significant effect on both participation and trust of group buying. Fifth trust of group buying made a significant effect on participation of group buying

  • PDF

Revisiting Prediction Tools for Daylight Adequacy and Its Potential Improvement

  • Kim, Dong Hyun
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.35-44
    • /
    • 2017
  • Purpose: This study questioned the efficiency of daylight factor as a daylight adequacy and investigated a method of how to complement its weakness by considering a direct sunlight component under a clear sky condition. Method: The Snowdon visitor centre cafe was chosen as a case study building and various techniques such as BRE formula, BRE sky protractor, Pilkington dot diagram and mock-upscale model under the artificial sky simulator were used to analyse and compare daylight factor values. An analysis of direct sunlight component under the clear sky condition was carried out by Climate Consultant 5.5, sun path diagram, and the artificial sky simulator. Result: The result of daylight factor analysis differed by the adopted techniques and it was also contradictory to the results on a direct sunlight penetration. The result not only showed the limitation of daylight factor as a metric but also suggested an improvement by combining it with direct sunlight analysis. The techniques used in this study had a merit of being applied in the early design stage and thus be beneficial to many design professions in order for early daylight performance analysis.