• Title/Summary/Keyword: model B3

Search Result 3,811, Processing Time 0.036 seconds

A Prediction Model of Droplet Size of Rotary Spray Dryer at Various Operating Conditions (원심식(遠心式) 분무건조장치(噴霧乾燥裝置)의 작동조건(作動條件)에 따른 분무입자(噴霧粒子)의 입도예측(粒度豫測) 모델)

  • Noh, S.H.;Kim, K.B.;Lee, J.W.;Lee, S.J.
    • Journal of Biosystems Engineering
    • /
    • v.17 no.3
    • /
    • pp.229-236
    • /
    • 1992
  • In an effort to localize the spray-dryer which is markedly used for drying food materials, a experiment was carried out with a wheel type atomizer locally designed and manufactured to evaluate the effect of rotational speed, feed rate and physical properties of liquid food material on the droplet size, and to develop a model to predict the droplet size sprayed at various operational conditions. The result are summarized as follows. 1. The frequency of droplet size sprayed from the atomizer at every treatment were similar to normal distributions. 2. Under the test conditions adopted in this study, that is, rotational speed of the atomizer ranging from 15,000 to 20,000 rpm (55.0 m/sec - 73.3 m/sec), feed rate from 14 to 37 kg/hr and viscosity of the material from 1.14 to 350 cP, the mean volume-surface dia. of droplets was decreased as increase in rotational speed and was not affected significantly by the feed rate and viscosity. 3. Through the dimensional analysis, a prediction model was developed as follows : $$\frac{Dvs}{r}=K[\frac{Q}{{\mu}r}]^a[\frac{rN^2}{g}]^b[\frac{{\rho}^2r^3g}{{\mu}^2}]^c[\frac{L}{r}]^d$$ and it was proved that the above model was better in degree of fitness than other models reported. 4. A prediction equation for the droplet size sprayed from the atomizer under the test was expressed as follows : $$\frac{Dvs}{r}=0.0215[\frac{Q}{{\mu}r}]^{0.06}[\frac{rN^2}{g}]^{0.3314}[\frac{{\mu}^2}{{\rho}^2r^3g}]^{0.0158}$$.

  • PDF

A Study on the Risk Assessment and Reduction of Initial Construction Cost in a Biosafety Laboratory According to Improvement of Supply and Exhaust Method (급배기 방식 개선에 따른 생물안전 밀폐시설의 Risk Assessment와 초기 건설비 저감에 대한 연구)

  • Hwang, Ji Hyun;Hong, Jin Kwan;Ju, Young Duk
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.10
    • /
    • pp.534-539
    • /
    • 2013
  • In general, entire supply air of the BSL3 laboratory should be vented to the outside for its biosafety and the air conditioning system should always be operating to maintain a room pressure difference. In this regard, annual energy consumption is approximately five or ten times greater than the magnitude of the office building. In addition, to adjust room pressure difference to the set value efficiently, the supply and exhaust duct system are installed in each room of the BSL3 lab. Thus, initial construction cost is extremely high. In this study, multizone simulation is performed to estimate maintaining the appropriate room pressure difference in the case of changing model A (each room supply and exhaust system) to model B (each zone supply and exhaust system) for verification of the BSL3 lab biosafety. Also, in the case of these two models, the multizone simulation for three kinds of biohazard scenario is performed as part of risk assessment. The analysis of initial construction cost of two models is conducted for comparison. According to the studies, initial construction cost of model B is less than about 22% of existing model A. Moreover, biosafety of the BSL3 lab is still maintaining in the case of the two models.

Comparative Analysis of 3 Experimental Mouse Model for Blood Hematology and Chemistry

  • Kong, Dae Young;Park, Jung Hwan;Lee, Kyo Won;Park, Ho;Cho, Jung Ah
    • Biomedical Science Letters
    • /
    • v.22 no.3
    • /
    • pp.75-82
    • /
    • 2016
  • The immune system and neuroendocrine systems are the two key components that maintain bodily homeostasis. Peripheral blood specimens can indicate abnormalities in a body, which often cause various threats to human health, including devastating autoimmune or metabolic diseases. To develop a treatment regimen for such diseases, experimental animal models are indispensable to researchers in academic fields. In this study, we examined the peripheral blood of 3 representative mouse strains (ICR, Balb/c, and C57Bl/6), which are widely used, to investigate whether there is a difference in reference range according to animal model. We performed hematological and chemistry analysis on individuals of both genders. The results of hematology analysis showed that the number of most types of blood cells was lower in ICR than in the other two strains. The results of chemical analysis revealed no specific pattern, but different patterns according to the individual indicator. Although the distinction between ICR and B6 was prominent, differences between Balb/c and B6 were also observed for several indicators. For some indicators, totally different patterns existed between females and males. Conclusively, this study provides the information that 3 experimentally representative mouse models have their own basal levels of blood components, suggesting the importance of a careful choice of a proper mouse model in research into immune or metabolic diseases, to exclude any biases.

Analysis of Elbow Reflexes Using Activation Model for Stretch Reflex (신장반사로 인한 근활성도 예측 모델을 이용한 삼두박근 반사 해석)

  • Kang, Moon Jeong;Jo, Young Nam;Chae, Je Wook;Yoo, Hong Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.3
    • /
    • pp.215-221
    • /
    • 2015
  • The elbow reflex, a principal reflex in the upper extremity, plays an important role in the diagnosis of cervical spine syndromes. In this study, the muscle activations of brachial biceps and triceps, and the kinematics of upper extremities were predicted using an activation model for the stretch reflex. The muscle activations that equated the simulation results estimated by the analysis model with the experimental results were obtained first, and the activations obtained from the simulations were compared with the electromyography signals obtained from the experiments, for model validation. The root mean squares error of the joint angles (obtained from experiments and simulation using the suggested model) was 0.056, a value that is half of that obtained using the previous model. This demonstrates that the suggested model corresponded well with the actual reflex.

A New k-$\varepsilon$ Model for Prediction of Transitional Boundary-Layer Under Zero-Pressure Gradient (압력 구배가 없는 평판 천이 경계층 유동을 예측하기 위한 k-$\varepsilon$모형의 개발)

  • Baek, Seong-Gu;Im, Hyo-Jae;Jeong, Myeong-Gyun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.3
    • /
    • pp.305-314
    • /
    • 2001
  • A modified model is proposed for calculation of transitional boundary layer flows. In order to develop the eddy viscosity model for the problem, the flow is divided into three regions; namely, pre-transition region, transition region and fully turbulent region. The pre-transition eddy-viscosity is formulated by extending the mixing length concept. In the transition region, the eddy-viscosity model employs two length scales, i.e., pre-transition length scale and turbulent length scale pertaining to the regions upstream and the downstream, respectively, and a universal model of stream-wise intermittency variation is used as a function bridging the pre-transition region and the fully turbulent region. The proposed model is applied to calculate three benchmark cases of the transitional boundary layer flows with different free-stream turbulent intensity (1%∼6%) under zero-pressure gradient. It was found that the profiles of mean velocity and turbulent intensity, local maximum of velocity fluctuations, their locations as well as the stream-wise variation of integral properties such as skin friction, shape factor and maximum velocity fluctuations are very satisfactorily predicted throughout the flow regions.

Anti-dermatitis Effects of KamiCheongsimyeonjatang on GATA-3 Regulation in NC/Nga Mouse (NC/Nga 생쥐에서 가미청심연자탕(加味淸心蓮子湯)의 GATA-3 조절에 의한 항아토피 피부염 효과)

  • Park, Seul-Ki;Han, Jae-Kyung;Kim, Yun-Hee
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.29-50
    • /
    • 2009
  • Objectives : The purpose of this study is to investigate effectiveness of KamiCheongsimyeonjatang(KCSYJT) medicines to suppress atopic dermatitis in mouse model experimentally. Methods : First, in vitro, we isolated B cells from 18 weeks of atopicdermatitis-like skin NC/Nga mouse. Then we analyzed FACS(Fluorescence Activated Cell Sorter) by intracellular staining of IFN-$\gamma$, GATA-3+ analyzed cytokines by using real-time PCR. Secondly, in vivo, after administration of KCSYJT to atopic dermatitis NC/Nga mouse at 12 weeks of age, we analyzed serum IgE and the change of activated cell in PBMCs(Peripheral Blood Mononuclear Cells). Results : In vitro, KCSYJT medicines supressed IL-1$\beta$, IL-6, TNF-$\alpha$, and TGF-$\beta$ mRNA and increased IL-10 mRNA in B cells. Also, KCSYJT medicines decreased the levels of GATA-3$^+$CD4$^+$ and increased the levels of IFN-$\gamma^+$CD4$^+$T Cell. In vivo, serum IgE levels dreased in KCSYJT group than control group and In PBMCs, the activated cell percentage of granulocytes, CD3+, CD3+/CD4+, B220+/CD23+, and CCR3+ decreased and CD19+, CD3+/CD8+ increased in KCSYJT group than control group. Conclusions : This study demonstrates immunological activity of KCSYJT on atopic dermatitis-like model mice.

  • PDF

Convergence Study on Durability Analysis of Scooter Seat (스쿠터 시트의 내구성 해석에 관한 융합 연구)

  • Oh, Bum-Suk;Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.6
    • /
    • pp.165-170
    • /
    • 2019
  • This study carried out the structural analysis and vibration analysis on scooter seat. By comparing with three kinds of B-bone A, Julio B, and City Ace C, the load was applied to scooter seat as much as a weight of person. Through structural analysis, this study examined which seat is most deformed by comparing the deformation each other or affords passengers most convenience and does not afford passengers the inconvenience by absorbing the vibration during driving. Model C has the most total deformation at the structural analysis result and Model B is seen to be changed to be convenient to sit the deformation as it deforms largely. Through this study, which seat is most convenient and becomes strong on durability can be confirmed. As the durability analysis result data of scooter seat model obtained on the basis of this study result are utilized, the esthetic sense can be shown by being grafted onto the machine or structure at real life.

The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study

  • Roberto Giffi;Davide Pietropaoli;Leonardo Mancini;Francesco Tarallo;Philipp Sahrmann;Enrico Marchetti
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.4
    • /
    • pp.295-305
    • /
    • 2023
  • Purpose: Various methods have been proposed to achieve the nearly complete decontamination of the surface of implants affected by peri-implantitis. We investigated the in vitro debridement efficiency of multiple decontamination methods (Gracey curettes [GC], glycine air-polishing [G-Air], erythritol air-polishing [E-Air] and titanium brushes [TiB]) using a novel spectrophotometric ink-model in 3 different bone defect settings (30°, 60°, and 90°). Methods: Forty-five dental implants were stained with indelible ink and mounted in resin models, which simulated standardised peri-implantitis defects with different bone defect angulations (30°, 60°, and 90°). After each run of instrumentation, the implants were removed from the resin model, and the ink was dissolved in ethanol (97%). A spectrophotometric analysis was performed to detect colour remnants in order to measure the cumulative uncleaned surface area of the implants. Scanning electron microscopy images were taken to assess micromorphological surface changes. Results: Generally, the 60° bone defects were the easiest to debride, and the 30° defects were the most difficult (ink absorption peak: 0.26±0.04 for 60° defects; 0.32±0.06 for 30° defects; 0.27±0.04 for 90° defects). The most effective debridement method was TiB, independently of the bone defect type (TiB vs. GC: P<0.0001; TiB vs. G-Air: P=0.0017; TiB vs. GE-Air: P=0.0007). GE-Air appeared to be the least efficient method for biofilm debridement. Conclusions: T-brushes seem to be a promising decontamination method compared to the other techniques, whereas G-Air was less aggressive on the implant surface. The use of a spectrophotometric model was shown to be a novel but promising assessment method for in vitro ink studies.

Transfer Function Model Forecasting of Sea Surface Temperature at Yeosu in Korean Coastal Waters (전이함수모형에 의한 여수연안 표면수온 예측)

  • Seong, Ki-Tack;Choi, Yang-Ho;Koo, Jun-Ho;Lee, Mi-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.526-534
    • /
    • 2014
  • In this study, single-input transfer function model is applied to forecast monthly mean sea surface temperature(SST) in 2010 at Yeosu in Korean coastal waters. As input series, monthly mean air temperature series for ten years(2000-2009) at Yeosu in Korea is used, and Monthly mean SST at Yeosu station in Korean coastal waters is used as output series(the same period of input). To build transfer function model, first, input time series is prewhitened, and then cross-correlation functions between prewhitened input and output series are determined. The cross-correlation functions have just two significant values at time lag at 0 and 1. The lag between input and output series, the order of denominator and the order of numerator of transfer function, (b, r, s) are identified as (0, 1, 0). The selected transfer function model shows that there does not exist the lag between monthly mean air temperature and monthly mean SST, and that transfer function has a first-order autoregressive component for monthly mean SST, and that noise model was identified as $ARIMA(1,0,1)(2,0,0)_{12}$. The forecasted values by the selected transfer function model are generally $0.3-1.3^{\circ}C$ higher than actual SST in 2010 and have 6.4 % mean absolute percentage error(MAPE). The error is 2 % lower than MAPE by ARIMA model. This implies that transfer function model could be more available than ARIMA model in terms of forecasting performance of SST.

Effect of ginger and cinnamon extract mixtures on the growth of intestinal bacteria and intestinal inflammation (생강계피 복합물이 장내 유익균 증식 및 염증조절 기능에 미치는 영향)

  • Kim, Min Ju;Kim, Min Seo;Kang, Sung Tae;Kim, Ji Yeon
    • Journal of Applied Biological Chemistry
    • /
    • v.60 no.4
    • /
    • pp.321-326
    • /
    • 2017
  • We aimed to assess the potential growth-promoting effects of ginger and cinnamon mixtures (GCM) on intestinal bacteria and their anti-inflammatory effects in a cellular model of intestinal inflammation. Bifidobacterium longum, Lactobacillus sp., and Lactobacillus acidophilus served as intestinal bacteria. Further, in the inflammatory co-culture model, Caco-2 cells co-cultured with RAW264.7 cells were treated with GCM before the addition of lipopolysaccharide (LPS) to induce inflammation in RAW264.7 cells. Addition of GCM to modified Eggerth Gagnon media at a ginger:cinnamon ratio of 1:5 increased the growth of B. longum, Lactobacillus sp., and L. acidophilus compared to that of the control. In a cellular model, compared to LPS-treated groups, GCM-treated groups maintained high transepithelial electrical resistance at ginger:cinnamon ratios of 1:1, 1:3, 1:5, and 1:7 and decreased the tight junction permeability at 3:1, 1:1, 1:3, and 1:5 ratios, similar to that shown by the control groups. In addition, GCM-treated groups showed decreased levels of nitrite at 1:1, 1:5, and 1:7 ginger:cinnamon ratios. Based on these results, it can be concluded that among the various combinations of GCM, the ginger:cinnamon ratio of 1:5 is the optimal composite ratio that shows positive effects on the intestinal beneficial bacteria and in anti-inflammation.