• Title/Summary/Keyword: mode behavior

Search Result 2,032, Processing Time 0.031 seconds

The Design and Implementation of Improved Anti-Collision Algorithm for Vehicle User Authentication System (차량 사용자 인증 시스템을 위한 향상된 충돌 방지 알고리즘의 설계 및 구현)

  • Kim, Kyeong-Seob;Lee, Yun-Seob;Choi, Sang-Bang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.1
    • /
    • pp.57-67
    • /
    • 2013
  • Because many of the FOB key, anti-collision algorithm for a seamless multi-access is applied to the smart-key system. In this paper, we have designed and implemented improved anti-collision algorithm that dramatically reduces the communication response time required in the user authentication process immediately after by dynamically changing the order in which the request of the user ID as the user ID on immediately before in the smart key system for vehicles that use many of the FOB key. In order to evaluate the performance of the system the improved anti-collision algorithm is applied, we show the behavior of the algorithm implemented in the state actually mounted on the vehicle and verify that communication response time required for many of the FOB key was reduced by about 33% compared to existing algorithms.

Compression Tests for Stiffened Steel Plate-Concrete Structures with Variation of B/t Ratio (스터드 간격과 강판두께의 비를 변수로 한 보강 강판-콘크리트 구조의 압축실험)

  • Choi, Byong Jeong;Han, Hong Soo;Kim, Won Ki;Lee, Seung Joon;Kim, Woo Bum
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.4
    • /
    • pp.549-559
    • /
    • 2008
  • The objective of this paper is to identify the compression forces and inelastic failure mode using stiffened steel plate-concrete structures. The compression tests were carried out for the three types of B/t ratios by 25, 33 and 50. The test results proved that the compressive strength of the stiffened SC structures can be estimated by the summation of the strengths both stiffened steel plate and concrete. The buckling of the steel plates had been occurred at the plates between studs. The empirical estimation of compressive strength for the stiffened SC structures under compressive loadings was suggested. The buckling behavior also compared with the results of the finite element analysis. The good agreement has been achieved between the experimental results and finite element results.

MODAL TESTING AND MODEL UPDATING OF A REAL SCALE NUCLEAR FUEL ROD

  • Park, Nam-Gyu;Rhee, Hui-Nam;Moon, Hoy-Ik;Jang, Young-Ki;Jeon, Sang-Youn;Kim, Jae-Ik
    • Nuclear Engineering and Technology
    • /
    • v.41 no.6
    • /
    • pp.821-830
    • /
    • 2009
  • In this paper, modal testing and finite element modeling results to identify the modal parameters of a nuclear fuel rod as well as its cladding tube are discussed. A vertically standing full-size cladding tube and a fuel rod with lead pellets were used in the modal testing. As excessive flow-induced vibration causes a failure in fuel rods, such as fretting wear, the vibration level of fuel rods should be low enough to prevent failure of these components. Because vibration amplitude can be estimated based on the modal parameters, the dynamic characteristics must be determined during the design process. Therefore, finite element models are developed based on the test results. The effect of a lumped mass attached to a cladding tube model was identified during the finite element model optimization process. Unlike a cladding tube model, the density of a fuel rod with pellets cannot be determined in a straightforward manner because pellets do not move in the same phase with the cladding tube motion. The density of a fuel rod with lead pellets was determined by comparing natural frequency ratio between the cladding tube and the rod. Thus, an improved fuel rod finite element model was developed based on the updated cladding tube model and an estimated fuel rod density considering the lead pellets. It is shown that the entire pellet mass does not contribute to the fuel rod dynamics; rather, they are only partially responsible for the fuel rod dynamic behavior.

Finding the Time Dependent K Least Time Paths in Intermodal Transportation Networks (복합교통망에서의 동적K최소시간경로탐색)

  • Jo, Jong-Seok;Sin, Seong-Il;Im, Gang-Won;Mun, Byeong-Seop
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.5 s.91
    • /
    • pp.77-88
    • /
    • 2006
  • The purpose of this study is to Propose the time dependent K-least time path algorithm applicable to a real-time based operation strategy in multi-modal transportation network. For this purpose, we developed the extended method based on entire path deletion method which was used in the static K-least time path algorithm. This method was applied to time dependent K-least time path algorithm to find k least time paths in order based on both time dependant mode-link travel time and transfer cost In particular, this algorithm find the optimal solution, easily describing transfer behavior, such as walking and waiting for transfer by applying a link-based time dependent label. Finally, we examined the verification and application of the Proposed algorithm through case study.

Sensitivity Analysis of Stochastic User Equilibrium in a Multi-Modal Network (다수단 확률적 사용자 균형의 민감도 분석)

  • Kim, Byeong-Gwan;Im, Yong-Taek
    • Journal of Korean Society of Transportation
    • /
    • v.28 no.5
    • /
    • pp.117-129
    • /
    • 2010
  • This study presents a sensitivity analysis method for stochastic user equilibrium of multi-modal network flows. We consider a multi-modal network consisting of a road network for passenger cars physically separated from a transit network for public transport. We first establish a sensitivity analysis method with respect to arbitrary link parameters and perform a sensitivity analysis with respect to link capacity and transit line frequency as practical link parameters. Next, We establish a sensitivity analysis method and perform the sensitivity analysis with respect to modal split by passenger car and public transit. As with the elasticity of economics, these results can be important information for analyzing changes in travel behavior due to the changes in operation and policy of transportation facilities, as well as for analyzing the effects of these operational changes and policies. These results also can be utilized as a tool to constitute a multi-modal network design problem by using cooperative game theory.

A Study on Stress Corrosion Cracking Evaluation with Material Degradation of High Temperature Components (고온부재의 재질열화에 따른 응력부식균열 평가에 관한 연구)

  • Park, Jong-Jin;Yu, Ho-Seon;Jeong, Se-Hui
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.4
    • /
    • pp.1123-1132
    • /
    • 1996
  • It has been reported that high temperature structural components represent the phenomenon of material degradation according to a long term service under high temperature and pressure. Especially, fossile power plant components using the fossil fuel and heavy oil are affected by dewpoint corrosion of $H_2SO_4$produced during a combustion. Therefore, the service materials subjected to high temperature and pressure may occur the stress corrosion cracking. The object of this paper is to investigate SCC susceptibility according to the material degradation of the high temperature structural materials in dewpoint corrosive environment-$H_2SO_4$.The obtained results are summarized as follows : 1) In case of secondary superheater tube, the fractograph of dimple is observed at the concentration of $H_2SO_4$-5%. When the concentration of $H_2SO_4$ is above 10%, the fracture mode is shifted from a transgranular fracture to an quasi-intergranular fracture according to the increment of concentration. 2) In the relationship between [$\Delta$DBTT]$_sp$ and SCC susceptibility, it is confirmed that the greater material degradation degree is, the higher SCC susceptibility is. In addition, it can be known that SP test is useful test method to evaluate SCC susceptibility for high temperature structural components. 3) When [$\Delta$DBTT]$_sp$ is above 17$17^{\circ}C$ the SCC fracture behavior is definitely observed with SCC susceptibility of above 0.4.

Radioiodine Therapy For Differentiatd Thyroid Cancer (분화성 갑상선암의 방사성옥소 치료)

  • Hong, Sung-Woon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.4
    • /
    • pp.265-275
    • /
    • 2000
  • The thyroid gland is an interesting endocrine organ where a spectrum of tumors with different behavior arise. At one end of spectrum there is differentiated thyroid carcinoma (DTC) with excellent prognosis, whereas at the other end of the spectrum is anaplastic thyroid cancer which has universally poor outcome. Radioiodine (I-131) therapy has been in use for the treatment of thyroid diseases since 1946. It was introduced by Seidlin et al. 1) Although the use of I-131 has been vouge for a long time, its use in therapy for well differentiated thyroid cancer is still controversial 2). This is because, thyroid cancers (TC) are generally slow growing tumors, with low mortality and normal spans of survival. To record recurrence and mortality, long term follow up studies over a period of two to three decades are needed to establish definite conclusions on the acceptable mode of treatment The incidence of the disease being very low a large number of cases needed to establish a meaningful statistical data is lacking as most published reports feat with small series. Here again in the problem encountered are the differing protocols for treatment with I-131, the indications for treatment which may include or exclude ablation of residual thyroid tissue, cervical nodal and distal metastases. The dosage of I-131 used for ablation of residual thyroid tissue and metastatic disease also vary. The most reliable conclusion regarding I-131 treatment are obtained from studies reported on a large series of patients followed over a period of 2 decades or more from a single institute with a more or less unchanged protocol of management.

  • PDF

Fracture Behavior of CFRP by Time-Frequency Analysis Method (시간-주파수 해석법에 의한 CFRP의 파괴 거동)

  • Nam, Ki-Woo;Ahn, Seok-Hwan;Lee, Sang-Kee;Kim, Hyun-Soo;Moon, Chang-Kwon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.1
    • /
    • pp.39-45
    • /
    • 2001
  • Fourier transform has been one of the most common tools to study the frequency characteristics of signals. With the Fourier transform alone, however, it is difficult to tell whether signal's frequency contents evolve in time or not. Except for a few special cases, the frequency contents of most signals encountered in the real world change with time. Time-frequency analysis methods are developed recently to overcome the drawbacks of Fourier transform, which can represent the information of signals in time and frequency at the same time. In this study, damage process of a cross-ply carbon fiber reinforced plastic (CFRP) under monotonic tensile loading was characterized by acoustic emission. Different kinds of CFRP specimens were used to determine the characteristics of AE signals. Time-frequency analysis methods were employed for the analysis of fracture mechanisms in CFRP such as mix cracking, debonding, fiber fracture and delamination.

  • PDF

Experimental study on the damping estimation of the 5$\times$5 rod bundle (5$\times$5 봉다발의 감쇄추정을 위한 실험적 연구)

  • Lee, Kang-Hee;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.503-506
    • /
    • 2005
  • The PWR Nuclear Fuel assembly consists of more than 250 fuel rods that are supported by leaf springs in the cells of more than 10 Spacer Grids (SG) along the rod length. Since it is not easy to conduct mechanical tests on a full-scale model basis, the small-scaled rod bundle (5$\times$5) is generally used for various performance tests during the development stage. As one of the small-scaled tests, a flow test should be carried out in order to verify the performance of the spacer grid like the coolant mixing performance and to obtain the Flow-Induced Vibration (FIV) characteristics of the rod bundle over the specified flow range. A vibration test should be also performed to obtain the modal parameters of the bundle prior to the flow test. In this study, we want to develop the estimation procedure of the damping ratio for the small scaled test bundle. For the damping factor of the rod bundle and the grid case at the first vibration mode, as one of the vibration tests, a so-called pluck testing has been performed in air as a preliminary test prior to in-flow damping measurement test. Logarithmic decrement method is used for calculation of the damping ratio. Estimated damping ratio of the rod bundle is about 0.7% with reasonable error of 2% for the previous results. Nonlinear behavior of the rod bundle might be stem mainly Iron the rod-grid support configuration.

  • PDF

Concrete pavement monitoring with PPP-BOTDA distributed strain and crack sensors

  • Bao, Yi;Tang, Fujian;Chen, Yizheng;Meng, Weina;Huang, Ying;Chen, Genda
    • Smart Structures and Systems
    • /
    • v.18 no.3
    • /
    • pp.405-423
    • /
    • 2016
  • In this study, the feasibility of using telecommunication single-mode optical fiber (SMF) as a distributed fiber optic strain and crack sensor was evaluated in concrete pavement monitoring. Tensile tests on various sensors indicated that the $SMF-28e^+$ fiber revealed linear elastic behavior to rupture at approximately 26 N load and 2.6% strain. Six full-scale concrete panels were prepared and tested under truck and three-point loads to quantify the performance of sensors with pulse pre-pump Brillouin optical time domain analysis (PPP-BOTDA). The sensors were protected by precast mortar from brutal action during concrete casting. Once air-cured for 2 hours after initial setting, half a mortar cylinder of 12 mm in diameter ensured that the protected sensors remained functional during and after concrete casting. The strains measured from PPP-BOTDA with a sensitivity coefficient of $5.43{\times}10^{-5}GHz/{\mu}{\varepsilon}$ were validated locally by commercial fiber Bragg grating (FBG) sensors. Unlike the point FBG sensors, the distributed PPP-BOTDA sensors can be utilized to effectively locate multiple cracks. Depending on their layout, the distributed sensors can provide one- or two-dimensional strain fields in pavement panels. The width of both micro and major cracks can be linearly related to the peak strain directly measured with the distributed fiber optic sensor.