• Title/Summary/Keyword: mock test

Search Result 461, Processing Time 0.027 seconds

Construction of Aluminum Curtain Wall with 3D Elevation for TRUTEC Building (트루텍 빌딩의 3차원 입체 커튼월 시공)

  • Park, Choel;Hong, Doo-Pyo
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.119-122
    • /
    • 2007
  • TRUTEC building, which is located at DMC B block is zone, is just one the office building in Soeul. TRUTEC building is designed by Barkow Leibinger Architeken in Germany, has 5 stories under and 12 stories above and has been finished with the unique three dimensional curtain wall unit. Big trial to make unique elevation succeeded as getting rid of the typical plain curtain wall unit. In addition, aluminum bars are treated by the latest CNC machine in order to achieve 3D section. Construction of curtain wall is highly focused from the moment of contract to keep the schedule because the contract period is 18 months. Regular design meeting and technical meeting between stakeholders including construction manager, designer, engineer, consultant and so on have been held during the construction to minimize the risks from the unique elevation and trial. Step by step mock-up test (design mock-up and visual mock-up on site) has been performed before functional mock-up test.

  • PDF

The Mock-up Test for the Hot Weathered High Strength Concrete (고강도 콘크리트의 하절기 적용을 위한 실물모형시험)

  • Shon, Myung-Soo;Kim, Tae-Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.442-445
    • /
    • 2004
  • The mock-up test was carried out to solve several problems of the hot weathered high strength concrete. The workability of concrete could be guaranteed by using high range water reducer containing polycarboxylic acid. The compressive strength calculation by rebound value of Schumidt hammer underestimated the actual strength of concrete structure. The temperature of concrete should be lowered by control of raw material temperature and transportation.

  • PDF

Effect of Replacement of 5~13mm Recycled Coarse Aggregates on Field Applicability of the Concrete through Mock-up Test (목업 시험을 통한 5~13mm 순환 굵은골재 치환 사용이 콘크리트의 현장적용성에 미치는 영향 고찰)

  • Han, Min-Cheol;Song, Young-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.1
    • /
    • pp.59-67
    • /
    • 2017
  • The objective of this paper is to investigate experimentally the effect of replacement of recycled coarse aggregates with 5~13mm in size on a field applicability of concretes through Mock-up test. Seven different mock-up specimens were prepared with the size of $1200{\times}800{\times}800mm$ simulating column and wall. For the concrete mixtures, 24MPa, 27MPa and 40MPa of nominal strength were adopted with 30% and 70%(only for 24MPa) of 5~13mm recycled coarse aggregate (RCA) replacement and without 5~13mm RCA(Plain). For test items, slump, slump flow, compressive strength with different curing conditions, core drilling, rebound numbers and drying shrinkage were measured. Test results indicated that 30% of 5~13 mm RCA replacement resulted in increase in slump, slump flow and resistance against segregation, while air contents decreased compared to those of plain mixture. Compressive strength of concrete with 30% of 5~13mm RCA was shown to be higher than that of plain mixture due to optimum packing effect associated with presence of well graded aggregates. Rebound number of the mock-up specimen with 30% of 5~13mm RCA had lower fluctuation according to hitting location than that of plain mock-up specimen. It is believed from the results of the study that replacement of 30% of 5~13mm RCA brings desirable improvement in various aspect of concrete performance due to associated dense packing effect.

A Test of Correspondence Model with the HorizonRun 4 Simulation

  • Park, Jisook;Kim, Juhan;Park, Changbom;Kim, Sungsoo S.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.74.1-74.1
    • /
    • 2015
  • 'The one to one correspondence model' defines the relation between a dark matter halo (DM halo) and a galaxy. A basic assumption of this model is that a more massive DM subhalo hosts a brighter galaxy. In a more improved version of the model we may be able to assign a mock galaxy with a morphological type. In this study, we are building a mock galaxy catalog using massive halo merging trees from the Horizon Run 4. We test various merging models to calculate the merging time scale of a subhalo along its merging tree. And we obtain the halo mass functions for major subhalos and satellite subhalos, separately, and compare them with the observed luminosity functions of major galaxies and satellite galaxies from the SDSS group catalog. Furthermore, we are going to make a range of mock galaxy catalogs and investigate their properties, such as spatial distributions, environmental effects, and morphologies.

  • PDF

An Experimental Study on the Mock-up Test of Cold Weather Concreting Using Anti-freeze Agent and Insulating Form (내한제 및 단열거푸집을 이용한 한중콘크리트의 모의구조체 적용에 관한 실험 연구)

  • 김경민;손성운;김기철;오선교;한천구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.663-668
    • /
    • 2002
  • In this paper, insulating effects and strength development of concrete placed at mock up model structure are discussed using anti freezing agent and insulating forms. According to test results, concrete containing 8% of anti freezing agent shows lower freezing temperature, earlier setting time and higher strength development than plain concrete. As for the temperature history of mock up structures, when plain concrete is placed at euro form, the temperature drops to -4${\circ}$ before early 24 hours, and when concrete containing anti freeze agent at euro form, it to -3${\circ}$ before early 24 hours. Nevertheless, when concrete containing anti freeze agent is placed at insulating form, it does not go below zero, and the concrete containing anti freeze agent enhances higher strength development.

  • PDF

Strength Property and Mock-up Test of the High Performance Concrete with Emulsified Refined Cooking Oil (유화처리 정제식용유(ERCO) 사용에 따른 고성능 콘크리트의 Mock-up 및 강도특성)

  • Jo, Man-Ki;Kang, Byeong-Hoe;Lee, Dong-Gyu;Park, Kyu-Yeon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.136-137
    • /
    • 2014
  • In this study, fundamental performances of high strength concrete with ERCO has been analysed according to mock-up test. The following results could be made as the conclusion. For the fresh concrete, flowability and air content decreased with the addition of ERCO, and all the specimens satisfied the target range. For the strength properties, all the specimens with different nominal strength showed higher compressive srength than Plain which with 0% dosage of ERCO.

  • PDF

Autogenous Property and Mock-up Test of the High Performance Concrete with Emulsified Refined Cooking Oil (유화처리 정제식용유(ERCO) 사용에 따른 고성능 콘크리트의 Mock-up 및 자기수축특성)

  • Jo, Man-Ki;Kim, Jun-Ho;Lee, Dong-Gyu;Park, Kyu-Yeon;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.134-135
    • /
    • 2014
  • In this study, mock-up test for high strength concrete with ERCO has been carried to analyse the effect of autogenous shrinkage reducing of using ERCO. The following results could be made as the conclusion. Results of EIS were lower than 2.5 and showed good resistance for separation of materials. For the setting time, specimen with ERCO showed delay of setting comparing with Plain. For the autogenous shrinkage, as the generation of saponification, capillary pores inside the concrete were filled by soap and the autogenous shrinkage has been obviously decreased. It could be identified that using ERCO in high strength showed good effect on reducing autogenous shrinkage in high strength concrete.

  • PDF

The Mock-up Test of the Exposed Concrete by Applying the Flowing Concrete Method (유동화 공법을 적용한 노출 콘크리트 배합의 현장적용성에 관한 Mock-up Test)

  • Son, Ho-Jung;Park, Kyung-Taek;Hong, Seak-Min;Oh, Ch-Hyun;Han, Cheon-Goo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.165-167
    • /
    • 2011
  • This study is to evaluate the feasibility of the mix design for exposed concrete. Mock-up sized specimens were prepared, and a flowing concrete method was selected for placement. Results showed that the fluidity and air content of fresh concrete achieved target values, the compressive strength at 7 days was 27 MPa, and surface roughness was in the range of between around 1.53 and 1.68 ㎛, which was in the quality level. Therefore it is concluded that the proposed mix design for exposed concrete can be applied in practice.

  • PDF

Pyroshock measurement results of satellite mock-up for launch vehicle (발사체 목업(Mock-up) 위성의 파이로 충격 측정 결과)

  • Youn, S.H.;Jeong, H.K.;Seo, S.H.;Jang, Y.S.;Yi, Y.M.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.363-366
    • /
    • 2006
  • In general, pyrotechnic shock or pyroshock is generated during the operation of separation devices, which use explosives, such as pyrobolt, puronut, purocutter, linear shape charge, and so on. During the flight of launch vehicle, pyroshock is mainly produced at the events of satellite separation, fairing separation and stage separation. In this paper, characteristics of pyroshock are introduced in the first place and measured shock result data at the UMR of satellite mock-up during the separation tests of satellite and fairing are suggested. These results are compared with the suggested pyroshock test specification of satellite, and it finally confirms that the specification is reasonable for the qualification of satellite against pyroshock.

  • PDF