• Title/Summary/Keyword: modal strain

Search Result 199, Processing Time 0.031 seconds

Vibration Exciter Design for Flow Resonance with a Displacement Estimator Using Strain Gage (스트레인 게이지 변위추정 센서를 사용한 유동공진 가진기 설계)

  • Nam, Yun-Su;Choe, Jae-Hyeok;Gang, Byeong-Ha
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.9
    • /
    • pp.1874-1881
    • /
    • 2002
  • Heat dissipation technology using the flow resonant phenomenon is a kind of a new concept in the heat transfer area. A vibration exciter is needed to enhance air flow mixing which has the natural shedding frequency of thermal system. A mechanical vibrating device for the air flow oscillation is introduced, which is driven by a moving coil actuator with a displacement estimator using strain gage. An analytical dynamic model for this mechanical vibration exciter is presented and its validity is checked by the comparison with experimental data. Values of some unknown system parameters in the analytic model are estimated through the system identification approach. Based on this mathematical model, the vibration exciter using strain displacement estimator is developed. During the experimental verification phase, it turns out the high modal resonant characteristics of a vibrating plate are a major barrier against obtaining a high bandwidth vibration exciter.

Extension of indirect displacement estimation method using acceleration and strain to various types of beam structures

  • Cho, Soojin;Sim, Sung-Han;Park, Jong-Woong;Lee, Junhwa
    • Smart Structures and Systems
    • /
    • v.14 no.4
    • /
    • pp.699-718
    • /
    • 2014
  • The indirect displacement estimation using acceleration and strain (IDEAS) method is extended to various types of beam structures beyond the previous validation on the prismatic or near-prismatic beams. By fusing different types of responses, the IDEAS method is able to estimate displacements containing pseudo-static components with high frequency noise to be significantly reduced. However, the concerns to the IDEAS method come from possible disagreement of the assumed sinusoidal mode shapes to the actual mode shapes, which allows the IDEAS method to be valid only for simply-supported prismatic beams and limits its applicability to real world problems. In this paper, the extension of the IDEAS method to the general types of beams is investigated by the mathematical formulation of the modal mapping matrix only for the monitored substructure, so-called monitoring span. The formulation particularly considers continuous and wide beams to extend the IDEAS method to general beam structures that reflect many real bridges. Numerical simulations using four types of beams with various irregularities are presented to show the effectiveness and accuracy of the IDEAS method in estimating displacements.

Performance evaluation of smart prefabricated concrete elements

  • Zonta, Daniele;Pozzi, Matteo;Bursi, Oreste S.
    • Smart Structures and Systems
    • /
    • v.3 no.4
    • /
    • pp.475-494
    • /
    • 2007
  • This paper deals with the development of an innovative distributed construction system based on smart prefabricated concrete elements for the real-time condition assessment of civil infrastructure. So far, two reduced-scale prototypes have been produced, each consisting of a $0.2{\times}0.3{\times}5.6$ m RC beam specifically designed for permanent instrumentation with 8 long-gauge Fiber Optic Sensors (FOS) at the lower edge. The sensing system is Fiber Bragg Grating (FBG)-based and can measure finite displacements both static and dynamic with a sample frequency of 625 Hz per channel. The performance of the system underwent validation in the laboratory. The scope of the experiment was to correlate changes in the dynamic response of the beams with different damage scenarios, using a direct modal strain approach. Each specimen was dynamically characterized in the undamaged state and in various damage conditions, simulating different cracking levels and recurrent deterioration scenarios, including cover spalling and corrosion of the reinforcement. The location and the extent of damage are evaluated by calculating damage indices which take account of changes in frequency and in strain-mode-shapes. The outcomes of the experiment demonstrate how the damage distribution detected by the system is fully compatible with the damage extent appraised by inspection.

Damage detection for beam structures based on local flexibility method and macro-strain measurement

  • Hsu, Ting Yu;Liao, Wen I;Hsiao, Shen Yau
    • Smart Structures and Systems
    • /
    • v.19 no.4
    • /
    • pp.393-402
    • /
    • 2017
  • Many vibration-based global damage detection methods attempt to extract modal parameters from vibration signals as the main structural features to detect damage. The local flexibility method is one promising method that requires only the first few fundamental modes to detect not only the location but also the extent of damage. Generally, the mode shapes in the lateral degree of freedom are extracted from lateral vibration signals and then used to detect damage for a beam structure. In this study, a new approach which employs the mode shapes in the rotary degree of freedom obtained from the macro-strain vibration signals to detect damage of a beam structure is proposed. In order to facilitate the application of mode shapes in the rotary degree of freedom for beam structures, the local flexibility method is modified and utilized. The proposed rotary approach is verified by numerical and experimental studies of simply supported beams. The results illustrate potential feasibility of the proposed new idea. Compared to the method that uses lateral measurements, the proposed rotary approach seems more robust to noise in the numerical cases considered. The sensor configuration could also be more flexible and customized for a beam structure. Primarily, the proposed approach seems more sensitive to damage when the damage is close to the supports of simply supported beams.

Stability augmentation of helicopter rotor blades using passive damping of shape memory alloys

  • Yun, Chul-Yong;Kim, Dae-Sung;Kim, Seung-Jo
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.7 no.1
    • /
    • pp.137-147
    • /
    • 2006
  • In this study, shape memory alloy damper with characteristics of pseudoelastic hysteresis for helicopter rotor blades are investigated. SMAs can be available in damping augmentation of vibrating structures. SMAs show large hysteresis in the process of pseudoelastic austenite-martensite phase transformation which takes place while subjected to loading above the austenite finish temperature. Since SMAs display pseudoelastic hysteresis behavior over large strain ranges, a significant amount of energy dissipation is possible. A damper can be designed with SMA wires prestressed to a baseline level somewhere in the middle of the pseudoelastic stress range. An experimental study of the effects of pre-strain and cyclic strain amplitude as well as frequency on the damping behavior of pseudoelastic shape memory alloy wires are performed. The effects of the shape memory alloy damper on aeroelastic and ground resonance stability of helicopter are studied. In aeroelastic stability, the dynamic characteristics of blades related to pitch angle and the amplitude of lag motion for the rotor equipped with SMA damper were examined. The performance of SMA damper on ground resonance instability are presented through the frequencies and modal damping with respect to rotating speed.

An Experimental Study on Placements and Thickness of Damping Material for Vibration Control of Automotive Roof (자동차 루프의 진동제어를 위한 제진재의 위치 및 두께에 대한 실험적 연구)

  • Lee, Jeong-Kyun;Kim, Chan-Mook;Sa, Jong-Sung
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.31-37
    • /
    • 2005
  • This paper presents an experimental study on vibration characteristics of an automotive roof with damping material. The goal of the study is to extract modal parameters(natural frequency, loss factor, and mode shape) of automotive roof with damping materials treatment. To determine the effective positions and thickness of the damping material on a roof, vibration tests have been carried out for six cases; an aluminum plate with damping material on maximum strain energy positions, and an aluminum plate with damping material on nodal lines. From the result of aluminum plate, it is found that the damping material should be placed on the location with maximum strain energy part. For the automotive roof, patches of constrained damping material, which has two different density, have been attached to the positions of the maximum strain energy with four kinds of thicknesses. This paper shows that the proper positioning of the damping material is very important and the effective thickness is about twice that of the roof panel.

Shaking table test of liquid storage tank with finite element analysis considering uplift effect

  • Zhou, Junwen;Zhao, Ming
    • Structural Engineering and Mechanics
    • /
    • v.77 no.3
    • /
    • pp.369-381
    • /
    • 2021
  • The seismic responses of elevated tanks considering liquid-structure interaction are presented under horizontal earthquake. The scaled model tank is fabricated to study the dynamic responses of anchored tank and newly designed uplift tank with replaced dampers. The natural frequencies for structural mode are obtained by modal analysis. The dynamic responses of tanks are completed by finite element method, which are compared with the results from experiment. The displacement parallel and perpendicular to the excitation direction are both gained as well as structural acceleration. The strain of tank walls and the axial strain of columns are also obtained afterwards. The seismic responses of liquid storage tank can be calculated by the finite element model effectively and the results match well with the one measured by experiment. The aim is to provide a new type of tank system with vertical constraint relaxed which leads to lower stress level. With the liquid volume increasing, the structural fundamental frequency has a great reduction and the one of uplift tank are even smaller. Compared with anchored tank, the displacement of uplift tank is magnified, the strain for tank walls and columns parallel to excitation direction reduces obviously, while the one perpendicular to earthquake direction increases a lot, but the values are still small. The stress level of new tank seems to be more even due to uplift effect. The new type of tank can realize recoverable function by replacing dampers after earthquake.

An Analysis of Dynamic Characteristics of Bolted Lap Joints with Viscoelastic Layers (점탄성재 삽입시 볼트랩 죠인트의 동특성 해석)

  • 박명균;박세만;최영식;박상규
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.1
    • /
    • pp.172-178
    • /
    • 2003
  • Two types of bolted lap joints, one with a viscoelastic layer and the other without the viscoelastic layer were chosen to analyze the dynamic characteristics of the joints with the mechanical properties of the bolts in the joints are considered as computational variables. The finite element method was used along with the modal testing to verify the PEM model. The results in the bolted lap joints reveal that the higher the Young's modulus for the bolts we use the higher the natural frequencies we obtain fur the joints. However, the natural frequency differences in the first and second mode are not substantial but become noticeable in the higher modes. Lower natural frequencies were obtained for the bolted lap joints with the viscoelastic layer when compared with those of the bolted lap joints without the viscoelastic layer. And the differences in the natural frequencies for the two types of joints are relatively small in the first and second mode whereas in the higher mode the differences become significant. The loss factors were observed to be significant especially in the second mode for the bolted lap joints with the viscoelastic layer.

Vibration-Based Damage Monitoring in Model Plate-Girder Bridges under Uncertain Temperature Conditions (불확실한 온도 조건하의 모형 강 판형교의 진동기반 손상 모니터링)

  • Park, Jae-Hyung;Hong, Dong-Soo;Cho, Hyun-Man;Kim, Jeong-Tae
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.75-82
    • /
    • 2008
  • A vibration-based damage-monitoring scheme is proposed that would generate an alarm showing the occurrence and location of damage under temperature-induced uncertainty conditions. Experiments on a model plate-girder bridge are described, for which a set of modal parameters was measured under uncertain temperature conditions. A damage-alarming model is formulated to statistically identify the occurrence of damage by recognizing the patterns of damage-driven changes in the natural frequencies of the test structure and by distinguishing temperature-induced off-limits. A damage index method based on the concept of modal strain energy is implemented in the test structure to predict the location of damage. In order to adjust for the temperature-induced changes in the natural frequencies that are used for damage detection, a set of empirical frequency correction formulas is analyzed from the relationship between the temperature and frequency ratio.

Seismic Behavior of Steel Structure with Added Viscoelastic Dampers under Strong Earthquake Ground Motions (점탄성 감쇠기를 설치한 강구조 건물의 강지진 하중에 의한 거동 연구)

  • Oh, Soon Taek
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.111-120
    • /
    • 1993
  • This paper summarizes an experimental and analytical study on the application of viscoelastic dampers as energy dissipation devices in structural applications. It can be concluded the viscoelastic dampers are effective in reducing excessive vibrations of structures under strong earthquake ground motions. It is also found that the modal strain energy method can be used to reliably predict the equivalent structural damping, and the seismic response of a viscoelastically damped structure can be accurately estimated by conventional modal analysis techniques. Based on the above studies, a design procedure for viscoelastically damped structures is presented. This design procedure fits naturally into the conventional structural design flow chart by including damping ratio as an additional design parameter.

  • PDF