• Title/Summary/Keyword: modal method

Search Result 1,852, Processing Time 0.026 seconds

Determination of dielectric property of subsurface by dispersive guided GPR wave (레이다파의 분산성 가이드 현상을 이용한 지하 물성 계산)

  • Yi, Myeong-Jong;Endres, Anthony L.;Kim, Jung-Ho
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.25-30
    • /
    • 2006
  • When wet soil overlies dry soil, which can be found in the infiltration test, the radar wave is not attenuated and guided within wet soil layer. This phenomenon is known to be the dispersive guided wave and happens when the thickness of upper wet layer is less than or comparable to the wavelength of radar wave. In this study, we have conducted the FDTD modeling and obtained the velocity dispersion curve to identify the dispersive guided wave through F-K analysis. This guided wave can be explained by modal propagation theory and a simple inversion code was developed to obtain the two layer's dielectric constants as well as layer thickness. By inverting the dispersion curve from synthetic modeling data, we could obtain the accurate dielectric constants and layer thickness. Moreover, we could enhance the accuracy by including the higher mode data. We expect this method will be very useful to get the quantitative property of subsurface when the condition is similar.

  • PDF

Study on Eigenvalue Analysis for a Towed Cable - Free Boundary at the Bottom End (예인되는 케이블의 고유치 해석에 관한 연구 - 하부 끝단 자유 경계조건)

  • Jung, Dong-Ho;Kim, Hyeon-Ju;Moon, Deok-Soo;Lee, Seung-Won
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.1
    • /
    • pp.74-80
    • /
    • 2009
  • In this study, the static and modal analyses to find the characteristic of eigenvalues for a towed cable were with a free boundary condition at the bottom end carried out with numerical study. The resulting numerical code with finite element method was used to study sample problems for a cable with towing speeds. After tracing the equilibrium state with a towing speed through the static analysis, modal analysis on the basis of static results was performed. The static top tension for a critical towing speed is nearly 50 percent of what it was for a free hanging pipe. From static analyses, it is found that towing speed has a noticeable effect on top tension of a towed pipe. At a high towing speed, differences between the first and second periods become larger. Compared to the fundamental period for a free hanging pipe, that for a towed pipe with a critical towing speed is approximately 1.4 times larger. This result is very important point in that the lock in condition and tension of the towed cable system with top excitation can be predicted. The corrected close form solution to solve natural periods for a towed cable was presented in this study. The code is validated by comparison of the results of theoretical and numerical studies. Two results were in very good agreement. This study can contribute to predicting the lock-in condition and tension for a towed cable or pipe with top excitation.

Influence of the Francis Turbine location under vortex rope excitation on the Hydraulic System Stability

  • Alligne, S.;Nicolet, C.;Allenbach, P.;Kawkabani, B.;Simond, J.J.;Avellan, F.
    • International Journal of Fluid Machinery and Systems
    • /
    • v.2 no.4
    • /
    • pp.286-294
    • /
    • 2009
  • Hydroelectric power plants are known for their ability to cover variations of the consumption in electrical power networks. In order to follow this changing demand, hydraulic machines are subject to off-design operation. In that case, the swirling flow leaving the runner of a Francis turbine may act under given conditions as an excitation source for the whole hydraulic system. In high load operating conditions, vortex rope behaves as an internal energy source which leads to the self excitation of the system. The aim of this paper is to identify the influence of the full load excitation source location with respect to the eigenmodes shapes on the system stability. For this, a new eigenanalysis tool, based on eigenvalues and eigenvectors computation of the nonlinear set of differential equations in SIMSEN, has been developed. First the modal analysis method and linearization of the set of the nonlinear differential equations are fully described. Then, nonlinear hydro-acoustic models of hydraulic components based on electrical equivalent schemes are presented and linearized. Finally, a hydro-acoustic SIMSEN model of a simple hydraulic power plant, is used to apply the modal analysis and to show the influence of the turbine location on system stability. Through this case study, it brings out that modeling of the pipe viscoelastic damping is decisive to find out stability limits and unstable eigenfrequencies.

Vibration Analysis of PCB Manufacturing System Using Maskless Exposure Method (Maskless 방식을 이용한 PCB생산시스템의 진동 해석)

  • Jang, Won-Hyuk;Lee, Jae-Mun;Cho, Myeong-Woo;Kim, Joung-Su;Lee, Chul-Hee
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.12
    • /
    • pp.1322-1328
    • /
    • 2009
  • This paper presents vibration analysis of maskless exposure module in printed circuit board(PCB) manufacturing system. In order to complete exposure process in PCB, masking type module has been widely used in electronics industries. However, masking process confronts some limitations of application due to higher production cost for masking as well as lower printing resolution. Therefore, maskless exposure module is started to be in the spotlight for flexible production system to meet the needs of fabrication in variable patterns at low cost. Since maskless exposure process adopts direct patterning to PCB, vibration problems become more critical compared to conventional masking type process. Moreover, movements of exposure engine as well as stage generate vibration sources in the system. Thus, it is imperative to analyze the vibration characteristics for the maskless exposure module to improve the quality and accuracy of PCB. In this study, vibration analysis using the finite element analysis is conducted to identify the critical structural parts deteriorating vibration performance. Also, Experimental investigations are conducted by single/dual encoder measurement process under the operating module speed. Measurement points of vibration are selected by three places, which are base of stage, exposure engine and top of stage, to check the effect of vibration from the exposure engine. Comparisons between analysis results and experimental measurement are conducted to confirm the accuracy of analysis results including the developed FE model. Finally, this studies show feasibility of optimal design using the developed FE analysis model.

Structural Performance Tests of Down Scaled Composite Wind Turbine Blade using Embedded Fiber Bragg Grating Sensors

  • Kim, Sang-Woo;Kim, Eun-Ho;Rim, Mi-Sun;Shrestha, Pratik;Lee, In;Kwon, Il-Bum
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.12 no.4
    • /
    • pp.346-353
    • /
    • 2011
  • In this study, the structural performance tests, i.e., static tests and dynamic tests of the composite wind turbine blade, were carried out by using the embedded fiber Bragg grating (FBG) sensors. The composite wind turbine blade used in the test is the 1/23 scale of the 750 kW composite blade. In static tests, the deflections along the blade were evaluated. Evaluations were carried out with simple beam theory and quadratic fitting method by using the embedded FBG sensors to predict the structural behavior with respect to the load. The deflections were compared to those obtained from the laser displacement sensor and electric strain gauges. They showed good agreement. Modal tests were performed to investigate the dynamic characteristics using the embedded FBG sensors. The natural frequencies obtained from the FBG sensors corresponding to the nine mode shapes of the blade were compared to those from the laser Doppler vibrometer. They were found to be consistent with each other. Therefore, it is concluded that the embedded FBG sensors have a great capability for measuring the structural performances of the composite wind turbine blade when structural performance tests are carried out.

Research on the Intention to Adopt a Railway as an International Transportation Mode in Korea: A Focus on Transcontinental Railways (KTAR) (국제 운송수단으로서의 철도 선택에 관한 연구 - 대륙횡단철도 선택 의도를 중심으로 -)

  • Choi, Kyoung-Suk;Song, Chae-Hun
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.2
    • /
    • pp.205-215
    • /
    • 2012
  • The purpose of this research is to identify the factors affecting the intention to adopt a transcontinental railway in Korea. We develop an empirically testable model that demonstrates the effects of factors including cost, service, and efficiency of railway transportation, on modal shift intention to railway, attitude of a Railway, and intention to adopt a Transcontinental Railway (KTAR) as a railway transportation mode in the end. A survey method enables us to analyze the model with a structural equation modeling. The empirical analysis reveals that two most influential factors-the modal shift to railway transportation and the attitude of a Railway-play roles in determining intention to adopt the Transcontinental Railway (KTAR). Of the factors of transportation mode, transportation cost has a greater impact than transportation service and transportation efficiency on the intention to adopt a Transcontinental Railway (KTAR).

Design of Friction Dampers installed at a Multi-Story Building under Seismic Load (지진하중을 받는 다층 건물에 설치된 마찰감쇠기 설계)

  • Seong, Ji-Young;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.4
    • /
    • pp.457-462
    • /
    • 2011
  • In this study, a simplified design procedure for friction dampers of a multi-story structure in order to reduce seismic response is proposed. To get insight for control effect of the structure with friction dampers is difficult, because of a nonlinear characteristic by a friction damper. Since a control force of a friction damper is influenced by coupling velocity between floors, adjoining modes are coupled. Thus structural response are derived by assuming steady-state response in resonance. As it is impossible that an exact solution is obtained for seismic load, first, a closed form solution can be achieved under harmonic vibration. Second, to convert a three-story building into a single-degree-of-freedom(SDOF) structure, modal analysis is performed. Third, an equivalent damping ratio is derived with utilizing closed form solution. And response reducing factor is proposed by it. Finally, friction force of a damper is designed for using response reducing factor, and then designed dampers are verified for seven seismic data. The nonlinear analysis results confirm the validity of the proposed procedure.

Seismic Behavior of A 2/5-Scale Steel Structure with Added Viscoelastic Dampers (점탄성 감쇠기를 설치한 2/5 축척 강구조물의 지진하중에 의한 거동연구)

  • Oh, Soon-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.8 no.1
    • /
    • pp.80-87
    • /
    • 1993
  • This paper summarizes an experimental and analytical study on the application of viscoelastic dampers as energy dissipation devices in structural applications. Shaking table tests are carried out on the viscoelastically damped structure and the obtained structural responses are compared to those of the inelastic analysis results for the same test structure with no dampers added. It can be concluded the viscoelastic dampers are effective in reducing excessive vibrations of structures under strong earthquake ground motions. It is also observed that the increase in structure's stiffness by the addition of dampers can not contribute to improving the seismic response of a structure. In general. the reduction of the seismic response by adding the dampers to the structure is mostly resulted from the increased damping effect. It is found that the modal strain energy method can be used to reliably predict the equivalent structural damping. and the seismic response of a viscoelastically damped structure can be accurately estimated by conventional modal analysis techniques.

  • PDF

Dynamic Parameter Estimation of a CANDU Type Containment Using Ambient Vibration Measurements (상시진동을 이용한 CANDU형 격납건물의 동적파라미터 산정)

  • Choi, Sanghyun;Park, Sooyong;Hyun, Chang-Hun;Kim, Moon-Soo
    • Journal of the Society of Disaster Information
    • /
    • v.8 no.2
    • /
    • pp.188-196
    • /
    • 2012
  • Dynamic parameters such as natural frequencies can provide global stiffness information of a structure, and thus be utilized in monitoring structural integrity of large structures such as a containment. To identify the dynamic parameters without interrupting normal operation, a modal analysis method based on ambient vibration measurements should be applied. In this study, dynamic parameters of the containment of Wolsong Unit 2 are identified using ambient vibration measurement data. The feasibility of the study is verified using a numerical model for the containment. From the modal analysis, dynamic parameters of the containment with acceptable correlation to analytical modes can be estimated.

Facial Features and Motion Recovery using multi-modal information and Paraperspective Camera Model (다양한 형식의 얼굴정보와 준원근 카메라 모델해석을 이용한 얼굴 특징점 및 움직임 복원)

  • Kim, Sang-Hoon
    • The KIPS Transactions:PartB
    • /
    • v.9B no.5
    • /
    • pp.563-570
    • /
    • 2002
  • Robust extraction of 3D facial features and global motion information from 2D image sequence for the MPEG-4 SNHC face model encoding is described. The facial regions are detected from image sequence using multi-modal fusion technique that combines range, color and motion information. 23 facial features among the MPEG-4 FDP (Face Definition Parameters) are extracted automatically inside the facial region using color transform (GSCD, BWCD) and morphological processing. The extracted facial features are used to recover the 3D shape and global motion of the object using paraperspective camera model and SVD (Singular Value Decomposition) factorization method. A 3D synthetic object is designed and tested to show the performance of proposed algorithm. The recovered 3D motion information is transformed into global motion parameters of FAP (Face Animation Parameters) of the MPEG-4 to synchronize a generic face model with a real face.