• Title/Summary/Keyword: model B3

Search Result 3,811, Processing Time 0.039 seconds

THE EFFECT OF SURFACE TREATMENT OF THE CERVICAL AREA OF IMPLANT ON BONE REGENERATION IN MINI-PIG (미니돼지에서 발치 후 즉시 임플란트 매식시 치경부 표면처리가 골재생에 미치는 효과)

  • Cho, Jin-Yong;Kim, Young-Jun;Yu, Min-Gi;Kook, Min-Suk;Oh, Hee-Kyun;Park, Hong-Ju
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.34 no.3
    • /
    • pp.285-292
    • /
    • 2008
  • Purpose: The present study was performed to evaluate the effect of surface treatment of the cervical area of implant on bone regeneration in fresh extraction socket following implant installation. Materials and methods: The four minipigs, 18 months old and 30 kg weighted, were used. Four premolars of the left side of both the mandible and maxilla were extracted. ${\phi}$3.3 mm and 11.5 mm long US II plus implants (Osstem Implant co., Korea) with resorbable blasting media (RBM) treated surface and US II implants (Osstem Implant co., Korea) with machined surface at the top and RBM surface at lower portion were installed in the socket. Stability of the implant was measured with $Osstell^{TM}$ (Model 6 Resonance Frequency Analyser: Integration Diagnostics Ltd., Sweden). After 2 months of healing, the procedures and measurement of implant stability were repeated in the right side by same method of left side. At four months after first experiment, the animals were sacrificed after measurement of stability of all implants, and biopsies were obtained. Results: Well healed soft tissue and no mobility of the implants were observed in both groups. Histologically satisfactory osseointegration of implants was observed with RBM surface, and no foreign body reaction as well as inflammatory infiltration around implant were found. Furthermore, substantial bone formation and high degree of osseointegration were exhibited at the marginal defects around the cervical area of US II plus implants. However, healing of US II implants was characterized by the incomplete bone substitution and the presence of the connective tissue zone between the implant and newly formed bone. The distance between the implant platform (P) and the most coronal level of bone-to-implant contact (B) after 2 months of healing was $2.66{\pm}0.11$ mm at US II implants group and $1.80{\pm}0.13$mm at US II plus implant group. The P-B distance after 4 months of healing was $2.29{\pm}0.13$mm at US II implants group and $1.25{\pm}0.10$mm at US II plus implants group. The difference between both groups regarding the length of P-B distance was statistically significant(p<0.05). Concerning the resonance frequency analysis (RFA) value, the stability of US II plus implants group showed relatively higher RFA value than US II implants group. Conclusion: The current results suggest that implants with rough surface at the cervical area have an advantage in process of bone regeneration on defect around implant placed in a fresh extraction socket.

Isogeometric Analysis of Mindlin Plate Structures Using Commercial CAD Codes (상용 CAD와 연계한 후판 구조의 아이소-지오메트릭 해석)

  • Lee, Seung-Wook;Koo, Bon-Yong;Yoon, Min-Ho;Lee, Jae-Ok;Cho, Seon-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.3
    • /
    • pp.329-335
    • /
    • 2011
  • The finite element method (FEM) has been used for various fields like mathematics and engineering. However, the FEM has a difficulty in describing the geometric shape exactly due to its property of piecewise linear discretization. Recently, however, a so-called isogeometric analysis method that uses the non-uniform rational B-spline(NURBS) basis function has been developed. The NURBS can be used to describe the geometry exactly and play a role of basis functions for the response analysis. Nevertheless, constructing the NURBS basis functions in analysis is as costly as a meshing process in the FEM. Since the isogeometric method shares geometric data with CAD, it is possible to intactly import the model data from commercial CAD tools. In this paper, we use the Rhinoceros 3D software to create CAD models and export in the form of STEP file. The information of knot vectors and control points in the NURBS is utilized in the isogeometric analysis. Through some numerical examples, the accuracy of isogeometric method is compared with that of FEM. Also, the efficiency of the isogeometric method that includes the CAD and CAE in a unified framework is verified.

The effects of pear phenolic compound and herbal drugs on tension of the tracheal smooth muscle, eosinophil and interleukin-4 in mouse model of allergic bronchial asthma induced by ovalbumin (배(리(梨)) 추출 Phenolic Compound 및 길경(桔梗) 행인(杏仁) 배합 투여가 Ovalbumin으로 유발된 천식 동물 모델에서 기관지 평활근 장력, 호산구 및 IL-4에 미치는 영향)

  • Jeong, Jong-Gil;Youn, Dae-Hwan;Na, Chang-Su
    • The Korea Journal of Herbology
    • /
    • v.22 no.2
    • /
    • pp.25-33
    • /
    • 2007
  • Objectives : Oriental pear was used as treatment of asthma, control of blood pressure, diabetes in oriental medicine. The aim of this study was to observe the effects of Phenolic compound extracted from pear and herbal drugs to treat asthma. Methods : In order to study the effect of oral administration of phenolic compound extracted from pear and herbal drugs(Platycodon grandiflorum, Prunus armeniaca) on allergic asthma, mice were pre-treated by oral administration of the solution before antigen sensitization four times for 8 days. 2 days later, mice were actively sensitized with a subcutaneous injection of ovalbumin and 13 days later, they were provoked with ovalbumin aerosols. The animals were divided into four groups; Saline, orally administered saline. PC-A, orally administered Phenolic compound extracted from pear peel 10mg/kg/ml. PC-B, orally administered Phenolic compound extracted from pear peel and flesh 10mg/kg/ml. PC-C, orally administered pear 10m/kg/ml, Platycodon grandiflorum 24.4 mg/kg/ml and Prunus armeniaca 33.3 mg/kg/ml. Serum level of IgE, IL-4, cell numbers in the bronchoalveolar lavage fluid(BALF), and in vitro isometric contractile responses of the isolated tracheal smooth muscle(TSM) to acetylcholine(ACh, $0.1-1000{\mu}M$), KCl were measured. Results : Contractile responses of TSM to ACh were decreased in PC-A group at Ach 0.1, 0.3, 1 ${\mu}M$, decreased in PC-B at 0.1 ${\mu}M$ and decreased in PC-C at 0.1, 0.3, 1, 10, 30 ${\mu}M$. The maximal contractile response of TSM to KCl was decreased in PC-C group, The cell numbers of eosinophil in BALF were decreased in PC-C group, and those of macrophages in BALF were decreased in PC-A and PC-C group. Interleukin-4 in BALF was decreased in PC-A, PC-B, PC-C group. Conclusion : Based on the above results it is assumed that oral administration of phenolic compound extracted from pear and herbal drugs can help the treatment of deficiency allergic Asthma.

  • PDF

Positional symmetry of porion and external auditory meatus in facial asymmetry

  • Choi, Ji Wook;Jung, Seo Yeon;Kim, Hak-Jin;Lee, Sang-Hwy
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.37
    • /
    • pp.33.1-33.9
    • /
    • 2015
  • Background: The porion (Po) is used to construct the Frankfort horizontal (FH) plane for cephalometrics, and the external auditory meatus (EAM) is to transfer and mount the dental model with facebow. The classical assumption is that EAM represents Po by the parallel positioning. However, we are sometimes questioning about the possible positional disparity between Po and EAM, when the occlusal cant or facial midline is different from our clinical understandings. The purpose of this study was to evaluate the positional parallelism of Po and EAM in facial asymmetries, and also to investigate their relationship with the maxillary occlusal cant. Methods: The 67 subjects were classified into three groups. Group I had normal subjects with facial symmetry ($1.05{\pm}0.52mm$ of average chin deviation) with minimal occlusal cant (<1.5 mm). Asymmetry group II-A had no maxillary occlusal cant (average $0.60{\pm}0.36$), while asymmetry group II-B had occlusal cant (average $3.72{\pm}1.47$). The distances of bilateral Po, EAM, and mesiobuccal cusp tips of the maxillary first molars (Mx) from the horizontal orbital plane (Orb) and the coronal plane were measured on the three-dimensional computed tomographic images. Their right and left side distance discrepancies were calculated and statistically compared. Results: EAM was located 10.3 mm below and 2.3 mm anterior to Po in group I. The vertical distances from Po to EAM of both sides were significantly different in group II-B (p=0.001), while other groups were not. Interside discrepancy of the vertical distances from EAM to Mx in group II-B also showed the significant differences, as compared with those from Po to Mx and from Orb to Mx. Conclusions: The subjects with facial asymmetry and prominent maxillary occlusal cant tend to have the symmetric position of Po but asymmetric EAM. Some caution or other measures will be helpful for them to be used during the clinical procedures.

Purification and characterization of the chitinase from Bacillus subtilis JK-56 (Bacillus subtilis JK-56이 생산하는 chitinase isozyme의 정제와 특성 규명)

  • 전홍기;김낙원;정영기
    • Journal of Life Science
    • /
    • v.12 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Chitin, a $\beta$-1,4 polymer of N-acetyl-D-glucosamine, is one of the most abundant organic compounds in nature. Chitinase (EC 3.2.1.14) is an enzyme that degrades chitin to chito-oligosaccharides, diacetyl rhitobiose and N-acetyl-D-glucosamine. An extracellular chitinase-producing bacterial strain was isolated from soil and named to as Bacillus subtilis JK-56. Optimum culture condition of B. subtilis JK-56 for the production of chitinase was 1% chitin, 0.5% polypepton, 0.1% KCl, 0.05% MnS $O_4$.4$H_2O$, 37$^{\circ}C$, initial pH 7.0 and 40 hour culture time. When B. subtilis JK-56 was grown in the optimum medium, one major active band and two minor active bands were detected by native-PAGE and active staining of the gel. Among them, the major band was purified from the culture supernatant by 70% ammonium sulfate precipitation and native-PAGE with BIO-RAD Model 491 Prep-Cell and named as Chi-56A. Its molecular weight was estimated to be 53kDa monomer and the isoelectric point (pI) was pH 4.3. The pH and temperature for the optimum activity of Chi-56A were pH 6.0 and $65^{\circ}C$, respectively. Chi-56A was stable up to $65^{\circ}C$ and in alkaline region. Its $K_{m}$ value for colloidal chitin was 17.33g/L. HPLC analysis of the reaction products confirmed that Chi-56A was an exo type chitinase.e.

Developing the Service Quality Scale of Business Center: A New B2B Service Retailing Format (신 서비스유통포맷으로서의 비즈니스센터의 서비스품질 평가척도 개발)

  • Kim, Seung-Sub;Yoo, Dong-Keun;Lee, Phil-Soo
    • Journal of Distribution Science
    • /
    • v.12 no.11
    • /
    • pp.101-111
    • /
    • 2014
  • Purpose - This study aims to verify the construct of the service quality suitable to the characteristics of the business center, to develop the scale that can measure the service quality objectively, compare the diverse business centers in Korea, and present desirable methods of business center management and operation. Research design, data, and methodology - In the first stage, literature research and focus group interviews with current users and actual business experts of business centers were conducted. In addition, 69 early stage scale items were derived. In the second stage, a Delphi survey was conducted on the experts of business and academic circles. The measurement items in the early stage were supplemented and revised. The content validity rate (CVR) of 69 measures was computed and then the experts' opinions were used. As a result, the business center service quality scale, made up of 9 organizing factors and 36 measurement items, was constructed. In the third stage, a survey was conducted on the occupants who were currently using the business center. It was to confirm if the developed business center service quality scale could be actually utilized. The data of 435 samples collected were used. To refine the scale items, the exploratory factor analysis (EFA) was conducted repeatedly. Results - The business center service quality scale, made up of 8 factors and 33 items, was developed again. The 8 factors are reliability, speed, kindness, specialty, responsibility, appearance, convenience, and public interest. The reliability coefficient (Cronbach's Alpha) of each factor is greater than .7. Thus, it was confirmed that there was reliability in the measurement items. Further, the model suitability was verified using the confirmatory factor analysis (CFA), and the convergent validity and the discriminant validity were verified. This proved the construct validity. Through this process, the Korea Business Center Service Quality Scale was developed. Based on factor analysis, the developed business center service quality (BCSQ) scale consists of 4 aspects, 8 factors, and 33 items, comprising the "process quality" aspect: reliability (3 items), speediness (4 items), kindness (3 items) factors, the outcome quality aspect: expertise (3 items), responsibility (5 items) factors, the environment quality aspect: appearance (5 items), convenience (3 items) factors, and the public interest aspect: public interest (7 items) factor. However, according to CFA, the BCSQ scale consists of a total of 4 aspects, 8 factors, and 33 items, comprising the "process quality" aspect: reliability (3 items), speediness (3 items), kindness (3 items) factors, the outcome quality aspect: expertise (2 items), responsibility (4 items) factors, the environment quality aspect: appearance (3 items), convenience (2 items) factors, and the public interest aspect: public interest (3 items) factor. Conclusions - The BCSQ scale could serve as a diagnostic tool that will allow business center managers to determine service areas that are weak and in need of attention, and to improve the service quality of the business center.

Comparison of Natural Flow Estimates for the Han River Basin Using TANK and SWAT Models (TANK 모형과 SWAT 모형을 이용한 한강유역의 자연유출량 산정 비교)

  • Kim, Chul-Gyum;Kim, Nam-Won
    • Journal of Korea Water Resources Association
    • /
    • v.45 no.3
    • /
    • pp.301-316
    • /
    • 2012
  • Two models, TANK and SWAT (Soil and Water Assessment Tool) were compared for simulating natural flows in the Paldang Dam upstream areas of the Han River basin in order to understand the limitations of TANK and to review the applicability and capability of SWAT. For comparison, simulation results from the previous research work were used. In the results for the calibrated watersheds (Chungju Dam and Soyanggang Dam), two models provided promising results for forecasting of daily flows with the Nash-Sutcliffe model efficiency of around 0.8. TANK simulated observations during some peak flood seasons better than SWAT, while it showed poor results during dry seasons, especially its simulations did not fall down under a certain value. It can be explained that TANK was calibrated for relatively larger flows than smaller ones. SWAT results showed a relatively good agreement with observed flows except some flood flows, and simulated inflows at the Paldang Dam considering discharges from upper dams coincided with observations with the model efficiency of around 0.9. This accounts for SWAT applicability with higher accuracy in predicting natural flows without dam operation or artificial water uses, and in assessing flow variations before and after dam development. Also, two model results were compared for other watersheds such as Pyeongchang-A, Dalcheon-B, Seomgang-B, Inbuk-A, Hangang-D, and Hongcheon-A to which calibrated TANK parameters were applied. The results were similar to the case of calibrated watersheds, that TANK simulated poor smaller flows except some flood flows and had same problem of keeping on over a certain value in dry seasons. This indicates that TANK application may have fatal uncertainties in estimating low flows used as an important index in water resources planning and management. Therefore, in order to reflect actually complex and complicated physical characteristics of Korean watersheds, and to manage efficiently water resources according to the land use and water use changes with urbanization or climate change in the future, it is necessary to utilize a physically based watershed model like SWAT rather than an existing conceptual lumped model like TANK.

Development and Evaluation of Model-based Predictive Control Algorithm for Effluent $NH_4-N$ in $A^2/O$ Process ($A^2/O$ 공정의 유출수 $NH_4-N$에 대한 모델기반 예측 제어 알고리즘 개발 및 평가)

  • Woo, Dae-Joon;Kim, Hyo-Soo;Kim, Ye-Jin;Cha, Jae-Hwan;Choi, Soo-Jung;Kim, Min-Soo;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.25-31
    • /
    • 2011
  • In this study, model-based $NH_4-N$ predictive control algorithm by using influent pattern was developed and evaluated for effective control application in $A^2/O$ process. A pilot-scale $A^2/O$process at S wastewater treatment plant in B city was selected. The behaviors of organic, nitrogen and phosphorous in the biological reactors were described by using the modified ASM3+Bio-P model. A one-dimensional double exponential function model was selected for modeling of the secondary settlers. The effluent $NH_4-N$ concentration on the next day was predicted according to model-based simulation by using influent pattern. After the objective effluent quality and simulation result were compared, the optimal operational condition which able to meet the objective effluent quality was deduced through repetitive simulation. Next the effluent $NH_4-N$ control schedule was generated by using the optimal operational condition and this control schedule on the next day was applied in pilot-scale $A^2/O$ process. DO concentration in aerobic reactor in predictive control algorithm was selected as the manipulated variable. Without control case and with control case were compared to confirm the control applicability and the study of the applied $NH_4-N$control schedule in summer and winter was performed to confirm the seasonal effect. In this result, the effluent $NH_4-N$concentration without control case was exceeded the objective effluent quality. However the effluent $NH_4-N$ concentration with control case was not exceeded the objective effluent quality both summer and winter season. As compared in case of without predictive control algorithm, in case of application of predictive control algorithm, the RPM of air blower was increased about 9.1%, however the effluent $NH_4-N$ concentration was decreased about 45.2%. Therefore it was concluded that the developed predictive control algorithm to the effluent $NH_4-N$ in this study was properly applied in a full-scale wastewater treatment process and was more efficient in aspect to stable effluent.

A PHOTOELASTIC STUDY ON THE INITIAL STRESS DISTRIBUTION OF 3 TYPES TMA MULTI-VERTICAL LOOP ARCH WIRE (TMA wire로 제작된 3종류의 MVLAW(Multi-Vertical Loop Arch Wire)의 초기응력분포에 관한 광탄성학적 연구)

  • Lee, Hyeong-Chul;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.25 no.1 s.48
    • /
    • pp.73-85
    • /
    • 1995
  • Multi-Vertical Loop Arch Wire(MVLAW) is a kind of appliance for uprighting the mesially inclined posterior teeth axes simultaneously. In this study MVLAW was classified as 3 types by modifing the vertical loop design and named type A, B and C. Each MVLAW was fabricated from .017'x.025' TMA wire and preactivated at the distal end of the open vertical loop with 10 degree tip-back bend(type B has an electric welding stop at the distal end of each loop and type C has no electric welding stop). Type A MVLAW was preactivated at the apex of each open vertical loop with 10 degree tip-back bend(the electric welding stop of type A is positionod at the mesial side of each loop). The aim of the present study was to identify when and which MVLAW is more effective to correct the buccal segment axes simultaneously. The Photoelastic overview of the upper and lower right quadrant showed that stress concentrations were observed in its photoelastic model. The obtained results were as follows : 1. Higher level compression can be seen clearly at the distal curvature of the lower 1st and 2nd molar when A type MVLAW was applied without short class m elastic, but mild compression cannot be seen at the distal curvature of lower anterior teeth using the class m elastic. 2. Higher concentration was presented at the mesial curvature from the lower 1st premolar to the 2nd molar than the anterior teeth when B type MVLAW without short class III elastic was applied, but using the short class III elastic, higher concentration of compression was presented in the anterior teeth area. 3. Areas of higher compression and tension were not observed at the mesial and distal curvature of the entire 1ower teeth except lower central and lateral incisors in C type MVLAW without short class III elastic, but using the short class III elastic, higher concentration was seen at the mesial curvature of the lower 1st premolar and 1ower anterior teeth.

  • PDF

GAS-LIQUID TWO-PHASE HOMOGENEOUS MODEL FOR CAVITATING FLOW -Part II. HIGH SPEED FLOW PHENOMENA IN GAS-LIQUID TWO-PHASE MEDIA (캐비테이션 유동해석을 위한 기- 2상 국소균질 모델 -제2보: 기-액 2상 매체중의 고속유동현상)

  • Shin, B.R.;Park, S.;Rhee, S.H.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.91-97
    • /
    • 2014
  • A high resolution numerical method aimed at solving cavitating flow was proposed and applied to gas-liquid two-phase shock tube problem with arbitrary void fraction. The present method with compressibility effects employs a finite-difference 4th-order Runge-Kutta method and Roe's flux difference splitting approximation with the MUSCL TVD scheme. The Jacobian matrix from the inviscid flux of constitute equation is diagonalized analytically and the speed of sound for the two-phase media is derived by eigenvalues. So that the present method is appropriate for the extension of high order upwind schemes based on the characteristic theory. By this method, a Riemann problem for Euler equations of one dimensional shock tube was computed. Numerical results of high speed flow phenomena such as detailed observations of shock and expansion wave propagations through the gas-liquid two-phase media and some data related to computational efficiency are made. Comparisons of predicted results and solutions at isothermal condition are provided and discussed.